DOWNLOAD Panasonic PT-RZ120 (serv.man2) Service Manual ↓ Size: 34.64 MB | Pages: 101 in PDF or view online for FREE

Model
PT-RZ120 (serv.man2)
Pages
101
Size
34.64 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 1-CHIP DLP BASED PROJECTOR
File
pt-rz120-sm2.pdf
Date

Panasonic PT-RZ120 (serv.man2) Service Manual ▷ View online

INF-23
SECTION 1 SERVICE INFORMATION
< RZ120 >
4. 3. Security password
4. 3. 1. Control device password
  •To revert to the factory default password (AAAA), perform the following operations while the screen asking for a control
    device password input is displayed.
    1.  Press the [AUTO SETUP] button on the remote control or on the control panel for more than 3 seconds.
    2. Press the [▼] button for more than 3 seconds.
  The password will be initialized.
 
•  The password will also be initialized when performing the menu  [ALL USER DATA] from [PROJECTOR SETUP] 
- [INITIALIZE]. 
4. 3. 2. Initial security password
  •Initial password : Press [p u q t p u q t] button sequentially and press [ENTER] button.
  •If the initial password has been changed, ask user to have it.
4. 2. 3. Repair
  1. Energization check and adjustment, after assembling the lighting block completely.
• Before turning on the power, please make sure that the lighting block is completely assembled.
•   The service engineer who works on this model and also other people who are in the same room need
  to wear the laser safety glasses for avoiding the laser irradiation just in case.
  2. Before repair, make sure to turn off the main power and unplug the power cord from the power outlet.
    *  When replacing the print board, the internal electrical parts can be broken by the static electricity of clothes or human 
body. Be careful of static electricity and wear the anti-static electricity gloves.
  3. After repairing, please check the gradation (10step or the gray scale) test pattern or moving image.
      Also, please check that it is normal on a self check screen.
  4. Do handling and safekeeping carefully because the user setup information remains in the projector.
4. 2. 4. Replacement of printed circuit board
1.  When the replacement of A-PCB (assembly) is needed, back up the memory information such as adjustment data from the 
old board to PC with the service software. Then transfer this data to the new A-PCB.
    For more information refer to the SECTION 3 "Adjustment".
 
•  If you cannot transfer the data by using the software, remove the [IC3711] on the original board and mount it on 
the new board.
2.  When replacing the [A] or [DG] printed circuit board, write the latest version of main firmware again to make consistency 
between Main and FPGA firmware. Each FPGA firmware is updated when updating of Main firmware at the same time.
 
• When [A]-P.C.Board is replaced, the MAC address of wired LAN will be changed. Explain it to the customers 
  in advance.
INF-24
SECTION 1 SERVICE INFORMATION
< RZ120 >
5. Troubleshooting
5. 1. Power/Light source/Temperature indicators
  • The indicators will be lighting or blinking if an error occurs on the projector.
Light source indicator <LIGHT1>
Light source indicator <LIGHT2>
Temperature indicator <TEMP>
Power indicator <ON (G)/STANDBY (R)>
Red
Lit
The power is switched off. (standby mode)
Projection will start when the power on <b> button is pressed.
 
f
The setting of the projector is as follows.
 
g
The [PROJECTOR SETUP] menu → [QUICK STARTUP] is set to [OFF].
 
f
The projector may not operate when the light source indicators <LIGHT1>/<LIGHT2> 
or the temperature indicator <TEMP> are blinking.
Blinking
The power is switched off. (standby mode)
Projection will start when the power on <b> button is pressed.
 
f
The setting of the projector is as follows.
 
g
The [PROJECTOR SETUP] menu → [QUICK STARTUP] is set to [ON].
 
f
The indicator will change to a red light when the specified time has elapsed after the 
projector enters the standby mode if the projector is set as following.
The specified time is the time set in the [PROJECTOR SETUP] menu → [QUICK 
STARTUP] → [VALID PERIOD].
 
g
The [PROJECTOR SETUP] menu → [QUICK STARTUP] is set to [ON].
 
f
The projector may not operate when the light source indicators <LIGHT1>/<LIGHT2> 
or the temperature indicator <TEMP> are blinking.
Green
Lit
Projecting.
Orange
Lit
The projector is preparing to switch off the projector.
The power is switched off after a while. (Changes to the standby mode.)
Note
f
  While the power indicator <ON (G)/STANDBY (R)> lights in orange, the fan is running to cool the projector.
f
  For approximately five seconds after the projector is turned off, the indicator does not light up even if the power is turned on. Turn on the 
power again after the power indicator <ON (G)/STANDBY (R)> lights/blinks in red.
f
  The projector consumes power even in standby mode (power indicator <ON (G)/STANDBY (R)> lights/blinks in red). Refer to Operating  
Instructions “Power consumption” for the power consumption.
f
  When the projector receives the signal from the remote control, the power indicator <ON (G)/STANDBY (R)> will blink in the following 
color according to the status of the projector.
g
  When the projector is in projection mode: Green
g
  When the projector is in standby mode: Orange
However, if the [PROJECTOR SETUP] menu → [STANDBY MODE] is set to [ECO], the indicator will stay lit in red and will not blink if 
the projector is in standby mode.
 
