Panasonic DP-8020E / DP-8020P / DP-8016P (serv.man2) Service Manual ▷ View online
109
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
3.6.
Lubrication Point List
This information is used for routine Preventive Maintenance (PM) calls to ensure the highest degree of
reliability. Inspect the following areas, and lubricate as required. The inspection interval is usually 120K
copies, or more, however the interval may be reduced due to environmental conditions.
reliability. Inspect the following areas, and lubricate as required. The inspection interval is usually 120K
copies, or more, however the interval may be reduced due to environmental conditions.
Mechanical Parts
Ref.
No.
Grease
Lubrication Point
Automatic Duplex Unit
Pinch Timing Roller
712
KS-660
Bias Transfer
Bushing
Bushing
709
110
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
3.7.
Updating the Firmware
The Quickest, and Most Easiest Method of Updating the Firmware is to use the Network Firmware
Tool (FUP) using Ethernet LAN Port, and a Crossover Cable.
The Network FUP Tool version must be 3.XX, or higher, and it can be found on the Panasonic Document
Management System CD-ROM included with the main unit, or on the CD-ROM included with the PCL, or
PS/PCL options.
Refer to the Firmware Update Operation Instructions, Service Notes (8.1.) for additional details.
Tool (FUP) using Ethernet LAN Port, and a Crossover Cable.
The Network FUP Tool version must be 3.XX, or higher, and it can be found on the Panasonic Document
Management System CD-ROM included with the main unit, or on the CD-ROM included with the PCL, or
PS/PCL options.
Refer to the Firmware Update Operation Instructions, Service Notes (8.1.) for additional details.
3.7.1.
Firmware Configuration
A. Hardware Configuration
This machine is controlled by two (2) CPUs which are located on the System Control (SC) PC Board,
and the Scanner Printer Control (SPC) PC Board.
and the Scanner Printer Control (SPC) PC Board.
B. SC PC Board Firmware
The 4 MB Program Memory (F-ROM) is integrated on the SC PCB. An Optional Expansion 8 MB
Program Memory (FRM8 PCB) can be installed into SLOT 1.
The Firmware to be written into the 4 MB onboard, and the 8 MB of SLOT 1 depends upon the
configuration of the Standard, PCL, or PS Options.
Program Memory (FRM8 PCB) can be installed into SLOT 1.
The Firmware to be written into the 4 MB onboard, and the 8 MB of SLOT 1 depends upon the
configuration of the Standard, PCL, or PS Options.
(1) Standard
The Standard Program (1) is only written into the 4 MB onboard, which is assigned as ROM
Code (A).
Code (A).
(2) For PCL Option
The PCL Control Program (2) must be written into the 4 MB onboard, which is assigned as ROM
Code (B). The PCL Control Program (3), and PCL Font data (4) are written into the 8 MB in the
SLOT 1. The Firmware (3), and (4) are assigned as ROM Code (C).
When using 8 MB Flash Memory Card, the 8 MB Program (C) can be written onto one card.
Code (B). The PCL Control Program (3), and PCL Font data (4) are written into the 8 MB in the
SLOT 1. The Firmware (3), and (4) are assigned as ROM Code (C).
When using 8 MB Flash Memory Card, the 8 MB Program (C) can be written onto one card.
SC PC Board
Standard
Configuration
With PCL Option
Configuration
With PS Option
Configuration
On Board
(A)
4 MB
(B)
4 MB
(D)
4 MB
PC
(1)
(2)
(5)
CPU
4 MB
Program
Program
Program
Ethernet Port
F-ROM
PC
USB Port
Slot 1
(C) 8MB
(E) 8MB
(3)
(6)
Program
Program
8 MB
2 MB
(a)
4 MB
(a)
FRM
PCB
(4)
(7)
Flash Memory
Card
Card
Font
4 MB or 8 MB
4 MB
(b)
4 MB
(b)
Slot 2
Not
Used
SPC PC Board
CPU
512 KB
Scanner Control Program
F-ROM
Printer Control Program
Font
111
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
When using 4 MB Flash Memory Card, the 8 MB program (C) must be divided onto 2 cards, one 4
MB card for the PCL Control Program (3), and one 4 MB card for the PCL Font data (4).
