DOWNLOAD Sharp ER-A410 / ER-A420 (serv.man4) Service Manual ↓ Size: 3.56 MB | Pages: 53 in PDF or view online for FREE

Model
ER-A410 ER-A420 (serv.man4)
Pages
53
Size
3.56 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ERA410 420 Programming Manual
File
er-a410-er-a420-sm4.pdf
Date

Sharp ER-A410 / ER-A420 (serv.man4) Service Manual ▷ View online

ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 22
[JOB#2643]
SLIP TEXT PROGRAMMING
1 BLOCK MAX. 24 CHARACTERS
[JOB#2646]
PAYEE NAME FOR ENGLISH CHECK PROGRAMMING
1 BLOCK MAX. 21 CHARACTERS
[JOB#2680]
PROGAMMING FOR EXCHANGE DRAWER
MRS = 0
[JOB#2681]
EURO FUNCTION
MRS = 000
[JOB#2682]
EURO DATE
Timing of changing the currency between LOCAL and EURO
The date entry format complies with SRV#912_A.
In case of date/time setting is 0, EURO date/time function is not work.
MRS = 000000
[JOB#2683]
EURO TIME (hour only)
Timing of changing the currency between LOCAL and EURO
MRS = 00
[JOB#2689]
POWER SAVING
MRS = 0030 
[JOB#2690]
THE ASSIGNMENT OF RS232 FUNCTION BY EACH DEVICES
X: Position code = 1 to 3
MRS = “Space”
“Space”
“Space”
X: Position code =1 to 2
MRS = “Space”
“Space”
X: DRAWER No.
X
Non
0
#1
1
#2
2
A: Automatic converting the unit price at EURO
A
Yes
0
No
1
B: The EURO CHANGE JOB at EURO DATE/TIME
B
Compulsory
0
Non-compulsory
1
C: EX1 Fractional treatment
C
Raising to unit
0
Rount off (4-DOWN, 5-UP)
1
2643
Characters
No change
SBTL
CA/AT
@/FOR
@/FOR
Position code
X
2646
Characters
No change
SBTL
TL
Position code
X
2680
X
0
TL
2681
ABC
TL
0
XXXXXXXX: DATE
(DATE) YYYYMMDD (Year-month-day) or
DDMMYYYY (Day-month-Year) or
MMDDYYYY (Month-day-Year)
[YYYY: 2000-2099] [MM: 01-12] [DD: 01-31]
HH: Hour (0-23)
X: POWER SAVING function when a time is displayed
X
Yes
0
No
1
YYY: POWER SAVING TIME to POWER OFF = 001-254 (minutes)
or 999 (Inhibit)
X: 1
MRS = 0000
A: Channel No. for on-line
A
Not connect
0
RS port 1
1
RS port 2
B, C, D:  Not used (Fixed at “000”)
2682
XXXXXXXX
0
TL
2683
HH
0
TL
2689
XYYY
TL
2690
ABCD
0
X
ST
TL
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 23
*
 EFT FUNCTION always uses RS port 2.
*
DATA BACK UP FUNCTION always uses RS port 1.
[JOB#2711]
TAX RATE PROGRAMMING
(LOWER TAX LIMIT is invalid in VAT system.)
MRS = DELETE
[JOB#2900]
<CAUTION>
(This JOB must be performed at X2/Z2 mode position.)
AUTO KEY SETTING
(Auto key function)
• This machine has [AUTO] key which can be programmed by the fol-
lowing key-sequence.
•  When [AUTO] key is depressed, the machine works the same as the
programmed key-sequence programed.
<Example>
(X2/Z2)
(REG)
(X2/Z2)
(REG)
X: 2 Not used (Fixed at “0000“)
MRS = 0000
X: 3
MRS = 0000
A: Not used (Fixed at “0”)
B: Channel No. for slip printer
B
Not connect
0
RS port 1
1
RS port 2
2
C, D: Not used (Fixed at “00”)
(Note: When the ER-03EF is connected, RS port 2 cannot be used
for other purposes.)
(Note: If RS port 1 is not used by DATA BACKUP FUNCTION, it is
available for other purposes by setup.)
A: TAX 1 PROGRAMMING = 1
TAX 2 PROGRAMMING = 2
TAX 3 PROGRAMMING = 3
TAX 4 PROGRAMMING = 4
X: SIGN
X
+
0
-
1
YYY. YYY:
RATE = 0.0000 to 100.0000 %
ZZZZZ: LOWER TAX LIMIT = 0 to 99999
2711
XYYY.YYYY
A
TAX No.
TL
ST
TL
ST
TL
ST
Sign & TAX rate
0
ZZZZZ
Lower TAX limit
for ADD-ON TAX
0
Delete
Delete
Delete
(Rate = 0%,  
Lower TAX limit = 0)
(Lower TAX limit = 0)
2900
(Free key)
AUTO
