DOWNLOAD Sharp ER-A410 / ER-A420 (serv.man4) Service Manual ↓ Size: 3.56 MB | Pages: 53 in PDF or view online for FREE

Model
ER-A410 ER-A420 (serv.man4)
Pages
53
Size
3.56 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ERA410 420 Programming Manual
File
er-a410-er-a420-sm4.pdf
Date

Sharp ER-A410 / ER-A420 (serv.man4) Service Manual ▷ View online

ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 18
G: Subtotal void in REG mode
G
Enable
0
Disable
1
H: Refund VP
H
Non compulsory
0
Compulsory
1
XX: 2
MRS = 00000000
A: The first last item void
A
Enable
0
Disable
1
B: PLU SHIFT LEVEL reset
B
Auto
0
Manual
1
C: PLU LEVEL SHIFT
C
REG & MGR
0
MGR only
1
D: Printing of the number of purchases
D
No
0
Yes
1
E: Time print
E
Yes
0
No
1
F: Printing of journal
F
Full print
0
Journal select
1
G: Item VP
G
Enable
0
Disable
1
H (
) VP
H
Non compulsory
0
Compulsory
1
XX: 3
MRS = 00000000
A: Not used (Fixed at “00”)
B: Zero skip in Clerk report
B
Yes
0
No
1
C: Zero skip in Cashier report
C
Yes
0
No
1
D: Zero skip in Transaction report
D
Yes
0
No
1
E: Zero skip in Dept. report
E
Yes
0
No
1
F: Zero skip in PLU report
F
Yes
0
No
1
G: Zero skip in Hourly report
G
Yes
0
No
1
H: Zero skip in Daily net report
H
Yes
0
No
1
XX:  4
MRS = 00000000
A, B: Not used (Fixed at "00")
C: Vat/Tax amount printing on R/J
C
Yes
0
No
1
D: Taxable amount printing on R/J
D
Yes
0
No
1
E: Net amount printing on R/J
E
Yes
0
No
1
F, G: Not used (Fixed at “00”)
H: PLU SHIFT LEVEL AUTO reset timing. 
(Available when “X = 2, B = 0: PLU SHIFT LEVEL
reset = AUTO”)
H
1 item
0
1 receipt
XX: 5
MRS = 00000000
A, B, C: Not used (Fixed at “000”)
D: VAT shift system
D
By cashier
0
By shift key
1
E: PLU PRICE SHIFT
E
By shift key
0
By cashier
1
F: PLU PRICE SHIFT
F
REG & MGR
0
MGR only
1
G: PLU PRICE LEVEL reset
G
Auto
0
Manual
1
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 19
[JOB#2617]
PROGRAMMING OF THE TIME INTERVAL FOR THE DRAWER
ALARM
MRS = 000
H: PLU PRICE LEVEL auto reset timing 
( A v a i l a b l e   w h e n   “ P L U   P R I C E   L E V E L   r e s e t
=AUTO”)
H
1 item
0
1 receipt
1
XX: 6
MRS = 00000000
A: VAT/TAX AMOUNT PRINTING on SLIP/G.C.RCPT
A
Print
0
Not print
1
B: TAXABLE AMOUNT PRINTING on SLIP/G.C.RCPT
B
Print
0
Not print
1
C: NET AMOUNT PRINTING on SLIP/G.C.RCPT
C
Print
0
Not print
1
D: TIME PRINTING on SLIP/G.C.RCPT
D
Print
0
Not print
1
E, F, G, H: Not used (Fixed at "0000")
XX: 7
MRS = 00000000
A, B: Not used (Fixed at “00”)
C: No sale in REG mode
C
Enable
0
Disable
1
D: Finalization in REG mode when ST is zero
D
Enable
0
Disable
1
E, F, G, H: Not used (Fixed at "0000")
XX: 8
MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 9
MRS = 00000000
A: Not used (Fixed at “0”)
B: EXCHANGE 1 calculation method
B
Multiplication
0
Division
1
C: CHECK, CREDIT operation for EX1
C
No
0
Yes
1
D: Printing of EX1 amount for Total and Change
D
No
0
Yes
1
E: Printing of EX1 amount for Total VP
E
No
0
Yes
1
F. G: Not used (Fixed at "00")
H: Footer graphic LOGO printing at the end of receipt
H
No
0
Yes
1
XX: 10
MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 11
MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 12
MRS = 00000000
A, B, C, D, E, F, G, H: Not used (Fixed at “0000000”)
XX: 13
MRS = 00000000
A: Credit totalizer update if RA/PO finalized by Credit
key
A
No
0
Yes
1
B: Separator line in report
B
1 line
0
Separator line
1
C: Link  PLU print format in REG/MGR mode
C
Each PLU
0
Parent PLU text with total amount
1
D, E, F, G, H: Not used (Fixed at "00000")
XXX: 0  ~ 255 sec
2617
XXX
0
TL
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 20
[JOB#2619]
HOURLY REPORT (Starting time)
MRS = 000
ex)
X1 Hourly report (#160) (30 min, start time = 7)
