DOWNLOAD Panasonic DP-8020E / DP-8020P / DP-8016P (serv.man2) Service Manual ↓ Size: 15.37 MB | Pages: 127 in PDF or view online for FREE

Model
DP-8020E DP-8020P DP-8016P (serv.man2)
Pages
127
Size
15.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / DIGITAL IMAGING SYSTEMS
File
dp-8020e-dp-8020p-dp-8016p-sm2.pdf
Date

Panasonic DP-8020E / DP-8020P / DP-8016P (serv.man2) Service Manual ▷ View online

117
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
3.7.8.
Firmware Version
SC
:
SPC
:
DP-LL80
A A Vxxxxx
PU
Destination Code (Copier)
 PU : USA/Canada
 PB : UK
Destination Code (Fax)
 AU : USA/Canada
 AB : UK
Firmware Version (V1xxxx)
Language Code
Firmware Type
 A : Standard
 B, C, D, E : Optional
Model Number
(a)
(AU)
A
c
d
e
j
k
n
Division Soft 
(When it is divided into (a) and (b))
: A-English, C-French & Spanish
: French, German, Italian, Dutch, 
  Portuguese, Spanish, English & Greek
: French, German, Swedish, Norwegian,
  Danish, Finnish, Turkish & English
: French, German, English, Polish, 
  Hungarian, Czech & Russian
: English & Korean
: English & Taiwanese
: English & Chinese
LL80-
A A Vxxxxx
Firmware Version (V1xxxx)
AA: Fixed
SPC
Model Number
SPC
118
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
3.8.
Copy Quality Adjustment Procedure (Order)
No.
Part Item
Adjustment
When the following items are replaced or cleaned, perform adjustments in the correct order.
Work
Optics
Clean
Process
Unit
Clean
Toner
Spill
Tray
Clean
TDC
Adj.
F8-09
OPC
Counter
Reset
F8-14
LSU
Adj.
(Note 4)
Print
F5/F6
(Note 1)
Image
Density
Adj. F6-49
/50/51
(Note 2)
Remark
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Installation
Cleaning
Replace
Main
Optics
Process Unit
Toner Spill Tray
Scanning Lamp
Platen Glass
OPC Drum
Developer
OPC Drum &
 
Developer
Corona Wire
Process Unit
Toner Density
 
Sensor
LSU
SC PC Board
1
1
3
2
1
2
3
4
3
1
1
1
2
2
2
1
1
1
1
1
3
2
2
2
2
1
4
2
5
3
4
2
4
1
4
3
3
3
2
5
3
6
4
5
3
5
2
Replace Developer
Input F5/F6 Parameter
12
3
LSU
PWM
Pattern
Print
F8-18
PWM
Adj.
F6-39
(Note 3)
119
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
Note:
1. Print F5/F6
1) Press “FUNCTION”, “ORIGINAL SIZE”, and “3” keys sequentially to enter the Service Mode.
2) Press the "9" key to enter the F9 Mode (Unit Maintenance).
3) Press the "START" key.
4) Press "3", and "SET" keys.
5) Press "V", or "/\" arrow keys to select "00 F5/F6 PARAMETERS", and press "SET" key.
6) Prints the memory contents of the F5, and F6 modes.
2. Contrast Adjusting
1) Press “FUNCTION”, “ORIGINAL SIZE”, and “3” keys sequentially to enter the Service Mode.
2) Press the "2", and the "START" keys to enter the F2 Mode (Single Copy Test).
3) Set the exposure to the center position.
4) Set the machine to TEXT / PHOTO Mode.
5) Make a copy of Test Chart 53/54 with gray scale (P/N: FQ-SJ1011), and compare the density to the 
chart shown below. If it is within specification, skip to step (14).
a. Gray scale “A” should not be visible.
b. Gray scale “2” should be clearly visible.
6) Press the "STOP" key to exit the F2 Mode (Single Copy Test).
7) Press the “6”, and the "START" keys to enter the F6 Mode (Adjust Parameters).
8) Enter F6-50 Mode (T/P Mode Image Density).
9) Press the "SET" key to highlight the current value.
10) Enter a new value (up to 3-digits).
Note:
The “RESET” key is used to change to a Negative, or Positive (+/-) value.
(+) : Lighter
(-)  : Darker
11) Press the “SET”, and “STOP” keys.
12) Enter F2 Mode (Single Copy Test).
13) Make a copy to confirm the adjustment.
Note:
Repeat Steps (3) to (10) until desired density is attained.
F6-49 : T Mode Image Density (Text)
F6-51 : P Mode Image Density (Photo)
14) Press “FUNCTION”, and “CLEAR” keys simultaneously to exit the Service Mode.
A
1
2
3
(Not visible, or hardly visible)
Not visible
Clearly visible
.
.
.
.
.
.
.
.
.
.
.
.
. .
.
.
.
.
.
.
120
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
3. PWM Adjustment
1) Ensure that Ledger / A3 Size Paper is loaded in one of the Trays, and pull out the remaining trays 
(including the bypass tray) to disable them.
2) Press “FUNCTION”, “ORIGINAL SIZE”, and “3” keys sequentially to enter the Service Mode.
3) Press the "8" key to enter the F8 Mode (Service Adjustment).
4) Press the "START" key.
5) Press the "1", "8", and "SET" keys sequentially to enter the F8-18 "C18 PRT PWM ADJ. PTN.".
6) Press the "START" key to begin the LSU PWM Pattern Printing. 
Sample:
4 gray patches are visible in the illustration, the value of the uppermost patch position is "+2" in 
our example.
7) Press the "STOP" key.
8) Press the "6", and the "START" keys to enter the F6 Mode (Adjust Parameters).
9) Select "39 LSU Unit PWM ADJUST".
10) Press "SET" button, and enter the value of the gray patch, as established in Step (6).
4. LSU Adjustment
Refer to 3.9.
Test Pattern
In our sample, 4 patches 
are visible.
(0)
+2
(-5)
(+5)
Page of 127
Display