DOWNLOAD Sharp ER-A410 / ER-A420 (serv.man4) Service Manual ↓ Size: 3.56 MB | Pages: 53 in PDF or view online for FREE

Model
ER-A410 ER-A420 (serv.man4)
Pages
53
Size
3.56 MB
Type
PDF
Document
Service Manual
Brand
Device
ECR / ERA410 420 Programming Manual
File
er-a410-er-a420-sm4.pdf
Date

Sharp ER-A410 / ER-A420 (serv.man4) Service Manual ▷ View online

ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 6
2. PROGRAMMING
[JOB#1110]
PROGRAMMING OF DEPT. PRICE
If a price is set for a department which amount entry type is “INHIBIT” or
“OPEN”, its amount entry type is set as below automatically.
MRS = 000000
[JOB#2110]
PROGRAMMING OF DEPT. FUNCTION
MRS = 001
[JOB#2111]
DEPT. TAX STATUS PROGRAMMING
MRS = 0000
[JOB#2112]
DEPT. HALO (limit) preset
*
Items A and B indicate A 
u
 10
B
. Any amount below that value is
enable within 99999999.
MRS = 18
XX: DEPT-CODE = 01~Max number of DEPT.
YYYYYY: PRICE = 0~999999
“PRESET”
1
 “INHIBIT”
“OPEN&PRESET”
1
 “OPEN”
XX: DEPT. code = 01~Max number of DEPT.
A: Item validation printing
B
Non compulsory
0
Compulsory
1
B: SICS Function
E
Normal
0
Single item cash sale
1
Single item finalize
2
C: Amount entry type
G
Inhibited
0
Open
1
Preset
2
Open and preset
3
1110
YYYYYY
XX
0
price
DEPT. CODE
For next code
TL
ST
2110
XX
DEPT. CODE
ABC
For next code
0
TL
ST
XX: DEPT. CODE = 01~Max number of DEPT.
A: Taxable 4
D
Non taxable
0
Taxable
1
B: Taxable 3
E
Non taxable
0
Taxable
1
C: Taxable 2
F
Non taxable
0
Taxable
1
D: Taxable 1
G
Non taxable
0
Taxable
1
XX: DEPT. CODE = 01~Max number of DEPT.
A: Mantissa (HALO) = 0~9
B: Exponent (HALO) = 0~8
2111
XX
DEPT. CODE
ABCD
For next DEPT.
0
ST
TL
2112
AB
XX
DEPT. CODE
For next DEPT.
0
TL
ST
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 7
[JOB#2114]
DEPT. TEXT PROGRAMMING
Characters: Max. 16Characters
Characters can be entered by using character keys or numeric keys.
The key entry sequence for entering one character by numeric key is as
follows.
MRS = DPT. X_X_
[JOB#2115]
COMMISSION GROUP PROGRAMMING
[JOB#2116]
PROGRAMMING OF DEPT. GROUP
MRS = 01
A selection of the group “Hash” is inhibited when the hash return func-
tion is programmed as disabled in SRV mode.
[JOB#2119]
DEPARTMENT CODE DEFINITION FOR DIRECT DEPT. KEYS
DEPT. code is assigned to the key no. which has been programmed in
JOB#951 programming.
[JOB#1200]
CREATING/ASSIGNING PLUS AND THE ASSOCIATED DEPARTMENTS.
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
MRS = 01
[JOB#1210] 
PLU UNIT PRICE PROGRAMMING
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
If a price is set for a department which amount entry type is “INHIBIT”
or “OPEN”, its amount entry type is set as below automatically.
MRS = 0
XX: DEPT. CODE = 01~Max number of DEPT.
XXX 
3
 00 KEY
XXX: CHARACTER CODE (3 DIGITS)
XX: DEPT. CODE = 01~Max number of DEPT.
A: Group No. = 0~9
XX: DEPT. code = 01~Max number of DEPT.
YY: Group No. = 01 ~ 14
Group No.
Group name
01~09
Plus department
10
Minus department
11
Plus HASH department
12
Minus HASH department
13
Plus BR department
14
Minus BR department
2114
XX
DEPT. CODE
Character key
For next code
No change
ST
TL
2115
XX
DEPT. CODE
A
For next code
0
TL
ST
2116
XX
DEPT. CODE
YY
For next code
TL
ST
XXX: Key No.
YY: DEPT. CODE
XXXXXX: PLU code = 1~999999
YY: DEPT. code = 01~Max number of DEPT.
XXXXXX: PLU CODE = 1~999999
YYYYYY: Amount = 0~999999
“PRESET”
1
 “INHIBIT”
“OPEN&PRESET”
1
 “OPEN”
2119
XX
YY
X
KEY No.
inhibit
ST
TL
For next code
1200
XXXXXX
PLU code
YY
0
ST
TL
For next code
1210
XXXXXX
PRICE1
PRICE2
YYYYYY
0
0
ST
YYYYYY
ST
TL
Code increment
Code entry
CL
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 8
[JOB#1211]
PLU BASE Q’TY PROGRAMMING
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
MRS = 0
[JOB#2215]
COMMISSION GROUP PROGRAMMING
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
MRS = 0
[JOB#1220]
PROGRAMMING OF PLU STOCK (ADD)
The stock value entered is added to the PLU stock counter.
MRS = 0
[JOB#1221]
PROGRAMMING OF PLU STOCK (SUB)
The stock value entered is subtracted the PLU stock counter.
MRS = 0
[JOB#1222]
PROGRAMMING OF PLU SOTCK (OVERWRITE)
The stock value entered is overwritten the PLU stock counter.
MRS = 0
[JOB#2210]
PLU function programming
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
MRS = 2
[JOB#2211]
PLU TAX STATUS PROGRAMMING
XXXXXX: PLU code = 1~999999
ZZ: Base quantity = 00~99
XXXXXX: PLU code = 1 ~ 999999
A: Group No. = 0 ~ 9
XXXXXX: PLU code (1 to 999999)
YYYYYYY: STOCK VALUE = 1 to 9999999
XXXXXX: PLU code (1 to 999999)
YYYYYYY: STOCK VALUE = 1 to 9999999
1211
ZZ
XXXXXX
PLU CODE
For next code
0
TL
ST
2215
A
XXXXXX
0
PLU code
For next code
ST
TL
1220
YYYYYYY
XXXXXX
PLU code
For next code
TL
ST
1221
YYYYYYY
XXXXXX
PLU code
For next code
TL
ST
XXXXXX: PLU code (1 to 999999)
YYYYYYY: STOCK VALUE = 0 to 9999999
XXXXXX: PLU code = 1~999999
A:  Amount entry type
A
 Inhibited
 0
 Open
 1
 Preset
 2
 Open and preset
 3
 Delete
 4
XXXXXX: PLU code = 1~999999
A:  Sign
 A
 