[JOB#2620]
STACK REPORT
[
**
]
Max. 70 step are programmable. “1 step” means the memory size used
for one no range type JOB#.
The RANGE type JOB# means “8 steps”.
For example)
The memory size for programming JOB#00, 20 and 50 is 10 steps. 
(ie. 1 step for JOB#00, 8 step for JOB#20, and 1 step for JOB#50.)
[JOB#2630, 2631, 2632]
SECRET CODE PROGRAMMING
*
If “0” is entered, “compulsory secret code entry” is canceled.
MRS = 0
A:
 Memory format
A
30 minutes (24 hour)
0
60 minutes (24 hour)
1
BB: Starting time (hour):
00~23
2619
ABB
0
TL
2619
007
TL
#160
      7:00
         (DATA)
      7:30
         (DATA)
 SUBTOTAL
         (DATA)
          |
    23:30
         (DATA)
 SUBTOTAL
         (DATA)
      0:00
         (DATA)
      0:30
         (DATA)
 SUBTOTAL
         (DATA)
          |
      6:30
         (DATA)
 SUBTOTAL
         (DATA)
24 hours started
from 7:00
XX: JOB#
SSSSSS: Start code
EEEEEE: End code
JOB#
REPORT NAME
TYPE
00
General
10
DEPT.
13
DEPT. All group
20
PLU
RANGE
24
PLU stock
RANGE
27
PLU zero sales
29
PLU category
RANGE
30
Transaction
31
CID
32
Commission sales
40
All clerk
50
All cashier
60
Hourly
ALL
RANGE (only X report)
70
Daily net
80
PBLU
RANGE
82
BALANCE
#2630: PGM1 mode
#2631: X1/Z1 mode
#2632: X2/Z2 mode
2620
XX
SSSSSS
EEEEEE
All delete
No range
ST
TL
2630
2631
2632
XXYY
0
TL
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 21
[JOB#2641]
MESSAGE TEXT PROGRAMMING
A message is 12 CHARACTERS
No.14~21 are all reserved.
No.38~47 are all reserved.
No.49~66 are all reserved.
No.68~71 are all reserved.
No.77~80 are all reserved.
[JOB#2642]
VP TEXT PROGRAMMING
1 BLOCK MAX. 24 CHARACTERS
XX: Message No. = 1 to 99
No.
Description
MRS
1
Registration error
ENTRY ERROR
2
Misoperation error
MISOPRATION
3
Desired code is not programmed yet.
NO RECORD
4
(Reserved)
5
Secret code error
SECRET CODE
6
(Reserved)
7
Memory is full
MEMORY FULL
8
Insert slip paper
INSERT SLIP
9
The cashier has entered  a code for
which he or she is not authorized.
NO AUTHORITY
10
Stock is empty
OUT OF STOCK
11
Compulsory of pushing the SBTL key
SBTL COMPUL.
12
Compulsory of tendering
TEND COMPUL.
13
PBLU entry compulsory
PB COMPUL.
No.
Description
MRS
22
Overlapped cashier error
CASHIER ERR.
23
Cashier resetting over error
ENTRY ERR CA
24
(Resaved)
25
(Resaved)
26
(Resaved)
27
Power off
POWER OFF
28
(Resaved)
29
(Resaved)
30
(Resaved)
31
Non ADD code entry compulsory
# COMPULSORY
32
The cashier/clerk key is not assigned. NOT ASSIGNED
33
(Resaved)
34
Overflow limitation
OVER LIMIT.
35
The open price entry is inhibited.
INH. OPEN PR
36
The unit price entry is inhibited
INH. UNIT PR
37
The direct non-tendering finalization
after previous tender entry is inhibited.
NOT NON-TEND
No.
Description
MRS
48
(Reserved)
No.
Description
MRS
67
REG buffer full
BUFFER FULL
2641
Characters
XX
Message No.
No change
ST
TL
No.
Description
MRS
72
EFT ERROR
EFT ERROR
73
EFT BREAK
EFT BREAK
74
(Reserved)
75
(Reserved)
76
Close drawer error
CLOSE DRAWER
No.
Description
MRS
81
Enter secret code
ENTR SECRET#
82
(Reserved)
83
(Reserved)
84
DATA BACKUP send success
SEND OK
85
DATA BACKUP receive success
RECEIVE OK
86
DATA BACKUP communication error
COM. ERROR
87
DATA BACKUP data format error
DATA ERROR
88
DATA BACKUP timeout error
TIME OUT
89
(Reserved)
90
(Reserved)
91
(Reserved)
92
(Reserved)
93
(Reserved)
94
(Reserved)
95
EURO CHANGE COMPULSORY
EURO CHANGE
96
(Reserved)
97
(Reserved)
98
(Reserved)
99
(Reserved)
X: Position code = 1 to 3
MRS = “
“FOR DEPOSIT ONLY”
2642
Characters
No change
SBTL
CA/AT
@/FOR
@/FOR
Position code
X
Page of 53
Display

Click on the first or last page to see other ER-A410 / ER-A420 (serv.man4) service manuals if exist.