Panasonic TX-40CS620E / TX-40CSR620 / TX-40CSR625 Service Manual ▷ View online
Option Bytes Description
OPTION1
b1
TEXT Ch Refresh
ON (1) / OFF (0)
b2
ID-1
ON (1) / OFF (0)
b3
Macrovision Auto-judge
ON (1) / OFF (0)
b5 Reserved
-
b6
Enable HDMI force reset
ON (1) / OFF (0)
b7 Reserved
-
OPTION2
b0
Adjust Igain enable
ON (1) / OFF (0)
b1
A2 BG enable (5.5MHz)
ON (1) / OFF (0)
b2
A2 DK1 enable (6.26MHz)
ON (1) / OFF (0)
b3
A2 DK3 enable (5.742MHz)
ON (1) / OFF (0)
b4
NICAM scan
ON (1) / OFF (0)
b5
NICAM BG enable (5.5MHz)
ON (1) / OFF (0)
b6
NICAM I enable (6.0MHz)
ON (1) / OFF (0)
b7
NICAM DK enable (6.5MHz)
ON (1) / OFF (0)
OPTION3
b0
NICAM priority
ON (1) / OFF (0)
b1 Reserved
-
b2 Reserved
-
b3
A2 DK2 enable
ON (1) / OFF (0)
b4
Inhibition of countermeasure for SIF signal drop
ON (1) / OFF (0)
b5
Get onid from physical CH (CHINA)
ON (1) / OFF (0)
b6
SSU search enable for HOTEL model
ON (1) / OFF (0)
b7
SASO mute (ASIA)
ON (1) / OFF (0)
OPTION4
b0
Countermeasure for Taiwan NTSC noise sound
ON (1) / OFF (0)
b2
3DYC color motion detect
ON (1) / OFF (0)
b3
RF Clamp Current minimum (TAIWAN)
ON (1) / OFF (0)
b4 Reserved
-
b5 Reserved
-
b6 Reserved
-
b7
Enable workaround for Polsat CAM problem (POLAND)
ON (1) / OFF (0)
OPTION16
b0
PIP (derivate models)
ON (1) / OFF (0)
b1
“Bass Boost” sound menu enable (derivate models)
ON (1) / OFF (0)
b2
“Digital Remaster” sound menu enable (derivate models)
ON (1) / OFF (0)
b3
“XR-Audio Pro Surround” sound menu enabel (derivate models) ON (1) / OFF (0)
b4
“Ambience” sound menu enable (derivate models)
ON (1) / OFF (0)
b5 Reserved
-
b6 Reserved
-
b7 Reserved
-
21
Self Check
How to access
Self-check indication only:
While pressing [VOLUME ( - )] button on the main unit, press [BLUE] button on the remote control.
Self-check indication and forced to factory shipment setting:
While pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote control for more than 3 seconds.
While pressing [VOLUME ( - )] button on the main unit, press [BLUE] button on the remote control.
Self-check indication and forced to factory shipment setting:
While pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote control for more than 3 seconds.
How to exit
Switch off the power with the [POWER] button on the main unit.
Model ID
TX-40CS620 TX-40CSR620
TX-40CSR625
0C
0300018D
00000200
0300018D
00000200
0C
0300018E
00000200
0300018E
00000200
0C
0300018E
00000200
0300018E
00000200
*
Only for TX-40CS620E
Display Ref.
No.
Description
P.C.B.
H14TUN TU6705
TUNER A/DVB-T/T2/C
A-Board
H90STBY IC8000
IC
Peaks-LD6
A-Board
H17LAN IC8903
MAC
A-Board
H00FE IC6800
DVB-T2/T/C
Demodulator A-Board
H96ID IC8903
CI+,*DTCP-IP
A-Board
H97ID2
IC8903
Dimora, HDCP2, Netflix, Widevine
A-Board
H42WIFI
IC8000
IC8601
IC8601
N5HBZ0000114
IC Peaks-LD6
USB HUB
Wifi Dongle
A-Board
Wifi Dongle
H92MEM1 IC8901
EEPROM
STM
A-Board
H91MEM2 IC8903
eMMc
Memory
A-Board
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
TX-40CS620E
TX-40CSR620
TX-40CSR625
TX-40CSR620
TX-40CSR625
40FHD
Self Check Complete
H14TUN
O.K.
H90STBY O.K.
H17LAN O.K.
H00FE O.K.
H96ID O.K.
H97ID2 O.K.
H42WIFI O.K.
H92MEM1 O.K.
H91MEM2 O.K.
H17LAN O.K.
H00FE O.K.
H96ID O.K.
H97ID2 O.K.
H42WIFI O.K.
H92MEM1 O.K.
H91MEM2 O.K.
PEAKS-SOFT *.***
PEAKS-EEP **.**.****
LSI-PACKAGE *.***
LSI-RELEASE *.**
PEAKS-EEP **.**.****
LSI-PACKAGE *.***
LSI-RELEASE *.**
STBY-SOFT *.**.**
STBY-EEP *.**.****
STBY-EEP *.**.****
MODEL ID **
********
********
22
4 sec
Once
Power LED blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking
times
Blinking timing
Contents
Check point
1
BL_SOS
SUB3.3V_SENSE
P BOARD,PANEL
A BOARD, P BOARD
3
IROM SOS
A BOARD
P BOARD
P BOARD
7
SUB3.3V_SENSE_SOS
A BOARD
9
SOUND_SOS
A BOARD
SPEAKERS
12
BE_SOS
A BOARD
13
EMERGENCY
A BOARD
LCD Panel Test Mode
Purpose:
To find the possible failure point where in LCD Panel or Printed Circuit Board when the abnormal picture is displayed.
How to Enter:
While pressing [VOLUME ( - )] button of the main unit, press [YELLOW] button of the remote control three times.
How to Exit:
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
How to confirm:
If the abnormal picture is displayed, go into LCD Panel test mode to display the several test patterns.
And then, judge by the following method.
Still abnormal picture is displayed: The cause must be in LCD Panel.
Normal picture is displayed: The cause must be in A board.
And then, judge by the following method.
Still abnormal picture is displayed: The cause must be in LCD Panel.
Normal picture is displayed: The cause must be in A board.
Remarks:
The test pattern is created by the circuit in LCD Panel.
In LCD Panel test mode, this test pattern is displayed unaffected by signal processing for RF or input signal.
If the normal picture is displayed, LCD Panel must be okay and the cause of failure must be in A board.
In LCD Panel test mode, this test pattern is displayed unaffected by signal processing for RF or input signal.
If the normal picture is displayed, LCD Panel must be okay and the cause of failure must be in A board.
No Light
Light
23
CI SLOT
JK8400A
HDMI3
JK4701A
JK8605
A-BOARD
AV scart
JK301
1
HDMI1
JK4702A
TU6705
A12
SP
A10
K-BOARD
K10
A02A
LCD PANEL
P-BOARD
MAIN IN
HP
JK8603A
P3
ETHERNET
JK31
11A
JK3001B
YUV
, V IN
AUDIO IN
RCA
USB1
JK8602
HDMI2
JK4703A
Wiring Diagram
JK7101
JK8601
D3101
DIGIT
AL
AUDIO
OUT
A16
WIFI
USB2
CN0100
SER
VICE
LD1
KEY
CONTROL
TUNER
24
Click on the first or last page to see other TX-40CS620E / TX-40CSR620 / TX-40CSR625 service manuals if exist.