+
 
0
 
 1
B:  Taxable 6
 B
 Non taxable
 0
 Taxable
 1
C:  Taxable 3
C
 Non taxable
 0
 Taxable
 1
1222
YYYYYYY
XXXXXX
PLU code
For next code
TL
ST
0
2210
A
XXXXXX
0
PLU code
For next code
ST
TL
2211
XXXXXX
PLU code
ABCDE
0
For next code
TL
ST
ER-A410/ER-A420
PROGRAM (PGM2/PGM1) MODE
2 – 9
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
MRS = 00000
[JOB#2214]
PLU TEXT PROGRAMMING
Characters can be entered by using character keys or numeric keys.
The key entry sequence for entering one character by numeric keys is
as follows: 
If the record of entered PLU code is not in PLU file at this programming,
it will be created in PLU file.
MRS = PLXXXXXX
[JOB#2219]
PLU CODE DEFINITION FOR DIRECT PLU KEYS
MRS = STANDARD KEY LAYOUT
[JOB#2220]
LINKED PLU PROGRAMMING
When the “ST” key is pressed without entering any number as the first
PLU code (YYYYYY), the previous data is cleared.
PLU code should already be defined when they are used in program-
ming here.
MRS = 0
[JOB#2221]
SET PLU (COMBO) programming
When the “ST” key is pressed without entering any number as the first
PLU code (YYYYYY), the previous data is cleared.
PLU code should already be defined when they are used in program-
ming here.
MRS = 0
[JOB#2230]
PLU CODE PROGRAMMING (range)
It changes the data of PLU records only which exists in PLU file in the
entered range of PLU code.
D:  Taxable 2
D
 Non taxable
 0
 Taxable
 1
E:  Taxable 1
 E
 Non taxable
 0
 Taxable
 1
XXXXXX: PLU code (1 to 999999)
Characters: MAX. 16Characters
XXX 
3
 00 KEY
XXX: CHARACTER CODE (3 DIGITS)
*
First time
= LEVEL1
The others = Same as previous level
XX: Key No. (Assigned by SRV#951)
YYYYYY: PLU No. (1-999999)
2214
XXXXXX
Character key
For next code
No change
ST
TL
PLU code
No.
XXXXXX: PLU code = 1~999999 max.
YYYYYY: PLU code = 1~999999 max.
XXXXXX: Parent PLU code (1 to 999999 max.)
YYYYYY: Tied PLU code (1 to 999999 max.)
XXXXXX: Start PLU code = 1~999999
YYYYYY: End PLU code = 1~999999
ZZ: Dept. code = 1~Max number of DEPT.
2220
YYYYYY
XXXXXX
Max. 5 times
Delete or skip
PLU code
TL
ST
2221
YYYYYY
XXXXXX
Max. 5 times
TL
ST
Delete or skip
2230
YYYYYY
XXXXXX
PLU code
ZZ
PLU code
TL
ST
Change to the data
of start PLU
Page of 53
Display

Click on the first or last page to see other ER-A410 / ER-A420 (serv.man4) service manuals if exist.