f
The power indicator <ON (G)/STANDBY (R)> will blink slowly in green while the shutter function is in use (shutter: closed), or while the 
function of the [PROJECTOR SETUP] menu → [NO SIGNAL LIGHTS-OUT] is operating and the light source is turned off.
Indicator status
Projector status
Off
The main power is switched off.
Power indicator <ON (G)/STANDBY (R)>
INF-25
SECTION 1 SERVICE INFORMATION
< RZ120 >
Light source indicators <LIGHT1>/<LIGHT2>
Indicator status
Status
Solution
Blinking in red
(1 time)
The light source on one side is turned 
off since the projection lens cannot be 
detected.
f
  Turn off the power and mount the projection lens again. 
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on the power again. 
    The light source indicators <LIGHT1>/<LIGHT2> may not light up or blink.
Blinking in red
(2 times)
Some of the elements of the light 
source are defective and the light 
output has decreased.
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on the power again. 
    The light source indicators <LIGHT1>/<LIGHT2> may not light up or blink.
Blinking in red
(3 times)
The light source does not light up, 
or the light source turns off while the 
projector is in use.
Note
f
  If the light source indicators <LIGHT1>/<LIGHT2> are still lit or blinking after taking the measures, the projector has an abnormality.
f
  The light source indicator corresponding to the light source being lit will light up in green if the projector is in projection mode and there is no 
indication of problem by lighting or blinking in red.
f
  The function to detect the projector lens may or may not exist depending on the country or region where you purchased the product.
Temperature indicator <TEMP>
Indicator status
Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status
Warm-up status
Internal temperature is high 
(warning).
Internal temperature is high 
(standby status).
The cooling fan has 
stopped.
Cause
 
f
Did you turn on the power 
when the temperature 
was low (around 0 °C 
(32 °F))?
 
f
Is the air intake/exhaust port blocked?
 
f
Is the room temperature high?
Solution
 
f
Wait at least five minutes 
in the current status.
 
f
Use the projector 
in an appropriate 
operating environment 
temperature
*1
.
 
f
Remove any objects that are blocking the air intake/
exhaust port.
 
f
Use the projector in an appropriate operating 
environment temperature
*1
.
 
f
Do not use the projector at an altitude of 4 200 m 
(13 780') or higher above sea level.
f
  Check and repair of 
    cooling fan circuit. 
*1  For details of operating environment temperature of the projector, refer to Operating Instructions “Operating environment temperature”.
Note
f
  If the temperature indicator <TEMP> is still lit or blinking after taking the measures, the projector has an abnormality.
INF-26
SECTION 1 SERVICE INFORMATION
< RZ120 >
5. 2. Shutdown system
•   This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector    
has the fan operation error or lightning error. 
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
Not lighting or flashing
Power circuit (P-PCB)
 a
AC input voltage
  Fuse (F9001) : Rated 20A
Blown out of fuse
(with another reason)
Power circuit (P-PCB)
 a
 AC input voltage
  Less than 70V
Lower specified usage AC voltages
STANDBY/ON blinks
3 times in red
F90/F91/F92
A94/A95
FPGA configure error or communication 
error
  F90 : FPGA no response
  F91 : FPGA1 configuration error
  F92 : FPGA2 configuration error
  A94 : FPGA1 communication error
  A95 : FPGA2 communication error
Failure on signal processing part or board 
failure
A98
FM communication error
 a
 Detecting the status error
DG or FM-PCB failure,
Connection failure of the connectors
FH0/FH1(PW1)
FH2/FH3(PW2)
Phosphor wheel rotation speed
  a
 Under 100Hz/1sec or more
 
*  FH1/FH3:Detected by FPGA
       (FH0/FH2:Detected by FM)
Connection failure of the connectors
Phosphor wheel or drive circuit failure
F85/F86
Color wheel rotation speed
 a
 Under 100Hz/1sec or more
 
*  F86:Detected by FPGA
       (F85:Detected by FM)
Connection failure of the connectors
Color wheel or drive circuit failure
STANDBY/ON lights
in red
TEMP lights
H11
Intake air temperature sensor
     a Lower than -20ºC
Intake air temperature sensor connection 
failure or disconnect
H12
Optical module temperature sensor
     a Lower than -20ºC
DMD temperature sensor error
H13
Exhaust air temperature sensor
     a Lower than -20ºC
Exhaust air temperature sensor connec-
tion failure or disconnect
H14 (LD1)
H15 (LD2)
LD1 temperature sensor (H14)
LD2 temperature sensor (H15)
     a Lower than -20ºC
LD1/LD2 temperature sensor connection 
failure or disconnect
TEMP blinks 3 times 
(In Warning: TEMP 
lights)
FE1 - FE9
FF0 - FF2
Each fan sense signal
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds 
Warning at lower than 80%.
Connector disconnected
Fan control circuit failure
Fan rotation error, end of life
If one of the fans stops, 
the projector reduces the 
LD output power.
If more than two fans 
have an error, PJ will be 
shutdown.
FJ0 (PUMP1)
FJ1 (PUMP2)
Each pump sense signal
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds 
Warning at lower than 80%.
Connector disconnection
Pump control circuit failure
Pump rotation error, end of life
When either of the pumps 
fails, same side of light 
source goes off. If both 
of pumps fail, PJ will be 
shutdown. 
Page of 101
Display