Max.25
TL
AUTO2
AUT O3
AUTO4
AUT O5
AUTO
AUT O2
AUTO3
AUT O4
AUTO5
Delete
AUTO10
AUTO10
2900
AUTO
PLU1
100
DEPT2
AUTO
TL
Key entry
R/J
Display
Comment
AUTO
PL000001   
*
1.10
DEPT02      
*
1.00
PL0000001
same as                 entry
PLU1
1.10
1
10
100
DEPT02
1.10
same as                 entry
1
same as                 entry
0
same as                 entry
0
same as                 entry
DEPT2
2900
AUTO2
100
AUTO2
TL
TL
Key entry
R/J
Display
Comment
DEPT 1
DEPT01
DEPT01
1.00
100
CHANGE
0.00
same as         entry
1
same as         entry
0
same as         entry
0
same as         entry
TL
AUTO 2
*
1.00
***
TOTAL
*
1.00
CASH
*
1.00
CHANGE
*
0.00
10
1
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 24
[JOB#2990] 
THERMAL PRINTER PROGRAMMING
MRS = 50
[JOB#6110]
RS-232C TERMINAL No.
XXXXXX: Terminal number
MRS = 000001
[JOB#6111]
RS-232C TRANSMISSION
MRS = 00
[JOB#6112]
RS-232C FUNCTION SELECTING
(
*
) Data value “3/2/1/0” is reserved.
Note: The value of baud rate is used at Online communication and
Print data function.
It is not used at Data back up function (SRV#996, SRV#998).
MRS = 06
[JOB#6113]
RS-232C PROGRAMMING
XXX: Start code (000-127)
YYY: End code (000-127)
MRS = 002013
[JOB#6115]
RS-232C TIME OUT
XXX: Time out time (1-255 sec)
MRS = 007
[JOB#6220]
PRINT DATA SENDING
MRS = 000
ZZ: Selecting of light and shade
ZZ
Lighter than standard
00
Standard (90% for printer standard)
50
Darker than standard
99
A: Sending of CI signal
A
No
0
Yes
1
B: Transmission line form
B
Full duplex system
0
Half duplex system
1
A: Print data
A
Data download and upload
0
Print data send
1
B: RS-232C Baud rate
B
4800bps
4
9600bps
5
19200bps
6
38400bps
7
0
2990
ZZ
TL
6110
XXXXXX
0
TL
6111
AB
0
TL
6112
AB
0
TL
A: Sending of DR signal
A
Yes
0
No
1
B: Sending of CS signal
B
Yes
0
No
1
C: Sending of all print data
C
Disable
0
Enable
1
6113
XXXYYY
0
TL
6115
XXX
TL
6220
ABC
0
TL
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 25
3. PROGRAMMING BY DIRECT KEY
1) DEPT UNIT PRICE
MODE: PGM1, PGM2
If a price is set for a department which amount entry type is “INHIBIT” or
“OPEN”, its amount entry type is set as below automatically.
MRS = 0
2) (-) PRESET AMOUNT
MODE: PGM, PGM2
MRS = 0
3) DEPT FUNCTION PROGRAMMING
MODE: PGM2
YY: Department Code (01-99)
XXXXXX: Unit price (Max. 6 digits)
“PRESET”
”INHIBIT”
“OPEN & PRESET”
1
 ”OPEN”
YY: Department Code (01-99)
XXXXXX: Unit price (Max. 6 digits)
DPT n
0
XXXXXX
0
XXXXXX
YY
ST
TL
DEPT#
(-) n
0
XXXXXX
TL
YY: Department code (01-99)
A: Taxable 4
A
No
0
Yes
1
B: Taxable 3
B
No
0
Yes
1
C: Taxable 2
C
No
0
Yes
1
D: Taxable 1
D
No
0
Yes
1
E: ITEM VP
E
Non-compulsory
0
Compulsory
1
F: REGISTRATION TYPE
F
NORMAL
0
SICS
1
SIF
2
G: AMOUNT ENTRY TYPE
G
Inhibit
0
Open only
1
Preset only
2
Open & Preset
3
H: HALO Mantissa = 0 to 9
I: HALO Exponent = 0 to 8
H and I indicate A x 10
B
Except the value A and B, any amount over 99999999 can
not be entered.
J: Commission group = 0 to 9
KK: Department group = 00 to 14
Group 01 to 09 : Plus department
Group 10 : Minus department
Group 11 : Plus HASH department
Group 12 : Minus HASH department
Group 13 : Plus BR department
Group 14 : Minus BR department
MRS =  000100118001
(TAXABLE 1, VP Non-compulsory, NORMAL, Open only,
HALO = 17, Commission =0, Group =01)
DPT n
0
ABCDEFGHIJKK
0
ABCDEFGHIJKK
YY
TL
DEPT#
Page of 53
Display