DOWNLOAD Panasonic NR-F610GT-N8 Service Manual ↓ Size: 12.44 MB | Pages: 97 in PDF or view online for FREE

Model
NR-F610GT-N8
Pages
97
Size
12.44 MB
Type
PDF
Document
Service Manual
Brand
Device
Home Appliance / REFRIGERATOR
File
nr-f610gt-n8.pdf
Date

Panasonic NR-F610GT-N8 Service Manual ▷ View online

17
4 Technical Descriptions
4.1.
How to operate the Control panel
4.1.1.
Normal time
• Normally, the indicators are off to save energy.
• During the FRESH FREEZING, QUICK ICE MAKING, or
ECO-NAVI operation, the corresponding lamp is on to notify
you that the operation is being performed.
• During the SERVICE MODE,
(To set SERVICE MODE, keep pressing down [FRESH
FREEZING] button for 5 seconds.)
- Press [FRIDGE] button to select a menu in ascending
order.
- Press [FREEZER] button to select a menu in descending
order.
- Press [AUTO ICE OFF] button to perform an operation. 
- Press [FRESH FREEZING] button to finish an operation.
4.1.2.
Initial time (Power ON)
All indicators turn on when the power is on, and then they turn
off after approximately 5 seconds.
4.2.
Temperature Control for each compartment
4.2.1.
FRESH FREEZING & QUICK ICE MAKING Controls 
The following table is described the controls for {FRESH FREEZING} & {QUICK ICE MAKING}.
Input
Output
• Refrigerator compartment
• PCC sensor signal
• ATC sensor signal
• PC Temperature setting signal
• PC Damper opening and closing
(Close when Compressor stops)
• Prime fresh / Chilled select 
room
• PFC sensor signal
• ATC sensor signal
• PF Temperature setting signal
• PF Damper opening and closing
(Close when Compressor stops)
• Vegetable compartment
• VCC sensor signal
• ATC sensor signal
• PC/FC Temperature setting signal
• PC damper
• VC heater on/off
• VC Damper opening and closing
(Forcibly open when PC damper is opened)
• Freezer compartment
• Ice compartment
• Fresh freezing room
• FCC sensor signal
• ATC sensor signal
• FC Temperature setting signal
• Compressor rotational speed
• Fan motor (FC) rotational speed 
Operation/Current setting
FRESH FREEZING
QUICK ICE MAKING
Function
Quickly freeze food
Quickly make ice cubes
Operating time
Approx. 150 minutes
Approx. 6 hours
 (Afterwards, it returns to normal Auto Ice-making.) 
If it is set while defrosting
It starts after defrosting is finished.
{QUICK ICE MAKING} flashes on and off.
It starts after defrosting is finished.
If it is set {FRESH FREEZING} 
during another operation.
-
FRESH FREEZING takes priority.
QUICK ICE MAKING is cancelled.
If it is set {QUICK ICE MAKING} during
another operation.
QUICK ICE MAKING takes priority.
FRESH FREEZING is cancelled.
-
18
4.3.
FRESH FREEZING Control
Compressor and Fan motor (FC)  continuously operate for a
specified time depending on the ambient temperature, regard-
less of the compartment temperature.
HOW TO SET
Press [FRESH FREEZING]
(beep)turn on the lamp
HOW TO CANCEL
Press [FRESH FREEZING]
(beep)turn off the lamp
4.3.1.
Operation time
4.4.
PC Interior Lamp (LED) Control
• When PC doors are opened during operation, the following
Interior lamps (LED) are turned on.
LED : PC both sides, top (total 3 places)
Blue LED : PC left lower side (Storage sensor)
• When PC doors are closed during operation, Interior lamps
(LED) are controlled to determine the change in the volume
of storage in Refrigerator compartment.
For details, refer to “ECO-NAVI Control”.
4.4.1.
Interior lamp flashing control
If PC, IC or FC door has opened for 1 minute, Interior lamps
(LED) are flashed.
• After setting in SERVICE MODE, Door alarm and Interior
lamps (LED) flashing have stopped for 24 hours.
However, {U10} indicates on Notice indicator during door
opening.
• When making the Door alarm operate after SERVICE MODE
is finished, first unplug and wait for 7minutes, then plug in.
4.4.2.
Auto Interior lamp Off
If PC door has opened for 1 hour, Interior lamps(LED) automat-
ically turn off. Once closing PC door, this function is reset.
