Panasonic TX-40CS620E / TX-40CSR620 / TX-40CSR625 Service Manual ▷ View online
Technical Description
Specification of KEY for DTCP-IP, C2MOD, CI Plus, DIMORA, HDCP2, Netflix, Widevine,
Freetime
General information:
Freetime
General information:
1. eMMc Memory(IC8903) for spare parts has the seed of KEY for each.
2. The final KEY data will be generated by LD6 IC (IC8000) when SELF CHECK was done and are stored in both
LD6 IC (IC8000) and eMMc (IC8903).
All KEYs are not generated for all models.
The necessary KEY are only generated and stored depend on the feature of models.
2. The final KEY data will be generated by LD6 IC (IC8000) when SELF CHECK was done and are stored in both
LD6 IC (IC8000) and eMMc (IC8903).
All KEYs are not generated for all models.
The necessary KEY are only generated and stored depend on the feature of models.
Replacement of ICs:
When LD6 IC (IC8000) is replaced, eMMc (IC8903) should be also replaced with new one the same time.
When eMMc Memory(IC8903) is replaced, LD6 IC (IC8000) is not necessary to be replaced the same time.
After the replacement of IC, SELF CHECK should be done to generate the final KEY data.
How to SELF CHECK: While pressing [VOLUME ( - )] button on the main unit, press the MENU button on the remote
control for more than 3 seconds.
TV will be forced to the factory shipment setting after this SELF CHECK.
When eMMc Memory(IC8903) is replaced, LD6 IC (IC8000) is not necessary to be replaced the same time.
After the replacement of IC, SELF CHECK should be done to generate the final KEY data.
How to SELF CHECK: While pressing [VOLUME ( - )] button on the main unit, press the MENU button on the remote
control for more than 3 seconds.
TV will be forced to the factory shipment setting after this SELF CHECK.
Model and Keys:
Model No.
Keys
DTCP-IP C2MOD CI
PLUS DIMORA
HDCP2
Netflix
Widevine
FREETIME
TX-40CS620E Yes None Yes
Yes
Yes
Yes
None
TX-40CSR620 None None Yes Yes Yes Yes None
TX-40CSR625 None None Yes Yes Yes Yes None
TX-40CSR625 None None Yes Yes Yes Yes None
13
Setting Inspection
Voltage Confirmation
A board
Description
Test point
Voltage
PNL12V
TP4000,TP4001
12V ± 1.2V
SUB5V
TP8773
5.17V ± 0.25V
SUB3.3V
TP8705
3.39V ± 0.15V
HDMI3.3V
TP8710
3.3V ± 0.17V
SUB_AI_3.3V
TP2206
3.3V ± 0.17V
EU_TU_1.8V
TP5704
1.84V ± 0.1V
SUB1.5V
TP8101
1.52V ± 0.08V
SUB1.1V
TP8100
1.21V ± 0.06V
USB-WIFI
TP8620
5.15V ± 0.20V
SUB9V
TP5004
9.0V ± 0.4V
WOL3.3V
TP8712
3.3V ± 0.17V
DMD_1.1V
TP5703
1.12V ± 0.11V
SUB_CI_5V TP8400
5.0V ± 0.5V
USB1
TP8615
5.0V ± 0.25V
USB2
TP8611
5.0V ± 0.25V
P board
Description
Test point
Voltage*
Voltage**
24V
TP7407 and GND
<1V
24 ± 2.4V
16V
TP7410 and GND
<1V
16.0V ± 0.6V
5VS
TP7501 and GND
5.2V ± 0.2V
5.2V ± 0.2V
PFC
TP7201 and GND TP7203***
<340V
390V ± 15V
* Connect AC 230V to JK7101 connector (Main switch is OFF).
** Connect DC 3.3V to TV_SUB_ON P3 connector – pin 9 /TP7416/ or set main switch is ON.
** Connect DC 3.3V to TV_SUB_ON P3 connector – pin 9 /TP7416/ or set main switch is ON.
***
Beware, for testing of PFC use the GND (TP7203) in Hot area of P board – risk of electric shock.
14
Service Mode Function
MPU controls the functions switching for each IICs through IIC bus in this chassis. The following setting and adjustment can
be adjusted by remote control in Service Menu
How to enter into Service Mode
While pressing [VOLUME ( - )] button on the main unit, press the [RED] button on the remote control for 3 times within
2 seconds.
2 seconds.
How to exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
CS Maintenance Menu
OPT
EDID CLK
DRV CHECK
OPT
EDID CLK
DRV CHECK
Key Command
Press the ( / / / ) button to step up/down/right/left through the functions and adjustments
Press
the
OK button to change the adjustment values.
Press
the
RETURN button for return to the main menu.
15
System Information
How to access
1. While pressing [MENU] button on the remote control.
2. To select [Help] and then to select [System Information].(see Fig.12, Fig.13)
2. To select [Help] and then to select [System Information].(see Fig.12, Fig.13)
*
Sample only
How to exit
Press the [RETURN] button on the remote control.
System Information
SW version
SW version
3503-10000-abcde
3503
10000
abcde
10000
abcde
Peaks SW
GenX Main
GenX Sub (optional)
GenX Main
GenX Sub (optional)
Status1
0c 8c01-0003 0002-0000
0c
8c01-0003
0002-0000
8c01-0003
0002-0000
Outer model ID
Inner model ID
Panel inch size
Inner model ID
Panel inch size
Status2 000a-027-000f6a
000a
027
000f6a
027
000f6a
LSI Package
LSI Release
Model data version
LSI Release
Model data version
Status3 00-000000-F000
00
00
00
00
F
00
00
00
F
Number of bad block in NAND Flash (dec)
Peaks reboot counter
System crash counter
Emergency (SOS) counter
Peaks NAND Maker ID
Peaks reboot counter
System crash counter
Emergency (SOS) counter
Peaks NAND Maker ID
Status4 A00000-0000001-00000
A
00000
0000001
00000
00000
0000001
00000
Power-On period (A<=100hrs, B<=200hrs, C>200hrs)
Total Power-On time (dec, max is 65535)
Power-On timer (dec, max is 1048575)
Fixed (always)
Total Power-On time (dec, max is 65535)
Power-On timer (dec, max is 1048575)
Fixed (always)
Status5 00000-10000
15e041ff
0
0
0
0
0
1
0
0
0
0
1
0000
15e041ff
15e041ff
SOS history (latest)
SOS history (last time)
SOS history (last but one)
SOS history (2
SOS history (last time)
SOS history (last but one)
SOS history (2
nd
time after shipping)
SOS history (1
st
time after shipping)
Self-check _0-never selfcheck
1-production selfcheck by “FF” or USCM
2-user selfcheck by pressing “OK”
Fixed (always)
Panel ID
1-production selfcheck by “FF” or USCM
2-user selfcheck by pressing “OK”
Fixed (always)
Panel ID
Status6 01040008-1000009 01040008
1000009
Peaks EEPROM version
STM EEPROM version
STM EEPROM version
Status7 00000-0741
00000
0741
0741
STM ROMCOR version
AJAX_CE version
AJAX_CE version
HDAVI
Control
Control
5
5
VIERA Link version is displayed
Fig.12 Fig.13
16
Click on the first or last page to see other TX-40CS620E / TX-40CSR620 / TX-40CSR625 service manuals if exist.