DOWNLOAD Sharp UP-600 / UP-700 (serv.man25) Service Manual ↓ Size: 2.63 MB | Pages: 51 in PDF or view online for FREE

Model
UP-600 UP-700 (serv.man25)
Pages
51
Size
2.63 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / UP600-700 Service Manual
File
up-600-up-700-sm25.pdf
Date

Sharp UP-600 / UP-700 (serv.man25) Service Manual ▷ View online

No.
NAME
PARTS CODE
PRICE
DESCRIPTION
1
1 hole clerk key
The key No.1 to No.12 ore supplied together with UP-700.
BH
Key No. 71
BH
Key No. 72
BH
Key No. 73
BH
Key No. 74
BH
Key No. 75
BH
Key No. 76
BH
Key No. 77
BH
Key No. 78
BH
Key No. 79
BH
Key No. 80
BH
Key No. 81
BH
Key No. 82
BH
Key No. 83
BH
Key No. 84
BH
Key No. 85
BH
Key No. 86
BH
Key No. 87
BH
Key No. 88
BH
Key No. 89
BH
Key No. 90
BH
Key No. 91
BH
Key No. 92
BH
Key No. 93
BH
Key No. 94
BH
Key No. 95
BH
Key No. 96
BH
Key No. 97
BH
Key No. 98
BH
Key No. 99
BH
Key No. 100
BH
Key No. 101
BH
Key No. 102
BH
Key No. 103
BH
Key No. 104
BH
Key No. 105
BH
Key No. 106
BH
Key No. 107
BH
Key No. 108
BH
Key No. 109
BH
Key No. 110
BH
Key No. 111
BH
Key No. 112
BH
Key No. 113
BH
Key No. 114
BH
Key No. 115
BH
Key No. 116
BH
Key No. 117
BH
Key No. 118
BH
Key No. 119
BH
Key No. 120
BH
Key No. 121
BH
Key No. 122
BH
Key No. 123
BH
Key No. 124
BH
Key No. 125
BH
Key No. 126
2
Mode key grip cover 
AX
For MA key only
3
Dripproof keyboard cover
BF
For UP-600 only
4
Dripproof mode switch cover
BA
5
Text preset key cover
BG
For UP-600 only
6
1 hole clerk kit
BP
For UP-600 only
7
Drawer separation kit
AP
5. SERVICE TOOLS
No.
NAME
PARTS CODE
PRICE
DESCRIPTION
1
Service key
AF
2
RS232 Loop Back Connector
BC
For RS232 D-SUB 9pin connector
3
RS232 modular Loop Back Connector
AZ
For RS232 RJ45 Modular jack connector
4
Expansion PWB for option board
BU
For ER-A5RS or ER-01EF
5
MCR test card
BL
For UP-E13MR
6
Keytop remover 
AX
For UP-600 only
7
Keytop inst. jig 
BB
For 2 X 2 key top
6. SUPPLIES
No.
NAME
PARTS CODE
PRICE
DESCRIPTION
1
Thermal roll paper
BA
5 Rolls / pack
2
Thermal roll paper (High preservatic type)
BD
5 Rolls / pack
3
Key sheet (Normal key layout)
AQ
For UP-700 only
4
Key sheet (Character key layout)
AG
For UP-700 only
5
Key sheet (Blank key layout)
AG
For UP-700 only
7. HOW TO USE SERVICE TOOLS
7-1. EXPANSION PWB : CKOG-6708RCZZ
External view
Purpose 1 : Used for servicing and repairing of options (such as the
and the ER-A5RS) wich are connected with the main
body option connector.
[Procedure 1]
Use an insulator base as shown in shaded section and perform serv-
icing.
To check the option I/F PWB from the solder side, connect the I/F
PWB to OPTCN2. To check from the parts side, connect to OPTCN3.
(Note) The option I/F PWB should be held horizontally so that no
excessive stress is applied to connecting section 
.
[Procedure 2]
Put a string between the pop up and the option PWB. Adjust the
length of the string so that the CKOG-6708RCZZ and the option PWB
are not binding. Then perform servicing.
7-2. MCR TEST CARD : UKOG-2357RCZZ
Used when executing the diagnostics of the UP-E13MR.
External view
UP-600/700
Main PWB
Expansion PWB
(CKOG-6708RCZZ)
ER-A5RS
PWB
Loop back connectors
UKOG-6705RCZZ
Base
A
UP-600/700
Main PWB
Expansion PWB
(CKOG-6708RCZZ)
ER-A5RS
PWB
Control ROM
Pop up
String
Loop back connectors
UKOG-6705RCZZ
CHAPTER 3. SERVICE PRECAUTION
1. IPL (Initial Program Loading) FUNCTION
1) INTRODUCTION
The application software of the UP-600/700 written in the flash ROM.
