INF-15
SECTION 1 SERVICE INFORMATION
<VMZ60/VMZ50/VMZ40/VMW60/VMW50>
24. KOREA S.GOLF 
  • Setup the improvement of image quality and electrostatic compatibility.(Initial value:OFF)
  - OFF: Do not improve image quality and electrostatic compatibility.
  - ON: Improve the image quality and electrostatic compatibility.
25. KEYSTONE FILTER
  • Improve the sharpness of image during tilt projection.(Initial value: SHARP3)
    Soft3 - Soft2 - Soft1 :Strength of keystone filter is weaken progressively.(Soft3:Minimum strength of keystone filter)
    Default:Moderate strength of keystone filter
    SHARP1-SHARP2-SHARP3:strength of keystone filter is increase progressively.(SHARP3:Maximum strength of  
                                              keystone filter)
    * It can be set only if KOREA S.GOLF is set to ON.
26. HDMI SIG CHG INTR
  • Setup the error times of  allowed signal recognition.
  - If it is less than setting times, it will can not recognize signal again.
  - If it has reached the setting times, it will recognize signal again.
  * It can be set to 0~63 only if KOREA S.GOLF is set to ON.
27. STANDARD MODE IMPROVEMENT
  • Improve the color of standard mode
  When picture mode=standard mode:
  - ON: Use the gamma table in white board mode 
       (※ The setting value for other setting are retained as in the standard mode. Ex: contrast setting etc.).
  - OFF:Use the gamma table in standard mode(Default).
*1 :Please refer to the "SECTION 3<Adjustment>" for detail information of items 10,11,12,14,15,16,19.
INF-16
SECTION 1 SERVICE INFORMATION
<VMZ60/VMZ50/VMZ40/VMW60/VMW50>
4. Notes on service
4.1. Before service operation
4.1.1. Light source
1. LD(Laser) unit that is mounted on the inside of the light source unit is classified in Class 4 of the safety standards.
 
• Laser light is very danger, can damage the human eye and skin.
 
• Please do not perform energization in the state where the lighting block was disassembled.
2. Depending on the operating environment temperature, the luminance of the light source will decrease.
  The higher the temperature becomes, the more the luminance of the light source decreases.
3. The luminance of the light source will decrease by duration of usage.
 
LIGHT POWER
Estimated runtime
NORMAL or QUIET
Approx. 20 000 hours
*1
ECO
Approx. 24 000 hours
*1
  *1: The foregoing time is a rough estimate when the projector is used without changing the settings of [LIGHT POWER],  
       and will vary depending on individual differences and usage conditions.
4. Static electricity or electrical surges will reduce and degrade the reliability of LD unit.
  •  When working with the LD unit take countermeasures to avoid the generation of static electricity, Use or wear appropriate 
work clothes, gloves, shoes, grounded wrist straps and other tools to avoid static electricity.
4.1.2. LCD panel
1.  The display unit of this projector comprises three LCD panels. Although an LCD panel is a product of high-precision tech-
nology, some of the pixels on the image may be missing or constantly lit. Please note that this is not a failure.
2.  Displaying a still image for a longer time may result in an after-image on the LCD panels. If this happens, display the all 
white screen in the test pattern for an hour or more.
4.1.3. Optical parts
The replacement cycle for the optical parts such as the LCD panel or polarization plate may become shorter even
if it is used for less than one year when the ambient temperature is high or in an environment with large amount of
dust or cigarette smoke. For details, consult your dealer.
4.1.4. Air filter unit
1.  Make sure that the air filter unit is properly attached before using the projector. If it is not  properly 
attached, the projector will suck in dirt and dust causing a malfunction.
2. Air filter replacement is recommended after cleaning the unit two times.
  The dust-proof properties may be reduced after each cleaning.
3.  The replacing cycle of air filter unit varies depending on the used environment.
 
Replacement air filter unit
ET-RFV500
INF-17
SECTION 1 SERVICE INFORMATION
<VMZ60/VMZ50/VMZ40/VMW60/VMW50>
4.2. Service
4.2.1. Supporting Methods
The basic service policy is shown below.
Repair contents
Applied parts
Block replacement 
P.C.Board replacement
 
- Lighting case, LD case (* Specified components are replaced)
 
- Optical Block+Lens  mount unit(Only for VMW60/VMW50)
 
- Optical block+Projection lens+lens mount unit(Only for VMZ60/VMZ60B/VMZ50/VMZ40)
 
- K-PCB,P1-PCB,P2-PCB, D-PCB (Specified components are replaced)
 
- LD unit
Replaced by discrete components
Other electrical parts and mechanism parts
4.2.2. Jig and Tool
1. Torx driver T10 [2.72 mm]
  • Part No. : TZSH07035
2. Hex ball-pointed driver or hex wrench (2.0mm/2.5mm) 
  • Commercially available
3. Laser safety glass
  • Part No. : 
DPVF2716ZA/X1
 (or comparable product)
  • Type : Full absorption, Adaptation laser : Ar, Wavelength : 448 - 462nm
  ( Please wear glasses for safety when checking or adjusting  
with the top cover removed.)
4. Heat dissipation grease
  • Part No. : ZG1-G-787 (Internal content 0.4L)
     or Shin-Etsu Silicone [ G-787 ] grade
5. Color luminance meter
  Model: CL-200A (manufactured by KONICA MINOLTA)
4.2.3. Repair
1. Energization check and adjustment, after assembling the lighting block completely.
 
• Before turning on the power, please make sure that the lighting block is completely assembled.
•   The service engineer who works on this model and also other people who are in the same room 
   need to wear the laser safety glasses for avoiding the laser irradiation just in case.
2. Do not disconnect the AC cord or turn off the AC breaker during the fans are operating.
  • Turn off the power after the POWER indicator <ON (G)/STANDBY (R)> lights red.
3. Before repair, make sure to turn off the main power and unplug the power cord from the power outlet.
  *  When replacing the print board, the internal electrical parts can be broken by the static electricity of clothes or human 
body. Be careful of static electricity and wear the anti-static electricity gloves.
4. After repairing, please check the gradation (10step or the gray scale) test pattern or moving image.
   Also, please check that it is normal on a self check screen.
5. Do handling and safekeeping carefully because the user setup information remains in the projector.
(VESSEL   T10H  or equivalant)
INF-18
SECTION 1 SERVICE INFORMATION
<VMZ60/VMZ50/VMZ40/VMW60/VMW50>
4.2.4. Replacement of A-PCB
1.  When the replacement of A-PCB (assembly) is needed, back up the memory information such as adjustment data from the    
old board to PC with the service software. Then transfer this data to the new A-PCB.
   For more information refer to the "SECTION 3<Adjustment>" .
  * Download the service software from Projector service web site.
  * The several types of adjustment data have been stored in the memory ICs listed below.
Ref.
  Stored Data
IC6031 User setting data, Service adjustment data, 
Model No. Serial No.
IC6008 Gamma data, Color shading correction data
2. When A-PCB is replaced, the MAC address of wired LAN or wireless LAN will be changed. 
     Explain it to your customers in advance. 
4.2.5. Optical block type check
There are 2 types of optical block, named R-type and L-type. 
When replacing the optical block, check the printed marker on the flat cable of the G-LCD panel.
GL
GR
• GL => L-type optical block
• GR => R-type optical block
L-type optical block
R-type optical block
G-LCD Panel
If the adjusted data cannot be exported from old 
PCB by using service software, remove ICs from 
the old PCB and mount them on the new PCB.