Procedure:
 1. Cover the Red, Blue CRT lens, projecting Green only.
 2. Adjust green centering magnet (DY) if the projected
green horizontal/vertical line does not line up with the
screen horizontal/vertical center line.
 3. Cover the Green, Red CRT lens, projecting Blue only.
 4. Repeat step 2. for blue.
 5. Cover the Green, Blue CRT lens, projecting Red only.
 6. Repeat step 2. for red.
 7. Cover the Red, Blue CRT lens, projecting Green only.
 8. Adjust green centering magnets until the center of the
monoscope pattern line up with the screen center line.
 9. Cover the Green, Red CRT lens, projecting Blue only.
 10. Adjust blue centering magnets to position the center of
the blue raster W2 away from the center of the green
raster.
 11. Cover the Green, Blue CRT lens, projecting Red only.
 12. Adjust red centering magnets to position the center of
the red raster W1 away from the center of the green
raster.
7.4. Centering Magnet Adjustment
 1. Receive a monoscope pattern.
 2. Set that Fine convergence data (Service mode1) is clear (no correction).
 3. Set that V-Pos data (Service mode1) is [130].
 4. Set that H-Pos data (Service mode1) is [954].
 5. Set that H-Parallel data (Service mode1) is [16].
21
TX-51P950M / TX-51P950X / TX-43P950M / TX-43P950X
Preparation:
 1. Receive an cross hatch pattern with dots (pincushion).
 2. Loosen the centering magnets screws.
 3. Position the longer tab of the four-pole magnet to 90
degrees (uncorrected position).
VM Coil with focus correction magnet
4-pole magnet
 4. Position the long tab of all alignment magnets and of the
dummy ring together in an uncorrected position.
Alignment magnet (or dummy ring)
Procedure:
 1. Receive an cross hatch pattern with dots.
 2. Cover the Red, Blue CRT lens, projecting Green only.
 3. Turn the green electrical focus adjustment VR (on focus
pack) fully counterclockwise and note the position of the
dots at the center of the picture.
 4. Turn the green electrical focus adjustment VR fully
clockwise.
 5. Adjust the four pole magnets until the shape of the dot
at the center of the screen is circular.
 6. Adjust for best green electrical focus with green
electrical focus adjustment VR.
 7. Cover the Green, Red CRT lens, projecting Blue only.
 8. Repeat step 4. ~ step 6. for blue electrical focus.
 9. Cover the Green, Blue CRT lens, projecting Red only.
 10. Repeat step 4. ~ step 6. for red electrical focus.
 11. Receive an monoscope pattern.
 12. Cover the Red, Blue CRT lens, projecting Green only.
 13. If the center of the monoscope pattern is not inside the
15mm circle, shown in below, adjust the centering
magnets. Repeat the alignment magnet adjustments
and four pole magnet adjustments (step 1. ~ step 6.)
Centering magnet adjustment
 14. Cover the Green, Blue CRT lens, projecting Red only.
 15. Repeat step 13. for the red.
 16. Cover the Green, Red CRT lens, projecting Blue only.
 17. Repeat step 13. for the blue.
 18. Following adjustments, fix the centering magnets of DY,
dummy rings of VM coil, four pole magnets of VM coil
and the alignment magnets of VM coil to prevent them
from moving.
7.5. Alignment magnet Adjustment
22
TX-51P950M / TX-51P950X / TX-43P950M / TX-43P950X
Caution
 1. The following adjustment have to be carried out one
with PAL signal (100i/50p) and with NTSC signal
(60p/120i)
.
 2. Deflection adjustment need to set the Coarse/Fine
Convergence to Zero Correction some time.
 3. Before Deflection Adjustment are attempted, CRT Set
up, Electrical Focus and Optical Lens Focus adjustment
must be completed.
8.1. PAL 100Hz mode (100i)
8.1.1. Preparation
 1. Receive PAL monoscope pattern.
 2. Set scan mode to 100Hz.
 3. Set the Picture Menu to NORMAL.
 4. Set the TV to Service Mode 1.
 5. Set the Data of Service Mode 1 as follow
H-Pos
954
Top-Corner
186
V-Pos
130
Bottom-Corner
187
H-Parallel
16
V-S-Correct
62
IVBL C
52
C-Correct
16
 6. Push [ 0 ] button so that set the Data of Coarse/Fine
Convergence to Zero Correction.
 7. Push [ R-TUNE ] button so that projecting Green only.
8.1.2. H-Pos and H-Amp Adjustment
 1. Adjust Monoscope pattern for center of the screen by H-
Pos control.
 2. Adjust Horizontal amplitude for 2.5 ±0.1 division of a scale
by H-Amp control.
8.1.3. V-Amp, V-Linear and V-Pos
Adjustment
 1. Adjust Vertical amplitude for 2.3 ± 0.1 division of a scale by
V-Amp control.
 2. Confirm Vertical Linear as to the balance of circle, if need
adjust V-Linear control.
 3. Confirm Vertical Center , if it is not correct, adjust
Monoscope pattern for center of the screen by V-Pos
control.
8.1.4. Parabola and Trapezoid
Adjustment
 1. Receive PAL cross hatch pattern.
 2. Adjust the vertical line to straight line by Parabola control.
After adjustment,the Parabola data will descend 10 DAC.
 3. Adjust the vertical line to straight line of both side Vertical
line by Trapezoid control.
8 Deflection Adjustment
23
TX-51P950M / TX-51P950X / TX-43P950M / TX-43P950X
8.2. PAL 100Hz V Comp mode
(100i)
8.2.1. Preparation
 1. Receive PAL monoscope pattern.
 2. Set scan mode to 100Hz.
 3. Set the Picture Menu to NORMAL.
 4. Set the TV to Service Mode 1.
 5. Set the Data of Service Mode 1 as follow
H-Pos
954
Top-Corner
185
Bottom-Corner
195
H-Parallel
16
V-S-Correct
73
IVBL C
26
C-Correct
16
 6. Push [ 0 ] button so that set the Data of Coarse/Fine
Convergence to Zero Correction.
 7. Push [ R-TUNE ] button so that projecting Green only.
8.2.2. H-Pos and H-Amp Adjustment
 1. Adjust Monoscope pattern for center of the screen by H-
Pos control.
 2. Adjust Horizontal amplitude for 2.0 ±0.1 division of a scale
by H-Amp control.
8.2.3. V-Amp, V-Linear and V-Pos
Adjustment
 1. Adjust Vertical amplitude for 2.0 ± 0.1 division of a scale by
V-Amp control.
 2. Confirm Vertical Linear as to the balance of circle, if need
adjust V-Linear control.
 3. Confirm Vertical Center , if it is not correct, adjust
Monoscope pattern for center of the screen by V-Pos
control.
8.2.4. Parabola and Trapezoid
Adjustment
 1. Receive PAL cross hatch pattern.
 2. Adjust the vertical line to straight line by Parabola control.
After adjustment,the Parabola data will descend 5 DAC.
 3. Adjust the vertical line to straight line of both side Vertical
line by Trapezoid control.
24
TX-51P950M / TX-51P950X / TX-43P950M / TX-43P950X
Page of 102