33
8.4.
Change of Compressor rota-
tional speed
  [P2]
When you receive service call about Compressor noise, you
can change the Compressor rotational speed tentatively when
checking noise.
HOW TO SET
1. Set in SERVICE MODE.
(Press [FRESH FREEZING] button for 5 seconds.) 
2. Press the buttons as follows.
• At first, {C} and {--} are displayed on the Notice indicator. 
Other signs can be seen refer to “Service Mode” (Sound
Inhibition Mode and Vibration Inhibition Mode).
3. you can change Compressor rotational speed by
{FREDGE} or {FREEZER} button.
HOW TO CANCEL
CAUTION
• When setting to intermittent cooling mode, this function can
not be performed.
• This function can be performed only when Compressor is
running.
If there is cooled below the setting temperature during this
function, Compressor is stopped.(While Compressor has
stopped, {C} and {00} are displayed on the Notice indicator.)
• If Compressor stops, change the temperature control to
lower setting or open FC door.
Then, Compressor starts running.
8.4.1.
Rotational speed range
*1 When the following all of conditions are met, Compressor
rotational speed is changed to R6.
• AT 34°C or above
•  {FRESH FREEZING} and {QUICK ICE MAKING} are operating
• Compartment temperature rises largely.
8.5.
ECO-NAVI LAMP (LED) Test
• ECO-NAVI Lamp can be quickly tested whether the lamp is
turned on.
• Even while setting in ECO-NAVI LAMP DISABLE or ECO-
NAVI MODE DISABLE, the ECO-NAVI Lamp is turned on for
confirmation.
HOW TO SET
1. Set in SERVICE MODE.
(Press [FRESH FREEZING] button for 5 seconds.) 
2. Shield the sensing part of light sensor from the light.
After 5 seconds, ECO-NAVI Lamp is turned on.
After ECO-NAVI Lamp is turned on, even if the lightproof
one is uncovered, ECO-NAVI Lamp has continued to turn
on.
(If the DOOR (PCR) is opened once or SERVICE MODE is
finished, ECO-NAVI Lamp is turned off.)
HOW TO CANCEL
• Open and close the door (PC/IC/FC).
Setting 
level
Vibration 
inhibition mode
Normal
Sound 
inhibition mode
R1
Same as 
on the right.
C30 (1,800)
Same as 
on the left.
R2
C30 (1,800)
R3
C42 (2,520)
R4
C52 (3,120)
R5
C62 (3,720)
R6
C71 (4,260)
-----*1
34
9 Service Mode
• All of Fan motors (CT, FC and WE) are forcibly operated when setting in SERVICE MODE. 
35
9.1.
Self diagnosis function
When abnormality is caused in the refrigerator, the sign is displayed on Notice indicator.
The display sign list is put on the PCB COVER ASSY in the top of cabinet.
Sign
Condition
Check point
Display release
U10 Warning that door is kept open.
*3
Leave the door open more than 1 min-
ute.
(Interior lamps are flashing.)
1.Close compartment door completely
2.Door switch, circuit
3.Door alignment
4.Control PCB
Close the door
Adjust door
Replace parts
H01 FC temperature sensor circuit has 
trouble.
Open or short
1.FC sensor, circuit 
2.Control PCB
Reset display
or
Replace parts
H02 PC temperature sensor circuit has 
trouble.
Open or short
1.PC sensor, circuit 
2.Control PCB
H03 PF temperature sensor circuit has 
trouble.
(on the PCB (PFC))
Open or short
1.PCB (PFC)
2.Control PCB
H05 Defrost sensor circuit has trouble.  Open or short
1.Defrost sensor, circuit
2.Thermal fuse, circuit
3.Control PCB
H07 ATC sensor circuit has trouble.
(on the ECO NAVI PCB)
Open or short
1.ATC sensor, circuit
2.Control PCB
H18 VC temperature sensor circuit has 
trouble.
Open or short
1.VC sensor, circuit 
2.Control PCB
H21 Ice-maker has trouble.
(Stop to protect Ice-maker)
When Ice maker had the trouble of rota-
tion 16 continuous times.
1.Ice-maker
2.Control PCB
H28 Fan motor (CT) for Compressor 
room is opened or locked.
Lock or open
1.Something touches fan blade
2.Fan motor for Compressor room, 
circuit
3.Control PCB
H29 Fan motor (FC) for evaporator is 
opened or locked.
Lock or open
1.Ice has formed on the fan.
2.Fan motor for evaporator, circuit
3.Control PCB
H31 FC Defrost heater circuit has trou-
ble.
Temperature of Defrost sensor does not 
reach cut-off temperature.
1.Defrost sensor, circuit
2.Defrost heater
3.Thermal fuse
4.Control PCB
H35 Refrigerating unit has trouble.
(Gas leakage at high pressure 
side / Poor compression)
Even if Compressor runs, FC sensor 
and Defrost sensor have detected 0°C 
or above continuously for 10 hours.
1.Gas leakage at high pressure side
2.Poor compression
H36
*1
Refrigerating unit has trouble.
