Panasonic KX-TG8095RUJ / KX-TG8095RUS / KX-TG8095RUT / KX-TGA807RUJ / KX-TGA807RUS / KX-TGA807RUT / KX-TGA809RUS / KX-TGA809RUT Service Manual ▷ View online
17
KX-TG8095RUJ/RUS/RUT/KX-TGA807RUJ/RUS/RUT/KX-TGA809RUS/RUT
7.6.
For Service Hint
Cross Reference:
Battery Charge (P.13)
18
KX-TG8095RUJ/RUS/RUT/KX-TGA807RUJ/RUS/RUT/KX-TGA809RUS/RUT
8 Service Mode
8.1.
Engineering Mode
8.1.1.
Base Unit
19
KX-TG8095RUJ/RUS/RUT/KX-TGA807RUJ/RUS/RUT/KX-TGA809RUS/RUT
Frequently Used Items (Base Unit)
ex.)
Note:
(*1) Refer to Registering a Handset to a Base Unit (P.16). If a Handset is already registered to a Base Unit, you do not have to
register it again.
(*2) When you enter the address or New Data, please refer to the table on the next page.
(*3) When copying the last digit, press [#] to left-shift the whole address string by 1 digit and duplicate the last digit to the right.
To change the copied hex. digit (A-F) to other hex. digit, press [ ] several times until desired hex. digit appears. In this case, the
table on the next page is not applicable.
ex.) When entering “0 x 00EC”, press the keys in the following order.
1. Press [ ] x 5.
2. Press [#].
3. Press [ ] x 4.
(*4) Refer to step 6 in the “Base Unit” section (P.18) in Engineering Mode.
(*5) Refer to How to Clear User Setting (P.23).
register it again.
(*2) When you enter the address or New Data, please refer to the table on the next page.
(*3) When copying the last digit, press [#] to left-shift the whole address string by 1 digit and duplicate the last digit to the right.
To change the copied hex. digit (A-F) to other hex. digit, press [ ] several times until desired hex. digit appears. In this case, the
table on the next page is not applicable.
ex.) When entering “0 x 00EC”, press the keys in the following order.
1. Press [ ] x 5.
2. Press [#].
3. Press [ ] x 4.
(*4) Refer to step 6 in the “Base Unit” section (P.18) in Engineering Mode.
(*5) Refer to How to Clear User Setting (P.23).
Items
Address
Default Data
Remarks
C-ID (FSK) sensitivity
0x0135
0x35
When reducing "35" (hex) from default value,
sensitivity increases.
sensitivity increases.
C-ID (DTMF) sensitivity
0x061D
0x02
When increasing "02" (hex) from default value,
sensitivity increases.
sensitivity increases.
Frequency for BBIC: Ref_CL
0x0132
depends on each unit Use these items in a READ-ONLY mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
cause serious damage to the computer system.
ID of Base Unit: RFPI (*4)
0x011F to 0x0123
depends on each unit.
ID of restored H/S on
Base Unit: IPEI
H/S #1
#2
#3
#4
#5
Base Unit: IPEI
H/S #1
#2
#3
#4
#5
0x0000 to 0x0004
0x0028 to 0x002C
0x0050 to 0x0054
0x0078 to 0x007C
0x00A0 to 0x00A4
0x00A0 to 0x00A4
depends on each unit. The number of H/S depends on the model
number.
Bell length
0x0292
6 sec: 0x3C
This is time until bell stops ringing.
(Unit: 100ms)
(Unit: 100ms)
Reference Voltage level: RVREF
0x0130
depends on each unit.
-
BBIC Version check (*4)
-
EEPROM Version check
0x0187
depends on each unit.
-
All parameters reset; user setting
→ factory default, User OGM, Caller ID, Registration ID → clear (*5)
20
KX-TG8095RUJ/RUS/RUT/KX-TGA807RUJ/RUS/RUT/KX-TGA809RUS/RUT
Desired Number (hex.)
Input Keys
Desired Number (hex.)
Input Keys
0
0
A
[ ] x 1
1
1
B
[ ] x 2
.
.
C
[ ] x 3
.
.
D
[ ] x 4
.
.
E
[ ] x 5
9
9
F
[ ] x 6
Click on the first or last page to see other KX-TG8095RUJ / KX-TG8095RUS / KX-TG8095RUT / KX-TGA807RUJ / KX-TGA807RUS / KX-TGA807RUT / KX-TGA809RUS / KX-TGA809RUT service manuals if exist.