Panasonic KV-S7075C (serv.man2) Service Manual ▷ View online
73
8.3.17. Conveyor 1
(1) Push the ADF Door Release to open the ADF Door.
(2) Remove the 2 screws (a) and 2 screws (b) with the spacers.
(3) Remove the Conveyor 1 in the direction of the arrow from the
scanner.
scanner.
74
8.3.18. Drive Belts 1, 2, 3
(1) Remove the ADF Cover (B). (See 8.3.14.)
(2) Remove the Drive Belts 1 and 2.
(3) Loosen the 2 screws. Push down the lever until the belt goes
slack, and then tighten the screws to hold the lever in place.
slack, and then tighten the screws to hold the lever in place.
(4) Remove the Drive Belt 3.
Reassembling Note: BELT LAYOUT
a. Reattach the Drive Belt 3 as shown in the following
figure.
b. Loosen the 2 screws. (Loosening the 2 screws will
make the belt tighten properly.)
c. Tighten the 2 screws.
figure.
b. Loosen the 2 screws. (Loosening the 2 screws will
make the belt tighten properly.)
c. Tighten the 2 screws.
75
8.3.19. Drive Rollers 1, 2, 3
(1) Remove the Drive Belts 1, 2, and 3. (See 8.3.18.)
(2) Remove the Conveyor 1. (See 8.3.17.)
(3) Pull out the Drive Rollers 1, 2, and 3 in the direction of the
arrows.
arrows.
76
8.3.20. Double Feed Detector (G)
(1) Remove the Drive Rollers 1, 2, and 3. (See 8.3.19.)
(2) Remove the 2 screws through the holes.
Reassembling Note:
Be careful not to crimp or pinch the wires when
tightening the screws.
tightening the screws.
(3) Disconnect the 1 connector.
(4) Release the stoppers of the detector base to remove the
Double Feed Detector (G).
Double Feed Detector (G).
Click on the first or last page to see other KV-S7075C (serv.man2) service manuals if exist.