Panasonic PT-DZ570U / PT-DZ570E / PT-DW530U / PT-DW530E / PT-DX500U / PT-DX500E (serv.man8) Service Manual ▷ View online
<PT-DZ570U/PT-DW530U/PT-DX500U/PT-DZ570E/PT-DW530E/PT-DX500E>
7. Unscrew the 4 screws and remove the P-P.C.Board.
* AC switch is not attached to the A-P.C.Board for repair.
When change an A-P.C.Board, please change an AC switch at the same time.
When change an A-P.C.Board, please change an AC switch at the same time.
1) Insert an AC switch in a shield case.
2) Fix a new A-P.C.Board with a screw at the prescribed position.
Please be careful so that an AC switch terminal is inserted straight in the board aperture.
Please be careful so that an AC switch terminal is inserted straight in the board aperture.
3) Solder an AC switch terminal.
8. Unscrew the 3 screws and remove the B/Q-P.C.Board.
P-P.C.Board
B/Q-P.C.Board
AC swich
Shield case
P-P.C.Board
Soldered portion
AC swich
DIS-9
1. Adjustment items and procedure ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
ADJ-2
1. 1. Lighting Area Adjustment
1. 2. Lens Tilt Adjustment
1. 3. Color Wheel Index Adjustment
1. 4. EEPROM Data Transfer
1. 5. Model Information Setup
1. 6. Clog Sensor calibration
2. Main/Sub/Network Microprocessor update procedure
・・・・・・・・・・・・・・・・・・・・・・・
ADJ-9
2. 1. Update by LAN Terminal connection
2. 2. Update by serial Terminal Cnnection (Main, Sub Microprocessor only)
CONTENTS
SECTION 3
< Adjustments >
PT-DZ570U / DZ570E
PT-DW530U / DW530E
PT-DX500U / DX500E
PT-DW530U / DW530E
PT-DX500U / DX500E
Model No.
<PT-DZ570U/PT-DW530U/PT-DX500U/PT-DZ570E/PT-DW530E/PT-DX500E>
1. Adjustment item and a procedure
1. 1. Lighting area adjustment
1. 1. 1. Lighting area confirmation
1. After replacing the DMD block, check if any shade is visible in the DMD effective display area.
* Make the projection environment as dark as possible and project an all-white and all-black pattern
(internal test pattern) for this check.
2. When the Lighting area interferes with the effective area, make "Lighting area adjstment".
*
*
1. 1. 2. Lighting area adjustment
1. Project "All White" in internal test pattern with Lamp power"Normal" and Picture mode"Dynamic".
2. Remove 1 screw and remove dust cover sheet.
3. Remove the glue that stationary the adjustment mechanism.
4. Loosen the fixing screw by philips driver.
When the following components in this projector are replaced, adjustments are required. Adjust each item according
to the table below.
to the table below.
Adjustment Items
1.1. Lighting Area Adjustment
1.4. EEPROM data transfer
1.6. Cloggong sensor compensation
1.5. Model Information Setup
1.2. Lens tilt adjustment
Replaced parts
A-P.C.Board
Remarks
DMD Block / Lens
DMD Block / Analysis Block
A-P.C.Board
Save data to a PC before A-P.C.B exchange and
write it into a new A-P.C.B.
write it into a new A-P.C.B.
1.3. Color wheel index adjustment
Color wheel
A-P.C.Board / M2-P.C.Board
When 1.4 Data Transfer is successful, this is not
necessary.
necessary.
Lighting area
Effective
To remove the glue
Adjustment bracket
(Eccentric driver)
(Eccentric driver)
Adjust Screw
(Minus driver)
(Minus driver)
Fixing screw
(Tightening torque:
50~100cN・m)
(Tightening torque:
50~100cN・m)
ADJ - 2
<PT-DZ570U/PT-DW530U/PT-DX500U/PT-DZ570E/PT-DW530E/PT-DX500E>
5. Adjust left and right position of lighting area by rotating the
adjustment screw by minus driver.
When either left or right lighting area appears, rotate the
adjustment screw 1 turn to the opposite direction.
6. Adjust up and down position of lighting area by rotating the
adjustment bracket with eccentric driver.
Stop rotating the eccentric driver at the middle position,
the lighting area appears upper and under.
7. After tightening the fixing screw to secure the glue is
applied to the adjustment mechanism in three places.
8. Tighten the fixing screw and re-install the dust cover sheet.
1. 2. Lens Tilt Adjustment
1. 2. 1. Preparation
< Projector setting befor optical adjustment >
* Fix the shift position to the center and set the zoom
ring to wide end.
* Set the distance from the top of the lens to the
screen "1.23m".
* Set the light axis of the lens to be the same hight
of center of the screen.
* Set the light axis to perpendicular to the screen.
1. 2. 2. Focus Confirmation
Note: It is necessary for the light axis to be perpendicular to the screen to make correct confirmation and adjustment.
1. Go into the Serviceman mode and select "Convergence pattern" in internal test pattern.
2. Rotate the focus ring and set the focus balance of ① to ⑤.
①
②
③
④
⑤
1.23m
Stand
<Projection size>
・DZ570:40 inches
・DW530:38 inches
・DX500:41inches
・DZ570:40 inches
・DW530:38 inches
・DX500:41inches
Applying the glue
One place:0.1~0.15g
One place:0.1~0.15g
<Note>
* Manufacture of glue : CEMEDINE CO., LTD.
* Product name : SX720W
* Manufacture of glue : CEMEDINE CO., LTD.
* Product name : SX720W
Lighting area
Effective area
By adjust screw
By adjustment bracket
ADJ - 3