[12] Standard RAM test
1
Key operation
120 
 TL 
2
Functional description
Perform the following check for the standard RAM 32 KByte
SRAM. The memory contents should not be changed before and
after the check.
Perform the following processes for  memory address to be
checked (1C0000H~1DFFFFH).
PASS1: Save memory data.
PASS2: Write data "0000H."
PASS3:  Read and compare data "00H," write data "55H."
PASS4:  Read and compare data "55H," write data "AAH."
PASS5: Read and compare data "AAH."
PASS6: Restore the memory data.
If a compare error occurs in the check sequence PASS1-PASS6,
an error print is made. If no error occurs through all address, the
check ends normally.
The following address check is performed further.
Check point address = 1C0000H, 1C0001H
1C0002H, 1C0004H
1C0008H, 1C0010H
1C0020H, 1C0040H
1C0080H, 1C0100H
1C0200H, 1C0400H
1C0800H, 1C1000H
1C2000H, 1C4000H
1C8000H, 1D0000H
S
R A M
T S
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
Initialize the table pointer
Read check address from the
address table by pointer
sccess
Save data of check address
to the CPU register
Write data 55H to check
address
For check address other than
the current check address,
write AAH after saving 1-byte
data into the register
Is the
current check
address 55H?
Reset operation of saved data
Is the
operation comleted
for the other check
address?
Revise the table pointer
Is the
address table
completed?
End
YES
YES
YES
NO
Address
error
NO
NO
Check address
table
START
Table pointer
END
Operation flow
– 36 –
3
Check the following items:
Check the termination printout.
4
Test termination
The test terminates after printing the termination printout.
Termination printout:
 Normal termination
120 
  Abnormal termination
  Ex – – – – –
120 
@ @ @ @ @
 
X = 01: Data check error
02: Address check error
Note: When an error occurs, the error print is performed and the
check is terminated. The error occurrence address is shown in
hexadecimal at positions shown with 
@ @ @ @ @
.
[13] Standard ROM test
1
Key operation
130 
 TL 
2
Functional description
Sum check of the standard ROM (C00000H - C3FFFFH) is per-
formed. If the lower two digits of SUM is 10H, it is normal. 
3
Check the following items:
Check the printout after the test.
4
Test termination
The test automatically terminates with termination message.
Normal termination print
 
130 
 ROM
27020
@ @ @ @ @
 
@ @ @ @ @
 
Error termination print
  E – – – –  
130 
 ROM 
27020
@ @ @ @ @
 
@ @ @ @ @
 
Note:  "
@ @ @ @ @
" means the ROM version number. 
The underlined section (10 bytes) of code table is provided in
the ROM as a standard and the table content is always
printed. 
The table position is the upper 10 digits of the ROM address.
The check sum correction address is the last address -0FH.
Note: In the case of the ER-ROM, the ROM version number is dis-
played in the upper and the lower stages.
In the case of the MASK-ROM (future specification), the
MASK ROM code is displayed in the upper stage, and the
ROM version number is displayed in the lower stage.
 130 
 ROM
27020RAU1A  
RAU1A  
   
400 
[14] R/J printer dot pulse width adjustment
The dot pulse width adjust circuit is provided to control the width of
the current applied to the dot head of the printer, according to a
supply voltage fluctuation. 
When the circuit is changed with a new one for such as a repair work,
the dot pulse width needs to be adjusted using the 200K pot VR1.
Fig. 3-3
Dot pulse adjusting method
1. Turn power on.
2. Measure the voltage of the VP line between the fuse F1 and GND.
Use a digital voltmeter capable of measuring 100mV steps.
3. Set the MODE switch to the SRV position and start the diagnostic
program Job #150 with the next command procedure.
150 
 TL 
4. Adjust pulse width of PE at the test point TP1 as shown in the
graph in Fig.3. The pulse width of PE can be adjusted using the
200K pot VR1.
5. To terminate the diagnostic program, press any key.
FIg. 3-4
Fig. 3-5
Fig. 3-6
S
R O M
T S
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
+5V
+24V
+24V
R12
130KF
D6
1SS
   133
1
2
ZD3
E102
+5V
R15
3.3K
PE
TP
R14
62K
+24V
  3
  2
1
8
4
A
GL393
IC2
VR1
200K
R13
2K
ZD4
RD4.3EL1
Q4
C3198
TRG
R16
2K
R86
3.3K
C14
10000P
(2-7D)
(2-2D)
VR1
TP1
410
370
330
420
410
400
390
380
370
360
350
340
330
320
22
21.6
23
24
25
26 26.4
Transmission width (µ
s)
Drive voltage (V)
 ±3µs
(Allowance)
Pd
Pw
Pt
TRG
PE
Pw
Pt
4µsec
1000µsec
Pd is adjusted to 373±3µsec. when Vp is +24.0V.
– 37 –
[15] Option RAM test
1
Key operation
200 
 TL 
JOB
#NO.
RAM NO.
Memory to be
checked
Address area to be
checked
200
Option RAM
(main)
ER-02RA
1E0000H 
 1FFFFFH
ER-01RA
1E0000H 
 1E4FFFH
2
Content
The following check are performed for the optional RAM.
The following process is performed for memory addresses to be
checked. 
PASS1: memory data save
PASS2: Data "00H" write
PASS3: Data "00H" read and comparison, data "55H" write
PASS4: Data "55H" read and comparison, data "AAH" write
PASS5: Data "AAH" read and comparison
PASS6: Memory data restore
If a compare error is found in the check sequence from PASS1 to
PASS6, error print (error code E1) is performed. If there is no error
found to the end of the last address, the operation is completed
normally.
Address to be checked
1E0000H, 1E0001H
1E0002H, 1E0004H
1E0008H, 1E0010H
1E0020H, 1E0040H
1E0080H, 1E0100H
1E0200H, 1E0400H
1E0800H, 1E1000H
1E2000H, 1E4000H
1E8000H, 1F0000H 
 (For ER-02RA)
3
Check the following items.
Check the termination print. 
4
Test termination
The test terminates after printing the termination printout. 
Termination print
E01---01RA
200
(ER-01RA data check error)
E02---01RA
200
(ER-01RA address check error)
E01---02RA
200
(ER-02RA data check error)
E02---02RA
200
(ER-02RA address check error)
E01---
01RA
200
(ER-01RA normal end)
E02---
02RA
200
(ER-02RA normal end)
[16] Option ROM test
1
Key operation:
400 
 TL 
2
Functional description:
A sum check is done for the option ROM (Address hex C80000H
thru C9FFFFH.)
3
Check the following items:
Check the termination printout.
4
Test termination:
The test terminates after printing the termination printout.
Termination printout
 Normal termination
400 
 ROM
27010
@ @ @ @ @
 
