Sharp ER-A411 / ER-A421 (serv.man19) Driver / Update ▷ View online
ER-A411/A421 PCLINK
SHARP Confidential
4
4.2 Plural data set management
This software can manage plural data set by folder.
4.3 Multi- Language support
Each message and text of this software can be changed from English to other country language.
(e.g. French, German, Spanish and Swedish) by resource file for each language.
4.4 Character exchange support
Character code is different between PC and ECR.
This software supports exchanging characters.
5 Installation
Software installation is by copying the program files. (not use installer)
Software un-installation is also by deleting the program files. (not use un-installer)
That means the setting data is not stored on registry, stored in setting files and stored in same folder as
the data.
List of program files
for XE-A207
for XE-A217
PC-LINK_A207V.exe
PC-LINK_A217V.exe
CustomControlLibrary.dll
CustomControlLibrary.dll
ECR_Lib.dll
ECR_Lib.dll
EcrDataCtrl.dll
EcrDataCtrl.dll
ELMid.dll
ELMid.dll
pictcnv.dll
pictcnv.dll
logoconv.ini
logoconv.ini
de/CustomControlLibrary.resources.dll de/CustomControlLibrary.resources.dll
de/PC-LINK_A207V.resources.dll
de/PC-LINK_A207V.resources.dll
de/PC-LINK_A217V.resources.dll
es/CustomControlLibrary.resources.dll es/CustomControlLibrary.resources.dll
es/PC-LINK_A207V.resources.dll
es/PC-LINK_A207V.resources.dll
es/PC-LINK_A217V.resources.dll
fr/CustomControlLibrary.resources.dll fr/CustomControlLibrary.resources.dll
fr/PC-LINK_A207V.resources.dll
fr/PC-LINK_A207V.resources.dll
fr/PC-LINK_A217V.resources.dll
sv/CustomControlLibrary.resources.dll sv/CustomControlLibrary.resources.dll
sv/PC-LINK_A207V.resources.dll
sv/PC-LINK_A207V.resources.dll
sv/PC-LINK_A217V.resources.dll
for XE-A307
PC-LINK_A307V.exe
PC-LINK_A421V.exe
CustomControlLibrary.dll
ECR_Lib.dll
EcrDataCtrl.dll
ELMid.dll
pictcnv.dll
logoconv.ini
de/CustomControlLibrary.resources.dll
de/PC-LINK_A307V.resources.dll
de/PC-LINK_A421V.resources.dll
es/CustomControlLibrary.resources.dll
es/PC-LINK_A307V.resources.dll
es/PC-LINK_A421V.resources.dll
fr/CustomControlLibrary.resources.dll
fr/PC-LINK_A307V.resources.dll
fr/PC-LINK_A421V.resources.dll
sv/CustomControlLibrary.resources.dll
sv/PC-LINK_A307V.resources.dll
sv/PC-LINK_A421V.resources.dll
ER-A411/A421 PCLINK
SHARP Confidential
5
6 Each Functions
6.1 Start up
1. ECR data is automatically loaded that are saved at the last time.
2. If there is no ECR data on the PC, default data is set as follows.
Item
Default
DEPT
No record is created.
PLU/EAN
PLU/EAN is not created.
LOGO
No default data
LOGO TEXT
All text are filled by space.
VAT ID
0
3. Dept. screen is always displayed just after start up.
4. This software cannot run a plural number at the same time on the same PC.
6.2 Termination
1. ECR data is saved automatically into a folder that has been selected.
2. Window position and size is saved.
Window will be shown in same position and size at next time.
The above data (position, size, setting data) is recorded in the following file and folder.
File name
A207: setting207.xml
A217: setting217.xml
A307: setting307.xml
setting421.xml
A217: setting217.xml
A307: setting307.xml
setting421.xml
Folder name
XP : Document and Settings¥(user name)¥Application Data¥PC_TOOL¥Temp
Vista: Users¥(user name)¥AppData¥Roaming¥PC_TOOL¥Temp
7 : Users¥(user name)¥AppData¥Roaming¥PC_TOOL¥Temp
7 : Users¥(user name)¥AppData¥Roaming¥PC_TOOL¥Temp
8 : Users¥(user name)¥AppData¥Roaming¥PC_TOOL¥Temp
ER-A411/A421 PCLINK
SHARP Confidential
6
6.3 Title bar
Program title is always displayed on title bar.
"PC-LINK for XE-A207" is displayed for XE-A207.
"PC-LINK for XE-A217" is displayed for XE-A217.
"PC-LINK for XE-A307" is displayed for XE-A307.
"PC-LINK for ER-A411/A421" is displayed.
"PC-LINK for XE-A217" is displayed for XE-A217.
"PC-LINK for XE-A307" is displayed for XE-A307.
"PC-LINK for ER-A411/A421" is displayed.
6.4 Menu bar
This software contains following menu items.
Title
List
Contents
File(F)
Open(O) ...
You can select the folder which the data base are stored.
Export/Import(T) ...
Control SD data: Export and Import ECR data to/from SD card.
Setting(S) ...
You can set general setting of this software.
Exit(X)
Terminate the software.
Exec(E)
Receive(R) *1 Receive from ECR via RS232.
Send(S) *2 Send to ECR via RS232.
Record(R)
New(N)
You can add new PLU/EAN or Department code.
Delete(D)
You can delete PLU/EAN or Department code.
About(A)
This shows software name and version information.
*1: At "LOGO" tab, "Receive(R)" menu is not displayed.
At "ALL RAM" tab, "Backup(B)" menu is displayed instead of "Receive(R)" menu.
*2: At "DEPT" tab, "Select and Send(S) ..." menu is displayed instead of "Send(S)" menu.
At "PLU/EAN" tab, "Select and Send(S) ..." menu is displayed instead of "Send(S)" menu.
At "ALL RAM" tab, "Restore(R)" menu is displayed instead of "Send(S)" menu.
ER- A4 1 1 / A4 2 1
ER-A411/A421 PCLINK
SHARP Confidential
7
6.5 File
ER- A4 1 1 / A4 2 1
This menu item can be operated in case of any TAB is selected.
Open
Load ECR data from selected folder.
Selected folder is set as current DATA FOLDER.
Export/Import
The following window is shown after selecting this menu item.
PCLINK lists up the drives that have the folder ¥SHARP¥
ECRXXX16
¥ on its root.
PCLINK list up the folders under ¥SHARP¥
ECRXXX16
¥ of the selected drive.
Then, following function can be executed.
Button
Functionality
Export
Programming data is saved into specified folder on SD CARD.
Import
Programming data is loaded from specified folder on SD CARD.
New Folder
Create a new user folder on SD CARD.