Panasonic PT-DZ13KU / PT-DZ13KE / PT-DZ13KT / PT-DS12KU / PT-DS12KE / PT-DW11KU / PT-DW11KE / PT-DZ10KU / PT-DZ10KE (serv.man2) Service Manual ▷ View online
DIS-7
2. 5. Removal of Engine Block Case (Top)/DMD Block
1. Remove the Intake Duct (Assy) according to the section 2.4. "Removal of Intake Duct (Assy) / ACF(Assy)".
2. Unscrew the 3 screws and remove the Engine Block Case (Top).
3. Unscrew the 4 screws and remove the DMD Block.
* Attention when assemble the Engine Case (Top).
Please be careful so that shield rubber of the lens mount department side fits into the installation ditch properly.
DMD Block
XYN3+F12FJK
* Depending on the position of the focus,
there is the case that is hard to come off.
In that case, please remove the
RL-P.C.board (two screws).
In that case, please remove the
RL-P.C.board (two screws).
XYN3+F8FJ
Engine Block Case (Top)
RL-P.C.Board
* Please do straight drawing and inserting of
the flexible cable.
A locking mechanism becomes weak when
make drawing and inserting diagonally.
A locking mechanism becomes weak when
make drawing and inserting diagonally.
Shield Rubber
Engine Case (Bottom)
Engine Case (Top)
Installation ditch
DIS-8
2. 6. Removal of Analysis Block/Synthesis Block/Synthetic Mirror
1. Remove the Lamp Unit according to the section 2.2. "Removal of Lamp Unit".
2. Remove the Engine Block Case (Top) according to the section 2.5. "Removal of Engine Block Case (Top) / DMD Block".
3. Unscrew the 2 screws and remove the RL-Board bracket.
4. Unscrew the 2 screws (for each 1) and remove the Lamp Cable Socket (two places).
5. 1) Unscrew the 1 screws and remove the Bimetal cover.
2) Unscrew the 2 screws and remove the Bimetal.
・Unscrew the 4 screws and remove the Analysis Block.
XYN3+F8FJ
RL-P.C.Board
RL-Board bracket
XTW3+8PFJ
XYN3+F8FJ
Lamp Cable Socket
XYN3+F8FJ
XYN3+F8FJK
Bimetal cover
Bimetal
XYN4+J8FJ
XYN4+F10FJK
Analysis Block
DIS-9
6. Unscrew the 4 screws, and divide Analysis Block and Synthetic Block.
・Unscrew the 3 screws and remove the each synthetic Mirror.
2. 7. Removal of Rod (Assy)/Iris Unit (Assy)/Relay Lens
1. Remove the Intake Duct (Assy) and ACF(Assy) according to the section 2.4. "Removal of Intake Duct (Assy) / ACF(Assy)".
2. Remove the RL-Board bracket according to the steps 1 through 3 in the section 2.6. "Removal of Analysis Block /
Synthesis Block / Synthetic Mirror".
3. Unscrew the 2 screws and
remove the Rod cover.
・Unscrew the 3 screws and remove the Rod (Assy).
XYN4+J12FJ
Synthetic Block (lamp case side)
XYN3+F8FN
XYN3+F8FN
Lamp Fan
Lamp Fan
Synthetic Mirror
XYN3+F8FJ
Rod cover
* Please pull straight it up not to injure a
rod integrator.
XYN3+F10FN
Rod (Assy)
* Please be careful so that a fingerprint
and dust do not stick.
DIS-10
4. Unscrew the 4 screws and remove the Analysis Case (Top).
・Unscrew the 2 screws and remove the Iris Unit (Assy).
・Unscrew the 2 hexagon socket head screw and remove
the Relay Lens holder.
・Take off a Lens fixed spring (two places) and remove a Relay Lens.
* Attention when assemble the Analysis Case (Top).
Careful so that the spring of the Relay Lens holder fits into the prescribed position properly.
XYN3+F8FJ
* Analysis case assembling needs the
confirmation of the lighting area afterward.
Please refer to the SECTION3 adjustments.
Please refer to the SECTION3 adjustments.
Analysis Case (Top)
XYN4+J8FJ
(50±5cN・m)
XVE3A10FT
Relay Lens holder
Iris Unit (Assy)
(2.5mm Hex driver)
Push here, and remove a
Lens fixed spring to upside.
Lens fixed spring to upside.
Relay Lens 4
Relay Lens 3
Lens fixed spring
Relay Lens holder
Analysis Case (bottom)
Lens fixed spring
The position where a spring
sticking to a Relay Lens
holder fits into.
holder fits into.
Lens fixed spring
Click on the first or last page to see other PT-DZ13KU / PT-DZ13KE / PT-DZ13KT / PT-DS12KU / PT-DS12KE / PT-DW11KU / PT-DW11KE / PT-DZ10KU / PT-DZ10KE (serv.man2) service manuals if exist.