DOWNLOAD Panasonic NR-F610GT-N8 Service Manual ↓ Size: 12.44 MB | Pages: 97 in PDF or view online for FREE

Model
NR-F610GT-N8
Pages
97
Size
12.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Home Appliance / REFRIGERATOR
File
nr-f610gt-n8.pdf
Date

Panasonic NR-F610GT-N8 Service Manual ▷ View online

25
4.15. Fan Motor (WE) Control for
Water Pan
The Fan motor (WE) is controlled to promote the evaporation of
the defrosted water.
• Rotational speed changes on 4 degrees according to rota-
tional speed of the Compressor.
• If malfunction signal is detected for a second when Fan
motor turns on, the Fan motor has turned off for 2 minutes
and then it will turn on again.
• When malfunction signal is detected 10 times in a row, {H43}
is displayed in the Notice indicator (Fan motor (WE) is
abnormal).
When setting in SERVICE MODE during malfunction signal,
the voltage of Fan motor is turning on and off every 3 sec-
onds repeatedly.
• Even after the {H43} is displayed, it will return to normal con-
trol when the malfunction signal is not detected for 5 sec-
onds or above.
AT
Compressor
Fan motor
22°C or below
ON
ON
OFF
OFF *1
23°C or above
ON
ON
OFF
OFF
During SERVICE MODE
ON*2
*1. The Fan motor is operated for 10 minutes after the Compressor 
stops.
*2. The Fan motor stops while defrosting.
26
5 Location of Controls and Components
5.1.
Components
27
5.2.
Control panel and Button
28
6 Installation Instructions
6.1.
How to use the WRENCH ADJUSTER BOLT
Page of 97
Display

Click on the first or last page to see other NR-F610GT-N8 service manuals if exist.