Panasonic NR-F610GT-N8 Service Manual ▷ View online
25
4.15. Fan Motor (WE) Control for
Water Pan
The Fan motor (WE) is controlled to promote the evaporation of
the defrosted water.
the defrosted water.
• Rotational speed changes on 4 degrees according to rota-
tional speed of the Compressor.
• If malfunction signal is detected for a second when Fan
motor turns on, the Fan motor has turned off for 2 minutes
and then it will turn on again.
and then it will turn on again.
• When malfunction signal is detected 10 times in a row, {H43}
is displayed in the Notice indicator (Fan motor (WE) is
abnormal).
When setting in SERVICE MODE during malfunction signal,
the voltage of Fan motor is turning on and off every 3 sec-
onds repeatedly.
abnormal).
When setting in SERVICE MODE during malfunction signal,
the voltage of Fan motor is turning on and off every 3 sec-
onds repeatedly.
• Even after the {H43} is displayed, it will return to normal con-
trol when the malfunction signal is not detected for 5 sec-
onds or above.
onds or above.
AT
Compressor
Fan motor
22°C or below
ON
ON
OFF
OFF *1
23°C or above
ON
ON
OFF
OFF
During SERVICE MODE
ON*2
*1. The Fan motor is operated for 10 minutes after the Compressor
stops.
*2. The Fan motor stops while defrosting.
stops.
*2. The Fan motor stops while defrosting.