SD-CX1H
– 24 –
ADJUSTMENT
fL: Low-range frequency
fH: High-range frequency
Signal generator: 400 Hz, 30%, AM modulated
• AM IF/RF
• Setting the Test Mode
When setting the tuner test mode, the frequencies are initialized
in the memory as shown in Table 24. Refer to the microcomputer
test mode function on pages 19 and 23.
If the initialization is executed, the frequencies registered by
the user are changed.
• FM Mute Level
FM Signal oscillator Frequency 400 Hz, 22.5 kHz
98.0 MHz
98.0 MHz
VR351
Input: SO301A
  (30 dB)
Output: Headphones
             terminal
TUNER SECTION
Adjusting Item
AM IF
T351 Indication of
IF wavefome 450 kHz
set must be 1,620 kHz
is set to max.
AM Band
fL: T306 (522 kHz)
fL: 1.3V 
±
 0.1V
 Coverage (Voltage Set Display of 522 kHz
fH: 8.5V 
±
 1.3V
of TP302 VT line)
(fH is only check)
AM Tracking
fL: T302 (990 kHz)
Set output of
Headphones terminal
to maximum.
Adjusting object
Adjusting method
Adjusting
method
Adjusting
object
Adjusting object
Adjusting
method
P01
  87.50 MHz
P06
   522 kHz
P02
108.00 MHz
P07
1,620 kHz
P03
  90.00 MHz
P08
   603 kHz
P04
106.00 MHz
P09
1,404 kHz
P05
  98.00 MHz
P10
   990 kHz
Figure 24-1 AM IF/RF
GND
AM Loop Antenna
AM signal oscillator
Loop Antenna
IF: Headphones
Frequency cover: TP301
Electric
Voltmeter
UNIT
Figure 24-4 Output Offset Lelel
GND
SO301A
Headphones
Terminal
UNIT
Electric
Voltmeter
FM signal oscillator
Figure 24-2 FM Mute Level
Figure 24-3 ADJUSTMENT POINT
Preset.
memory
FM
frequency
AM
frequency
Preset.
memory
• To erase the registered broadcast stations
When exiting from the test mode, all preset data is erased.
Table 24
1-BIT AMP. SECTION
 1-bit amp. output offset voltage adjustment
Applying AC 100V, adjust the VRA100/101 so that the voltage
between + and - of the speaker output terminal (BIA110) is
within 0 
±
 5mV.
BIA110
AC 230V
+
-
VR: 0
Input: AUX
Output:
Speaker
Terminal
Electric
Voltmeter
UNIT
Figure 24-5 ADJUSTMENT POINT
BIA110
LFA04 
LFA05 
LFA03 
QA100 
VRA100
ICA110
ICA100
LFA02
LFA01
VRA101
ICA111
ICA112
ICA104
QA101 
LFA06
BIA111
BIA106
BIA112
ICA101
ICA102
ICA103
1 BIT AMP. PWB
OUTPUT OFFSET
L-CH
OUTPUT OFFSET
R-CH
SO301A
ANTENNA
TERMINAL
C393
FE301 
IC302 
CF302 
IC303 
CF352 
BI302 
VR351
T351
T302
T306
TUNER PWB
AM BAND
COVERAGE
AM IF
FM MUTE
LEVEL
TP301
TP302
AM
GND
FM
AM
TRACKING fL
C368
– 25 –
SD-CX1H
MD SECTION
Enter the test mode, adjust or set as shown in the following table according to the repair operations.
Extension Cable
Type
Part No.
1
Extension PWB for servicing
RUNTK0532AFZZ
2
Extension Connector (2 Pin)
QCNWK0129AFZZ
3
Extension Flat Cable (6 Pin)
QCNWK0130AFZZ
4
Extension Flat Cable (5 Pin)
QCNWK0109AFZZ
5
Extension Flat Cable (28 Pin)
QCNWK0108AFZZ
CN1401
CN1402
CN1101
CN1300
From Magnetic Head
2Pin connector
From Optical
Pickup Unit
Extension PWB for service
(RUNTK0532AFZZ)
Fit the extension PWB for service to the mechanism
From mechanism
switch PWB
2Pin extension connector
QCNWK0129AFZZ
28Pin extension flat cable
QCNWK0108AFZZ
6Pin extension flat cable: QCNWK0130AFZZ
5Pin extension flat cable: QCNWK0109AFZZ
MD MAIN PWB
28Pin 
flexible
PWB
5Pin flat cable
From loading
motor PWB
6Pin flat cable
1
1
1
1
2
5
6
28
Figure 25 EXTENSION CABLE
CD SECTION
Since this CD system has the built-in automatic adjustment function, readjustment is not necessary when replacing the pickup.
Therefore, any combinations of PWB and pickup can be made.
Since automatic adjustment is executed every time the disc is changed, each disc can be played in the most appropriate condition.
PICK replacement 
HEAD replacement 
MECHANISM 
replacement
MAIN PWB
assembly replacement
MD microcomputer
replacement
MD LSI replacement
RF IC replacement
EEPROM IC
replacement 
TEMP
basic
setting
TEMP
Execution item
required
Repair
operations
number        to      and
" – " is an item that you don't have to execute.
The EEPROM writing result is shown at the end of the test mode
Although "SET" was written normally, it was not written in the "YOBI COMPLETE" state.
Peform "AUTO-YOBI" adjustment. After making a normal adjustment, 
write the preliminary adjustment into the EEPROM.
OK_EEPROM: "SET" and "YOBI COMPLETE" were written normally
WR_EEPROM:
NG_EEPROM: "SET" could not be written.
indicate the order of inplementation.
Checking
EEPROM
setting
EEPROM_SET
AUTO-YOBI
adjustment
AUTO-
adjustment
AUTO-FAB
adjustment
AUTO–YOBI AUTO–ADJ AUTO–FAB TEST-CANCEL
Writing the
EEPROM
setting
TEST-CANCEL
Writing the
EEPROM
setting
TEST-PLAY
Operation check
TEST-REC
Check the connection between the MD microcomputer and the EEPROM.
1
1
1
1
1
1
1
2
2
2
1
2
2
3
3
3
2
3
3
4
4
4
3
4
4
5
5
5
4
2
5
5
6
6
6
5
3
6
6
7
7
7
8
9
6
5
8
1
8
9
9
9
4
7
7
8
8
8
SD-CX1H
– 26 –
1. EJECT mode
• TEMP setting (of EEPROM setting)
• CONTROL setting (of EEPROM setting)
• Setting of laser power (record/playback power)
2. AUTO pre-adjustment mode
• Automatic pre-adjustment is performed.
