Panasonic KV-S7097 / KV-S7077 Service Manual ▷ View online
93
Maintenance
Setting
Setting
1. Click “
Maintenance Setting” on the main menu.
2. Click “Change” on “Maintenance Setting” dialog box to
change the parameter value on the “Caution Setting” dialog
box.
box.
3. Click “Roller Cleaning Notification” or “Roller
Replacement Notification” check box to inform the caution
information.
information.
4. Click “Clear Counter” for each counter on “Maintenance
Setting” dialog box and according to the message on the
display, click “OK” to clear each counter.
display, click “OK” to clear each counter.
5. Click “Scanning Glass Cleaning Notification” check box to
inform the scanning glass cleaning timing.
6. Click “OK” to renew the setting.
Clean Roller
Timing:
20000
Timing:
20000
Roller
Cleaning
Notification:
OFF
Cleaning
Notification:
OFF
Replace
Roller
Timing:
300000
Roller
Timing:
300000
Roller
Replacement
Notification:
OFF
Replacement
Notification:
OFF
Scanning
Glass
Cleaning
Notification:
OFF
Glass
Cleaning
Notification:
OFF
Cleaning Mode
1. Close the ADF door.
2. Plug in the power cord and connect the USB cable.
3. Press the power button to turn ON the unit’s power.
4. Start the User Utility.
5. Select Cleaning Mode in User Utility.
6. Press the ADF door release, and open the ADF door.
2. Plug in the power cord and connect the USB cable.
3. Press the power button to turn ON the unit’s power.
4. Start the User Utility.
5. Select Cleaning Mode in User Utility.
6. Press the ADF door release, and open the ADF door.
Raise the Hopper Tray in the and thenpull the Exit Door
Release to open the Exit Door.
Release to open the Exit Door.
7. Enter Cleaning Mode in User Utility.
8. Clean the conveyor rollers.
8. Clean the conveyor rollers.
a.Use the Roller Cleaning Paper to wipe the dirt from the sur-
faces of the conveyor rollers.
b.Press the Start/Stop button on the scanner to rotate the
conveyor rollers a small amount.
c.Repeat these steps until all surfaces of all conveyor rollers
are cleaned.
9. Exit Cleaning Mode after cleaning is completed.
—
Set Default
1. Click “Set Default” on the main menu.
2. Click “Set Default” on the “Set Default” dialog box to set
the default values for “Sleep Mode”, and “Maintenance
Setting”.
3. Click “Close” to return to the main menu.
2. Click “Set Default” on the “Set Default” dialog box to set
the default values for “Sleep Mode”, and “Maintenance
Setting”.
3. Click “Close” to return to the main menu.
—
Item
Operation
Default
Remarks
94
9.3.7.
Test
Item
Operation
Remarks
LED
1. Click “LED” on the test menu.
2. Click “START” on “LED” dialog box to start LED Test
continuously until clicking “STOP”.
3. Click “Close” to return to the test menu.
2. Click “START” on “LED” dialog box to start LED Test
continuously until clicking “STOP”.
3. Click “Close” to return to the test menu.
Each indicator turns on or off
in a constant period.
in a constant period.
Key / Sensor
1. Click “Key / Sensor” on the test menu.
2. Check the key and sensor status on the “Key / Sensor”
dialog box.
2. Check the key and sensor status on the “Key / Sensor”
dialog box.
3. Click “Close” to return to the test menu.
Sensor Sensitive
Level
Level
1. Click “Sensor Sensitive Level” on the main menu.
2. Check each sensor’s sensitive level (Offset, Slice) on the
Sensor Sensitive Level dialog box.
3. Click “Close” to return to the main menu.
2. Check each sensor’s sensitive level (Offset, Slice) on the
Sensor Sensitive Level dialog box.
3. Click “Close” to return to the main menu.
Feed Motor
1. Click “Feed Motor” on the main menu.
2. Click “START” on the “Feed Motor” dialog box to start to
rotate Paper Feed Motor continuously until clicking “STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on the “Feed Motor” dialog box to start to
rotate Paper Feed Motor continuously until clicking “STOP”.
3. Click “Close” to return to the main menu.
Conveyor Motor
1. Click “Conveyor Motor” on the main menu.
2. Click “START” on the “Conveyor Motor” dialog box to start
to rotate the Conveyor Motor continuously until clicking
“STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on the “Conveyor Motor” dialog box to start
to rotate the Conveyor Motor continuously until clicking
“STOP”.
3. Click “Close” to return to the main menu.
Hopper Drive
1. Click “Hopper Drive” on the main menu.
2. Click “START” on the “Hopper Drive” dialog box to start
to execute the Hopper’s Up/Down movement continuously
until clicking “STOP”.
3. Click “Close” to return to the main menu.
2. Click “START” on the “Hopper Drive” dialog box to start
to execute the Hopper’s Up/Down movement continuously
until clicking “STOP”.