4.4.3.
PC Blue LED Off
Even when opening PC doors, Blue LED (Storage sensor) can
not be turned on.
For details, refer to “Service Mode”.
4.5.
Door Alarm
CONDITION
• Door switches are related to PC door, IC door and FC door.
Each door is opened more than 1 minute.
OPERATION
• Door alarm sounds and {U10} is displayed on Notice indica-
tor.
If the door is closed, Door alarm is stopped and {U10} is dis-
appeared.
• After setting in SERVICE MODE, Door alarm and Interior
lamps (LED) flashing have stopped for 24 hours.
However, {U10} indicates on Notice indicator during door
opening.
• When making the Door alarm and Interior lamps (LED) oper-
ate after SERVICE MODE is finished, first unplug and wait
for 7minutes, then plug in. 
4.6.
Demonstration Mode
Until the first defrosting start, Demonstration Mode can be set
for display in the showroom.
If Demonstration Mode is operating, only Interior lamps(LED),
Door alarm, and Door panel LED can be operated. And other
functions are off. 
HOW TO SET
HOW TO CANCEL
CAUTION
• It is not possible to cancel by the power-off while the Demon-
stration Mode is operating. 
• This mode becomes invalid after the first defrosting.
Ambient temperature Operation time
COMP ON
COMP OFF
19°C or above
150 minutes
All time
0 min
11°C to 18°C
150 minutes
60 min
10 min
10°C or below
150 minutes
40 min
10 min
Door opening
Interior lamp (LED)
After 1 minute
Flashes once
After 3 minutes
Flashes twice
After 5 minutes
Flashes three times
After more than 
5 minutes
Flashes three times every 2 minutes
Door opening
Buzzer sounds
After 1 minute
Pee-Pee
After 3 minutes
Pee-Pee, Pee-Pee
After 5 minutes
Pee-Pee, Pee-Pee, .......................
19
4.7.
ECO-NAVI Control
ECO-NAVI is operated automatically to save energy based on
usage volume of refrigerator (Change in the volume of storage
in the Refrigerator compartment (PC), Door opening and clos-
ing, or Brightness around the refrigerator).
4.7.1.
ECO-NAVI Mode
When the conditions are met, ECO-NAVI Lamp turns on and
ECO-NAVI Mode is started as follows.
• When passing approximately 5 minutes after ECO-NAVI
Lamp turns on, the brightness of lamp is lowered by half.
• It is operated to correct cooling temperature setting 
(plus 1-2°C).
• Defrosting period is extended for 13-24 hours.
(Normal defrosting period : 13 hours)
4.7.1.1.
Preconditions
Following all of conditions are met.
*1. Except for Fine adjustment of temperature setting.
4.7.1.2.
Initiation conditions 
Any one of following conditions are met.
4.7.1.3.
Termination conditions
If one of following conditions is met, it terminates the ECO-
NAVI (energy saving) operation and ECO-NAVI Lamp turns off.
4.7.1.4.
ECO-NAVI Lamp Disable
The ECO-NAVI Lamp can be turned off during ECO-NAVI oper-
ation.
HOW TO SET (Disable)
Above setting can not set up while displaying the Notice indica-
tor.
HOW TO CANCEL (Enable)
Above setting can not set up while displaying the Notice indica-
tor.
4.7.2.
PC stored volume determination 
control
After opening and closing the PC doors, Interior lamps (LED)
turn on in turn and light sensor detects the change in the vol-
ume of storage.
During detection, ECO-NAVI Lamp is flashing slowly depending
on the setting of temperature control.
1. Interior lamps (LED) operation
• The following operation starts in turn after opening and
closing the PC doors.
a. All of LED : OFF (0.9 sec)
b. Top LED : ON (2 sec) → OFF (0.8 sec)
c. Left side LED : ON (2 sec) → OFF (0.8 sec)
d. Right side LED : ON (2 sec) → OFF (0.8 sec)
e. Left lower side Blue LED : ON (2 sec) → OFF
Input
Output
• Temperature control 
setting (condition)
• Door switch
• Light sensor
• PCC sensor1
• Storage sensor
• FCC sensor
• Elapsed time
Indication
• ECO-NAVI Lamp
Temperature 
control 
• Compressor
• Twin Damper
Heater control 
• French crossrail 
heater
• Defrost heater
• VC heater
PC Temperature setting  {2} *1
FC Temperature setting 
{2} *1
FRESH FREEZING
OFF
QUICK ICE MAKING
OFF
Temp (PCC sensor1)
Damper opened, within plus 3°C
Temp (FCC sensor)
Compressor operated, within plus 3°C
Notice indicator
No displayed
When it's bright
 (Light sensor)
Total number of door opening and closing for 3 
hours (PC,FC and IC door) is 1 or less.