3. AUTO adjustment mode
• Automatic adjustment is performed. (After adjustment the grating adjustment mode is set.)
4. AUTO AFB adjustment mode
• Focus adjustment is performed.
• RESULT sub-mode
• Therefore do not set this mode since it is not necessary for the service.
• RESULT mode (final adjustment)
• MANUAL pre-adjustment mode
• MANUAL adjustment mode
• MANUAL AFB adjustment mode
• ERROR DATA
5. EEPROM setting mode
• Various coefficients of digital servo are changed manually.
6. TEST-PLAY mode
• Continuous playback from the specified address is performed.
• C1 error rate measurement, ADIP error rate measurement.
7. TEST-REC mode
• Continuous recording from the specified address is performed.
8. INNER mode
• The position where the INNER switch is turned on is measured.
2. Test Mode
Test mode setting method
1. While the +10 forward button (+10) and the REC LEVEL/MD Fast Forward button ( 
 ) are pressed down together, press
the POWER button and then MD PLAY button. (State  A  is changed to state  B .)
2. Insert the playback-only disc 1 (high reflection disc) or the recordable disc 2 (low reflection disc). (State is changed to  C .)
Above procedures will set the unit to the test mode.
  A  tsm 22
e
: TEST MODE
 represents version of MD microcomputer.
STOP state
  B  EJECT
  C  AUT AJST
 Entering the specific mode
Whenever the CD PLAY/PAUSE button is pressed, the mode is changed.
If the REC button is pressed instead, the mode will change in the opposite order.
 Cancel of test mode
The mode is written on EEPROM by pressing the POWER button. If the POWER button is pressed again, the unit returns to
the normal state.
* Before pressing the POWER button, make sure that the AUTO pre-adjustment, AUTO adjustment, and AUTO AFB adjustment
have been completed.
* After the value of EEPROM is changed or the AUTO pre-adjustment, AUTO adjustment, and AUTO AFB adjustment are
performed again, write on EEPEOM by pressing the POWER button. (When the POWER button is pressed, data is written on
EEPROM.)
* When the value of EEPROM has been changed, write the data on EEPROM once. To perform adjustment using the data, set
the unit to the TEST mode again, perform AUTO pre-adjustment, AUTO adjustment, and AUTO AFB adjustment, and then
write the data again on EEPROM.
• Test Mode
(When the MD STOP button is pressed in the   C  state, the indication  A  is
restored. To restore   C  again, press the CD PLAY/PAUSE button.)
1. Preparation for adjustment
Test disc
Type
Test disc
Part No.
1
High reflection disc TGYS1 (SONY) [for Playback]
RRCDT0101AFZZ
2
Low reflection disc
MiniDisc for checking the recording operation
  ––––––––––––
(commercially available MD)
3
Head Adjusting transparent
RRCDT0103AFZZ
4
Low reflection disc
Pre-adjustment disc  [TEAC Test MD]
88GMMD-213AS or
88GMMD-318
A U T O   Y O B I
A U T O   A J S T
R S T   Y O B I
A U T   A F B
E E P R O M _ S E T
M A N   A F B
M N U   Y O B I
  M N U   A J S T
E R R   D A T A
(ERRER DATA)
(AUTO prelimirary adjustment) 
(AUTO adjustment)
(Advanced AFB adjustment)
(RESULT Y O B I )
RESULT  
 (MANUAL AFB adjustment) 
(MANUAL advanced 
AFB adjustment) 
(EEPROM setting)
(MANUAL prelimirary adjustment) 
– 27 –
SD-CX1H
1. EJECT mode
Step 1
Test mode EJECT state
[ _ _ E J E C T _ _ _ ]
Step 2
Press the CD STOP button.
Playback power output state
[ p p w _ _ _ _ _ _ _ ]
Step 3
Press the CD STOP button.
Rec power output state
[ r p w _ _ _ _ _ _ _ ]
Step 4
Press the CD STOP button.
Therefore do not set this mode since it is not necessary
[ x p w _ _ _ _ _ _ _ ]
for the service.
Step 5
Press the TUNER (BAND) button. TEMP setting of EEPROM setting
(The TEMP setting reference of the EEPROM.)
Step 6
Press the AUX (DEMO) button.
CONTROL setting of EEPROM setting
(The CONTROL setting reference of the EEPROM.)
Step No.
Setting Method
Remarks
Display
* Normally, the voltage at pin 3 of IC1401 becomes as follows:
Playback power output (ppw): Approx. DC 0.2V
Recording power output (rpw): Approx. DC 1.8V
Confirmation of pickup laser power
It is possible to confirm in the record/playback mode with the aid of laser power meter.  However, since the laser power meter
measurement is characterized with dispersion, obtained data are used only for confirmation.
     Reference data (at room temperature 25
°
C)
     Playback: 0.72
±
0.1 mW
     Record: 5.5
±
0.5 mW
Note:
Never see directly the laser light.  Otherwise your eyes are injured.
2. AUTO pre-adjustment mode (Low reflection disc only)
With the pre-adjustment disc (MMD213A or MMD-318)
Step No.
Setting Method
Display
Step 1
Test mode STOP state
[ t s m 
 e 
 ]
Step 2
Press once the CD PLAY button.
AUTO adjustment menu
[ A U T O _ A J S T _ ]
Step 3
Press the MD REC button.
AUTO pre-adjustment menu
[ _ A U T _ Y O B I _ ]
Step 4
Press  once the MD PLAY button. • During automatic adjustment 
 changes as follows.
 : _ _ _ _ _ _ ]
  HAo
→ 
• 
 