3. Click “Close” to return to the main menu.
Good result
Offset : less than 255
Slice : 7
Slice : 7
95
Feed
1. Set documents on the Hopper Tray.
2. Click “Feed” on the main menu.
3. Set “Test Mode” and “Test Condition” depending on each
scanning condition.
Note:
2. Click “Feed” on the main menu.
3. Set “Test Mode” and “Test Condition” depending on each
scanning condition.
Note:
“Imprinter” is available only when the optional
Imprinter is installed.
4. Click “START” on the “Feed” dialog box to start feeding
documents.
Note:
documents.
Note:
When “Flatbed” on the “Test Mode” is selected, check
the CIS Carriage’s sliding from one end to the other
repeatedly is tested.
5. Click “STOP” on the “Feed” dialog box to stop the test.
6. Click “Close” to return to the main menu.
the CIS Carriage’s sliding from one end to the other
repeatedly is tested.
5. Click “STOP” on the “Feed” dialog box to stop the test.
6. Click “Close” to return to the main menu.
7-segment LED
Test
Test
1. Click “7-segment LED” on the test menu.
2. Click “START” on “7-segment LED” dialog box to start
2. Click “START” on “7-segment LED” dialog box to start
7-segment LED Test continuously until clicking “STOP”.
3. Click “Close” to return to the test menu.
Sleep Mode
1. Click “Sleep Mode” on the test menu.
2. Click “START” on the “Sleep Mode” dialog box to enter the
sleep mode.
3. Click “STOP” to return from the sleep mode.
4. Click “Close” to return to the test menu.
2. Click “START” on the “Sleep Mode” dialog box to enter the
sleep mode.
3. Click “STOP” to return from the sleep mode.
4. Click “Close” to return to the test menu.
Item
Operation
Remarks
96
Focus
1. Switch the Reference Plates (F, B) to white.
2. Click “Focus” on the main menu.
3. Set the value for “Gain”. (Value: 140 or less)
4. Select a side (Front or Back).
5. Check “START” of the “Focus” dialog box to start monitor-
2. Click “Focus” on the main menu.
3. Set the value for “Gain”. (Value: 140 or less)
4. Select a side (Front or Back).
5. Check “START” of the “Focus” dialog box to start monitor-
ing the image output level graph.
6. Click “STOP” on the “Focus” dialog box to finish the test.
7. Check “Close” to return to the main menu.
8. Open the Exit Door, and then remove the paper.
7. Check “Close” to return to the main menu.
8. Open the Exit Door, and then remove the paper.
Note:
This operation indicates a focus-level
waveform to check whether there is
any partial depression of the level.
waveform to check whether there is
any partial depression of the level.
If the waveform has any partial
depression, clean the surface of the
ADF Glass (F) or (B).
depression, clean the surface of the
ADF Glass (F) or (B).
When setting "Shading Correction"
by checking the check-box, the image
sensor output-level after shading cor-
rection can be seen.
by checking the check-box, the image
sensor output-level after shading cor-
rection can be seen.
* “Shading correction” check at the time.
Double Feed
1. Click “Double Feed” for “Test” item on the test menu.
2. Set “Send Level” on “Double Feed Sensor” dialog box.
3. Push the ADF Door Release to open the ADF Door.
And hold a piece of clean white paper between Double feed
3. Push the ADF Door Release to open the ADF Door.
And hold a piece of clean white paper between Double feed
sensor (TX) and (R), and then close the ADF Door.
4. Click “START” on the “Double Feed Sensor” dialog box to
start the double feed sensor’s sensitivity test.
5. Check whether the peak level is within the specification.
(See Remarks.)
6. Click “STOP” to finish this test.
7. Push the ADF Door Release to open the ADF Door.
And remove the white paper, and then close the ADF Door.
8. Click “Close” to return to the test menu.
start the double feed sensor’s sensitivity test.
5. Check whether the peak level is within the specification.
(See Remarks.)
6. Click “STOP” to finish this test.
7. Push the ADF Door Release to open the ADF Door.
And remove the white paper, and then close the ADF Door.
8. Click “Close” to return to the test menu.
Memory
1. Click “Memory” on the test menu.
2. Click “START” on the “Memory” dialog box to start the
Memory Read / Write Test.
3. Check the result.
4. Click “Close” to return to the test menu.
2. Click “START” on the “Memory” dialog box to start the
Memory Read / Write Test.
3. Check the result.
4. Click “Close” to return to the test menu.
For details on Error Codes,
refer to Sec. 9.3.2.
refer to Sec. 9.3.2.
Item
Operation
Remarks
Back-graound
Color
Color
Gain
White
140 or less
Good
Result
(Level)
More than 50
*
Send Level
Good result
(Peak Level)
(Peak Level)
Level: 0 to 200 700 or more
Click on the first or last page to see other KV-S7097 / KV-S7077 service manuals if exist.