(Gas leakage at low pressure 
side)
When the Compressor runs normally 
after {H40} is detected, and when {H40} 
is detected again within 48 hours.
1.Gas leakage at low pressure side
Replace parts
H38
*1
Rotation of Fan motor (FC) has 
trouble.
Signal circuit is trouble. *2
1.Control PCB
2.Fan motor (FC)
H40
*1
IPM & Compressor protection 
control has trouble.
Overcurrent flow into IPM for a long 
time.
1.Control PCB
2.Compressor(Lock)
H41 Undervoltage protection has trou-
ble.
Low voltage add to unit for a long time. 1.Power supply voltage
2.Control PCB
Reset display
or
Replace parts
H43 Fan motor (WE) for Water pan is 
opened or locked.
(on the Water pan)
Lock or open
1.Something touches fan blade.
2.Fan motor for Water pan, circuit
3.Control PCB
H50 Communication error
The signal does not flow IC1 and 
IC201, or the signal does not flow IC1 
and IC701.
1.Wire circuit between Control PCB 
and Operation PCB
2.Control PCB
3.Operation PCB
H51
*1
Control PCB has trouble.
When the power is on, microcomputer 
can not read or write the data.
1.Control PCB
Replace parts
H52
*1
Control PCB has trouble.
(Inverter voltage)
Inverter voltage is too high.(Full voltage 
control) Inverter voltage is too low.(Dou-
ble voltage control) 
1.Control PCB
H64
*1
Light sensor has trouble.
(on the PCB(ECO NAVI))
Light sensor has trouble for 1 week.
1.Light sensor
H65
*1
Storage sensor has trouble.
While turning on LED in PC, Storage 
sensor has trouble.
1.Operation PCB
H79
*1
Continuous overload detection.
PC temperature is high, and it doesn't 
decrease for 1 day.
1.Damper
2.Duct
3.Close compartment door completely
4.Control PCB
36
• The signs are appeared twice separately.
  EXAMPLE:{H01} is displayed the sign {H} on Notice indicator first, next {01} is displayed.
• Check the CHECK POINT in ascending order (1.2.3...).
• In the case of normally recovery during {H**} sign, the sign is disappeared.
• Display reset: press [FRIDGE] button for 3 seconds, and a beep sounds, then Notice indicator {H**} is turned off.
However, {H50} and displaying history do not disappear.
If it still continues the defective condition, the sign will be re-displayed.
 (Most of cases take between several minutes and several hours.)
In the case of faulty sensor circuit, Notice indicator is displayed again after 10 seconds.
• When setting in SERVICE MODE during malfunction signal, the voltage of Fan motor is turning on and off 
every 3 seconds repeatedly.It is easy to confirm the output voltage and identify the cause of abnormality. 
*1... These signs appear when SERVICE MODE is controlled.(Normally customer can not see these signs.)
     When SERVICE MODE is finished, displaying history is deleted except self diagnosis sign which is continued to display 
     on the Notice indicator.
*2... If a signal circuit is disconnected, Fan motor will become a high velocity revolution and a refrigerator will not cause
     the shortage of cooling.
*3... {U10} will disappear when to unplug. However, if the trouble continue, the sign {U10} will appear again.
     When setting in SERVICE MODE, the beep sound and Interior lamps (LED) flashing have stopped for 24 hours. 
     However, {U10} sign is displayed continuously.
9.2.
Special function
The following functions for Compressor operation, temperature setting, and other control can be changed from normal setting to
special setting during SERVICE MODE as needed. 
9.2.1.
Forced Defrosting with Pre-cooling
• After the refrigerator is cooled enough, the Forced defrosting
operation is started.
• Forced defrosting operation will be automatically finished
when FC temperature (Defrost sensor) rises to certain tem-
perature.
HOW TO SET
1. Set in SERVICE MODE.
(Press [FRESH FREEZING] button for 5 seconds.) 
2. Press the buttons as follows.
HOW TO CANCEL
• Turn the power OFF.
9.2.2.
Sound Inhibition Mode  [S0]
Maximum rotational speed is lowered one step to inhibit the fast
rotational sound (noise) when the Compressor is operating with
ambient temperature of 34°C or above.
• Conditional rotational speed is not changed to R6.
• However, this does not apply during FRESH FREEZING and
QUICK ICE MAKING.
• Even when the refrigerator is powered off, this setting has
remained on the refrigerator.
HOW TO SET... {S0} 
{on}
1. Set in SERVICE MODE.
(Press [FRESH FREEZING] button for 5 seconds.) 
2. Press [FRESH FREEZING] button for 1 second. 
3. Press the buttons as follows.
HOW TO CANCEL... {S0}
{oF} 
1. Set in SERVICE MODE.
(Press [FRESH FREEZING] button for 5 seconds.) 
2. Press [FRESH FREEZING] button for 1 second. 
3. Press the buttons as follows.
How to confirm the operation
Following sign is displayed in the Notice indicator after {C}
when the Compressor rotational speed is changed in the
Test mode.
Page of 97