3 CAUTION
3.1. NOTE
When you note the serial number, write down all of the 11 digits.
The serial number may be found on the label affixed to the bottom of the unit.
3.2. SAFETY PRECAUTIONS
 1. Before servicing, unplug the power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components for safety.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
3.3. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such as
screw threads, control shafts, handle brackets, etc.
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired and
rechecked before it is returned to the customer.
3.4. BATTERY CAUTION
 1. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s Instructions.
 2. The lithium battery is a critical component (type No.CR23541). Please observe for the proper polarity and the exact location
when replacing it and soldering the replacement lithium battery in.
3.5. CAUTION
The power socket wall outlet should be located near this equipment and be easily accessible.
5
KX-TDA30UA
4 SPECIFICATIONS
4.1. GENERAL DESCRIPTION
Switching
Non Blocking
AC Adapter
AC Input
100 V AC to 240 V AC, 1.5 A, 50 Hz/60 Hz
DC Output
40 V, 1.38 A, (55.2W)
DC Input
    
·
    
DC IN 1:40 V, 1.38 A (55.2 W)
    
·
    
DC IN 2:40 V, 1.38 A (55.2 W)
Maximum Power Failure
Tolerance
300 ms
Memory Backup Duration
7 years
Dialing
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Connectors
Trunk
RJ11 (2 wire) x each Trunk ports
Extension
RJ11 (4 wire) x each extension ports
Paging Output
1 conductor jack
External MOH
(Music on Hold)
Output
1 conductor jack
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Trunk Loop Limit
1600
maximum
Operating
Environment
Temperature
0 °C to 40 °C
Humidity
10% to 90% (non condensing)
Conference Call Trunk
From 10 x 3-party conference call to 4 x 8-party conference call
Music on Hold
1 port (Level Control: -11 dB to +11 dB in 1 dB steps)
Selectable Tone/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
1 port (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (max 115.2 kbps)
USB
1
Extension Connection Cable
SLT
1 pair wire (T, R)
DPT
1-pair wire (D1, D2) or 2-pair wire (T, R, D1, D2)
APT
2-pair wire (T, R, D1, D2)
DSS Console and Add-on Key Module
1-pair wire (D1, D2)
Dimension
275 mm (W) x 376 mm (H) x 117 mm (D)
(10 4/5 in x 14 4/5 in x 4 3/5 in)
Weight (when fully mounted)
Under 3.5 kg (7.72 lb)
4.2. CHARACTERISTICS
Terminal Equipment Loop Limit
    
·
    
PT: KX-T7600 series: 90
; all other DPTs/APTs: 40
    
·
    
SLT: 600
including set
    
·
    
Doorphone: 20
    
·
    
CS: 65
Minimum Leakage Resistance
15000
maximum
Maximum Number of Extension
Instruments per Line
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of a PT and an SLT
3 by Digital eXtra Device Port connection of two DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600
maximum
Hookswitch Flash/Recall Timing Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 5 W per 2 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
Paging Terminal Impedance
600
MOH Terminal Impedance
10000
6
KX-TDA30UA
4.3. SYSTEM CAPACITY
4.3.1. Maximum Trunk and VoIP Line
The Hybrid IP-PBX supports the following number of trunk lines and VoIP lines.
Line Type
Maximum Number
Trunk Line
12
VoIP Line
4
4.3.2. Maximum Terminal Equipment
The following amount of terminal equipment can be supported by the Hybrid IP-PBX. For how to count the total amount of
equipment to be connected, refer to “MEC Card Calculation” (Installation Manual).
Terminal Equipment Type
Without Additional AC Adapter
With Additional AC Adapter
Without MEC
Card
With MEC Card
Without MEC
Card
With MEC Card
SLT
24
24
KX-T7600 series DPT and
KX-T7560/KX-T7565 DPT
Total 24
Total 24
Total 48
KX-T7600 series DPT
24
24
48
KX-T7560/KX-T7565 DPT
24
24
Other types of DPT and APT
Total 4
Total 24
Other types of DPT
4
24
APT
4
4
CS
4
8
PS
28
28
VPS
4 ports (1 VPS)*1
4 ports (1 VPS)*1
SLT, PT, CS, and VPS
Total 28
Total 28
Total 52
Doorphone
4
4
Door Opener
4
4
Add-on Key Module
Total 24
Total 24
Total 48
USB Module
*1 A maximum of 4 ports (8 channels) of a single VPS can be connected to the Hybrid IP-PBX.
7
KX-TDA30UA
5 SYSTEM OVERVIEW
5.1. SYSTEM COMPONENTS
Model
Description
Main Unit
KX-TDA30UA
Main Unit
CO Line Cards
KX-TDA3180XJ
KX-TDA3193XJ
KX-TDA3280XJ
KX-TDA3480XJ
4-Port Analog Trunk Card (LCOT4)
4-Port Caller ID Card (CID4)
2-Port BRI Card (BRI2)
4-Channel VoIP Gateway Card (IP-GW4)
Extension Cards
KX-TDA3171XJ
KX-TDA3172XJ
KX-TDA3173XJ
KX-TDA3174XJ
4-Port Digital Extension Card (DLC4)
8-Port Digital Extension Card (DLC8)
4-Port Single Line Telephone Extension Card (SLC4)
8-Port Single Line Telephone Extension Card (SLC8)
Other Cards
KX-TDA3161XJ
KX-TDA3166XJ
KX-TDA3168XJ
KX-TDA3191XJ
KX-TDA3196XJ
4-Port Doorphone Card (DPH4)
8-Channel Echo Canceller Card (ECHO8)
Extension Caller ID Card (EXT-CID)
2-Channel Message Card (MSG2)
Remote Card (RMT)
Cell Stations (CS)
KX-TDA0141X
2-Channel Cell Station Unit for DECT Portable Station
Proprietary Equipment
KX-A236X
Additional AC Adapter and AC Cord
KX-T30865
Doorphone
Available Proprietary Telephones
The Hybrid IP-PBX supports all of the Panasonic KX-T7000 and KX-TD7000 series:
    
·
    
Digital/Analog proprietary telephones (e.g., KX-T7625, KX-T7630, KX-T7633, KX-T7636)
    
·
    
Portable stations (e.g., KX-TD7690)
    
·
    
DSS consoles (e.g., KX-T7640)
Note:
The Hybrid IP-PBX does not support the following telephones:
    
·
    
KX-T30800 series Proprietary Telephones and DSS consoles
    
·
    
KX-T61600 series Proprietary Telephones and DSS consoles
    
·
    
KX-T123200 series Proprietary Telephones and DSS consoles
8