MB card for the PCL Control Program (3), and one 4 MB card for the PCL Font data (4).
(3) For PS Option
The PS Control Program must be written into the 4 MB onboard, which is assigned as ROM Code
(D). The PS Control Program (6), and (7) are written into the 8 MB in the SLOT 1.
Both Firmwares (6), and (7) are assigned as ROM Code (E).
When using 4 MB Flash Memory Card, the 8 MB program (E) must be divided onto 2 cards, one 4
MB card for the PS Control Program (6), and one 4 MB card for the PS Control Program (7).
(D). The PS Control Program (6), and (7) are written into the 8 MB in the SLOT 1.
Both Firmwares (6), and (7) are assigned as ROM Code (E).
When using 4 MB Flash Memory Card, the 8 MB program (E) must be divided onto 2 cards, one 4
MB card for the PS Control Program (6), and one 4 MB card for the PS Control Program (7).
C. SPC PC Board Firmware
The 512 KB Program Memory (F-ROM) is integrated on the SPC PCB. The Programs for Scanner
Control, and Printer Control are saved on the Board. The Firmware is transferred as Serial Data from
the SC PCB.
Control, and Printer Control are saved on the Board. The Firmware is transferred as Serial Data from
the SC PCB.
D. Firmware Updating Ports
Three (3) types of Ports are available for updating the firmware.
(1) Ethernet LAN Port (The Quickest, and Most Easiest Method)
The machine's Firmware can be updated from a PC via Local Area Network (LAN). Refer to the
Firmware Update Operation Instructions, Service Notes (8.1.) for additional details.
Firmware Update Operation Instructions, Service Notes (8.1.) for additional details.
(2) USB Port (Alternate)
The machine's Firmware can be updated from a PC via USB Port. The Master Firmware Card can
also be created from a PC using the USB Port. Refer to the Firmware Update Operation
Instructions, Service Notes (8.1.) for additional details.
also be created from a PC using the USB Port. Refer to the Firmware Update Operation
Instructions, Service Notes (8.1.) for additional details.
(3) Flash Memory Card (Alternate)
The machine's Firmware can be updated using the Master Firmware Card. The Master Firmware
Card can be created by copying the Firmware from an existing machine's SC PCB using a 4 MB, or
8 MB Flash Memory Card.
To update the SC, SPC, and PNL PCB, 3 Flash Memory Cards are required for the Standard
configuration, or 5 Flash Memory Cards for the PCL, or PS/PCL configuration.
Card can be created by copying the Firmware from an existing machine's SC PCB using a 4 MB, or
8 MB Flash Memory Card.
To update the SC, SPC, and PNL PCB, 3 Flash Memory Cards are required for the Standard
configuration, or 5 Flash Memory Cards for the PCL, or PS/PCL configuration.
3.7.2.
Updating through a LAN Port (The Quickest, and Most Easiest Method)
The firmware code can be easily updated when the main unit is connected to a LAN.
The Network Firmware Update Tool can also be used by connecting to the machine using a crossover
cable, if the unit is not connected to a LAN.
The Network Firmware Update Tool can also be used by connecting to the machine using a crossover
cable, if the unit is not connected to a LAN.
1) Install the Network Firmware Update Tool to your PC
The option CD-ROM includes the Network Firmware Update Tool, and the Main Unit Firmware Code.
Please refer to the following Operating Instructions to install the Network Firmware Update Tool.
The installation password is "workio".
Operating Instructions:
\xFirmware\Tools\NwFirmup\NwFirmup OI.pdf (Refer to the
Please refer to the following Operating Instructions to install the Network Firmware Update Tool.
The installation password is "workio".
Operating Instructions:
\xFirmware\Tools\NwFirmup\NwFirmup OI.pdf (Refer to the
NW Firmware Update Tool OI
on the CD)
Setup:
\xFirmware\Tools\NwFirmup\Setup\Setup.exe
\xFirmware\Tools\NwFirmup\Setup\Setup.exe
2) Preparing the Firmware Code
Double click the appropriate Destination Shortcut Batch File, and copy the Firmware Code File on the
CD-ROM to the Firmware Data Folder in your PC. Note that the files in the Archive will be extracted
automatically into the designated folder when the Archived file (.exe) is Double-clicked.