• 
 
• 
 
• 
 
• 
 
• 
 
• 
 
• 
 
 →
TCO
End of adjustment
If adjustment is OK, Step 5.
If adjustment is NG, Step 6.
Step 5
Press the MD STOP button.
STEP 2
[ _ C O M P L E T E _ ]
Step 6
Adjustment value output
[  C a n ' t  _  A D J .  ]
Press the MD STOP button.
STEP 2  AUTO adjustment menu
• 
 : Adjustment name
Remarks
3. AUTO adjustment mode
Step No.
Setting Method
Remarks
Display
Step 1
Test mode STOP state
[ t s m 
 e 
 ]
Step 2
Press once the CD PLAY button.
AUTO adjustment menu
[ A U T O _ A J S T _ ]
Step 3
Press  once the MD PLAY button. • In case of high reflection disc 
 changes as follows.
 : _ _ _ _ _ _ ]
  PEG
HAG
• In case of low reflection disc 
 changes as follows.
  PEG
LAG
End of adjustment
If adjustment is OK, Step 4.
If adjustment is NG, Step 7.
Step 4
For grating adjustment
[ _ C O M P L E T E _ ]
Press the MD PLAY button.
STEP 5
*Note 1
Press the MD STOP button.
STEP 2
Step 5
Continuous playback (pit section)
Confirmation of C1 error
[ s 
 c 
 ]
Continuous playback (groove section)
[ a 
 c 
 ]
Step 6
Press the CD STOP button.
Conformation of ADIP error (Low reflection only)
[ a 
 a 
 ]
Press the MD STOP button.
STEP 2  AUTO adjustment menu
Step 7
Adjustment value output
[  C a n ' t  _  A D J .  ]
Press the MD STOP button.
STEP 2  AUTO adjustment menu
• 
 : Adjustment name,  
 : Measurement value,  
 : Address
* Note 1:
Depending on the disc, "#COMPLETE_" may be displayed, which means that the ON position of the INNER switch cannot be
identified clearly. In this case, check the switch in the INNER mode using the specified disc. However, this is not a problem in AUTO
adjustment.
Page of 25
Display

Click on the first or last page to see other SD-CX1 (serv.man5) service manuals if exist.