@ @ @ @ @
 
  E – – – – –
400 
 ROM
27010
@ @ @ @ @
 
@ @ @ @ @
 
The underlined section must be the same as the standard ROM
test specification. (Refer to JOB #130.)
400 
 ROM
27010RAO1A
RAO1A 
O
R A M
T S
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
O
R O M
T S
S R V
DOT DISPLAY:
7-SEGMENT DISPLAY:
– 38 –
CHAPTER 6. DOWNLOAD
FUNCTION
1. General
RAM data can be transmitted in the following two methods.
Save the data before servicing as follows:
1
ECR 
 ECR
2
ECR 
 ER-02FD
Note:
The ONL lamp on the display blinks during IR transmission.
If the ONL lamp goes off during transmission, it shows that
transmission is interrupted by a shift in the optical axis and
retrying process is being performed. To resume
transmission, adjust the optical axis. If the ON lamp blinks,
transmission is resumed. 
2. Communication between ECRs
1) The pop-up display of the ER-A460/A470 is equipped with the IR
interface. Set the distance between IR interfaces within 75cm.
Communication between ECRs is available in the ASK system
and in the IRDA system. 
Note: Set the memory size (JOB #971) and the transmission
baud rate (JOB #903) in the receive side and the send side
identically. 
ECR to ECR
|
: Enable
: Disable
Baud rate (bps)
ASK
IrDA
  2400
|
|
  4800
|
|
  9600
|
|
 19200
|
|
 38400
|
|
 57600
|
|
115200
|
1. Baud rate (bps)
903-A
  2400
2
  4800
3
  9600
4
 19200
5
 38400
6
 57600
7
115200
8
2) Communication sequence
1
Set the receiving ECR ready to receive. 
2
Set the sending ECR.
3) Transmission status.
Description of error status
  1: Application error (Command error)
 2: Line error (DTR OFF)
 3: Application error (Parity error)
 4: Application error (Check sum error)
 5: Application error (Data size error)
 6: Hard ware error
 7: Power off error
10: Time out error
11: Application error (Transmit data size error)
12: Application error (Block sequence error)
13: Memory full error
4) Service reset the receiving ECR.
3. Communication between an ECR and
the ER-01FD/02FD
1) The ER-A460/A470 can perform IR communication by connecting
the IR interface (CE-IR2/IR4) to the FD unit (ER-01FD/02FD). The
transmission is made only in the ASK system. 
2) ER-01FD/02FD ROM replacement
To perform IR communication with the ER-01FD or the ER-02FD,
the control ROM must be replaced. 
New control ROM version for IR communication 
Version No.
Parts code
ER-01FD
R261C
VHI27256R261C
ER-02FD
RAG1D
VHI27256RAG1D
3) Connection between the ER-01FD/02FD and the CE-IR2/IR4
Make the connection cable and connect the FD unit and the IR
interface. 
Connection cable wiring
ECR
ECR
ECR
CE-IR2 or
CE-IR4
ER-02FD
TL
ABCD
0
903
Baud rate setting
x
TL
998
x
ST
: ASK system
: IRDA system
TL
996
X
All data
ST
X: SSP data = 0
: ASK system
: IRDA system
x
Frame Ground
1
SD
2
RD
3
RS
4
CS
5
DR
6
Signal Ground
7
ER
20
DB-25 MALE CONNECTOR
Frame Ground
TXD
RXD
RS
Signal Ground
DB-25 MALE CONNECTOR
1
2
3
4
5
6
7
20
ER-01FD/02FD side
CE-IR2/IR4 side
– 39 –