In the following cases, writing procedure of the application software
into the flash ROM is required
When the flash ROM is replaced with new one. The service part
flash ROM does not include the application software in it.
When IPL writing is required because of change in the software.
The service part ofthe main PWB unit includes the flash ROM with
the application software written in it, and there is no need for
writing the application software when replacing the main PWB unit.
2) IPL PROCEDURE
There are two ways of IPL procedures.
IPL from P-ROM
IPL from PC communication (Please refer the next section)
The detailed descriptions on the above procedures are given below.
3) IPL FROM P-ROM
Master ROM-1 : VHI27801RAP1A
Master ROM-2 : VHI27801RAQ1A
Before working on the installation, turn off the power switch on the
UP-600/700 and unplug the AC code from the AC outlet.
1. Insert a screwdriver into the slit on the right side of the lower
cabinet to remove the option RAM case.
2. IPL switch (SW301) on the IPL ROM PWB: Set the IPL switch
(SW301)  to ON position.
3. Install to the IC sockets on the IPL ROM PWB.
4. Turn on the power switch of the UP-600/700.
5. The following display is shown and the IPL procedure is started.
When the procedure is completed, the message of "Completed" is
shown.
6. Turn off the power switch of UP-600/700.
7. Remove to the IC sockets on the IPL ROM PWB.
8. IPL switch (SW301) on the IPL ROM PWB: Set the IPL switch
(SW301) to OFF position.
9. Perform the master reset.
ROM1
ROM2
ROM1
ROM2
on
off
SW301
IPL from PROM
Version check…
Erase …
IPL write start
26  27  28  29  2A  2B
2C  2D  2E  2F  30  31
38  39  3A  3B  3C  3D
3E  3F
Verify …
IPL write completed
32  33  34  35  36  37
Completed.
2. UP-600/700 Utility tools
1) OUTLINE
This Specification document describes the explanation about "POSU-
TILITYTOOL.EXE and "02FD.EXE".
"POSUTILITYTOOL.EXE"and "02FD.EXE" works on Windows 95/98
of PC and they have the following
Functions by connecting UP-600/700 with RS232.
POSUTILITYTOOL.EXE
: IPL of UP-600/700 Program Object
02FD.EXE
: All RAM Data Upload/Download
(PC software tool instead of the cur-
rent ER-02FD.)
2) ENVIRONMENT
PC and UP-600/700 are connected by RS232. 
Connect the CH2 port of the UP-600/700 to the RS-232 interface of
the PC.
RS232 Cable Connecting:
3) PROCEDURE
3) -1. POS UTILITY TOOL
No
Procedure on P.C. side
No
Procedure on UP-600/700 side
1
Install "POSUTILITYTOOL.EXE" on the P.C.
2
Turn OFF the power.
3
Select "IPL Mode".
Set "IPL Switch" (SW302) of UP-600/700 to "ON".
4
Turn ON the power.
5
Starting of "IPL Mode".
UP-600/700 shows
"IPL from Serial I/O"
6
Connect P.C. and UP-600/700 (CH2) via RS232. (Fig 1)
UP-600/700:CH2
PC
D-SUB 9pin - D-SUB 9pin
cable
D-SUB 9pin - modular RJ-45
conversion cable
(Open)
CD
D-sub 9pin
1
2
3
4
5
6
7
8
9
/CD
RD
SD
/ER
GND
/DR
/RS
/CS
/CI
RD
SD
/ER
GND
/DR
/RS
/CS
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
RD
SD
GND
CI
GND
S404
VCC
(+5V)
[UP-600/700]
Moduler RJ45
[PC]
D-sub 9pin
S403
on
off
SW302
on
off
IPL from Serial I/O
>>>>> USE FONT <<<<<
Helvetica/ Helvetica-Condensed/ Century-Schoolbook/ Symbol & OriginalFonts: (RingWorld2/RingFont2/Pa
Symbol/PartsCod)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Page of 51
Display

Click on the first or last page to see other UP-600 / UP-700 (serv.man25) service manuals if exist.