CD-ROM to the Firmware Data Folder in your PC. Note that the files in the Archive will be extracted
automatically into the designated folder when the Archived file (.exe) is Double-clicked.
112
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
Example:
From:
Destination Shortcut Batch File: D:(CD-ROM Drive) \ xFirmware \ USA.bat
Firmware Code File:
From:
Destination Shortcut Batch File: D:(CD-ROM Drive) \ xFirmware \ USA.bat
Firmware Code File:
DP-8016_8020_PU_xxxxxx.exe
To:
Firmware Data Folder:
Firmware Data Folder:
C:\ Panasonic \ Panasonic-FUP \ Data
3) Preparing the Main Unit for the Firmware Upgrade
Make sure the unit's Key Operator Password is the same as the tool's password.
Make sure the unit is in an idle state (e.g. not making copies, not printing, etc.).
Make sure the unit is in an idle state (e.g. not making copies, not printing, etc.).
4) Upgrading the Main Unit's Firmware Code
Start the Network Firmware Update Tool, and select the following Firmware Code Folders in the
C:\Panasonic\Panasonic-FUP\Data folder, and then follow the display instructions to upgrade the
Main Unit's Firmware Codes.
C:\Panasonic\Panasonic-FUP\Data folder, and then follow the display instructions to upgrade the
Main Unit's Firmware Codes.
Note:
1. Manual mode must be used, when updating the designated version of the firmware, or changing
the type of the firmware.
Please refer to the Section 2.2, "Setting up the Network Firmware Update Tool, File Selection
Tab" of the Operating Instructions.
Please refer to the Section 2.2, "Setting up the Network Firmware Update Tool, File Selection
Tab" of the Operating Instructions.
2. While updating the firmware code, the display may become garbled, however, it will return to
normal upon completion of the firmware update.
3. If the firmware update fails, and the unit does not boot up, the Network Firmware Update Tool will
not be able to transfer the firmware code. If this occurs, please refer to the next section "Updating
through the USB Port", and use the Local Firmware Update Tool to recover the unit.
through the USB Port", and use the Local Firmware Update Tool to recover the unit.
4. The suffix "_xx" for the Folder Name, or File Name may not exist depending on the destination
location.
3.7.3.
Updating through the USB Port (Alternate Method)
If the device is not connected to the LAN, upgrade the firmware code using the USB Port.
1) Install the Local Firmware Update Tool to your PC
The option CD-ROM includes the Local Firmware Update Tool, and the Main Unit Firmware Code.
Please refer to the following Operating Instructions to install the Local Firmware Update Tool.
Operating Instructions:
\xFirmware\Tools\Firmup\FIRMUP OI.pdf (Refer to the
Please refer to the following Operating Instructions to install the Local Firmware Update Tool.
Operating Instructions:
\xFirmware\Tools\Firmup\FIRMUP OI.pdf (Refer to the
Local Firmware Update Tool OI
on the CD)
Setup:
\xFirmware\Tools\Firmup\Setup\Setup.exe
\xFirmware\Tools\Firmup\Setup\Setup.exe
Parent Firmware File Folder
Sub Firmware File Folder
Transferring Order
\ DP-8016_8020_PU_xxxxxx
\ SC_STD \ DP-LL80AxVxxxxx_xx
1
\ SC_PCL \ DP-LL80BxVxxxxx_xx
1
\ SC_PS \ DP-LL80DxVxxxxx_xx
1
\ SPC \ LL80-SPCAxVxxxxxx
2
When you select the Parent Folder, the following
Firmware Type window appears. Proper Sub File Folders
are selected automatically by selecting the Firmware
Type.
The transferring order is set up automatically.
Firmware Type window appears. Proper Sub File Folders
are selected automatically by selecting the Firmware
Type.
The transferring order is set up automatically.