When it's dark
 (Light sensor)
Total number of door opening and closing for 5 
minutes (PC,FC and IC door) is 1 or less.
When reaching the 
minor thermal load-
ing period
(The minor thermal loading period : refer to the 
Learning function)
Total number of door opening and closing for 10 minutes (PC,FC and 
IC door) is 3 or more.
Temperature control is set to anything other than {2}.
When starting the operation of {FRESH FREEZING} or {QUICK ICE 
MAKING}.
Following condition has continued for 5 minutes.
Temperature (PCC sensor) > Damper thermostat opened, plus 3°C
Following condition has continued for 5 minutes.
Temperature (FCC sensor) > Compressor operated, plus 3°C
The sign {H} or {U} is displayed on the Notice indicator.
When approaching an hour before the end of minor thermal loading 
period.
(The minor thermal loading period : refer to the Learning function)
The increase in the volume of storage is detected.
(refer to the PC stored volume determination control)
20
2. ECO-NAVI Lamp operation
• All of following conditions are met, ECO-NAVI Lamp is
flashing 3 times and starts normal control.
• While determining the volume of storage in the Refriger-
ator compartment, ECO-NAVI Lamp is operated as fol-
lows.
a. During ECO-NAVI operation :
After ECO-NAVI Lamp flashes 3 times slowly, turn
on the lamp.
b. While all of preconditions for ECO NAVI control
are met :
After ECO-NAVI Lamp flashes 3 times slowly, turn
off the lamp.
c. While one of preconditions for ECO NAVI control
are not met :
ECO-NAVI Lamp do not flash (keep to turn off the
lamp).
• While setting in ECO NAVI Lamp Disable, the above-
mentioned ECO NAVI operation is not performed.
3. Stored volume determination
• It is determined the increase in the volume of storage by
the difference of stored volume values between this time
and last time.
• Stored volume values calculate based on the input volt-
age of Storage sensor while turning on each LED.
• If {H65} is recorded in the memory, Interior lamps (LED)
operation and ECO-NAVI Lamp operation are performed,
but stored volume determination is not performed. 
Even though {H65} is recorded and it can be performed nor-
mally, it is determined the increase in the volume of storage.
4.7.3.
Extension of defrosting cycle con-
trol
4.7.3.1.
Learning function control
Defrosting period is extended for 13-24 hours.
(Normal defrosting period : 13 hours)
Forecast your lifestyle pattern, and operate the defrosting dur-
ing the ABSENT hours.
4.7.4.
Learning function
1. How to determine whether people are "ABSENT" in the
room.
• Based on the total number of door opening and closing
(IC, FC and PC door), determine people are "ABSENT"
or "PRESENT" in the room every hour.
2. How to determine the thermal loading.
Based on the total number of door opening and closing
(IC and FC door), detection of stored volume, and tem-
perature (FCC sensor and PCC sensor), determine the
thermal loading.
• When the above all of conditions are not met, it is deter-
mined "Minor thermal loading".
• When the above any one of conditions are met, it is
determined "Major thermal loading".
3. Data storage
The data has stored for the past 3 weeks.
• Old data will be overwritten by the fresh data in four
weeks.
• When the power is off, the data is deleted (reset).
4. Analyze lifestyle patterns
• Continuous ABSENT period 
a. ECO-NAVI counts the number of door opening
and closing every hour for 3 weeks to judge each
hour as “PRESENT” or “ABSENT”.
b. Each hourly data is compared between 1st, 2nd,
and 3rd week in order to make weekly lifestyle pat-
tern data which consists of 168 hourly data. 
c. If there are two or three “ABSENT” in the same
hour of the same day for 3 weeks, the hour is
assumed to be “ABSENT ZONE”.
d. If “ABSENT ZONE” continues more than 3 times in
the lifestyle pattern data, the period is assumed to
be “Continuous ABSENT period”
• Minor thermal loading period
a. ECO-NAVI memorizes the data (the number of
door opening and closing, etc) every hour for 3
weeks to judge each hour as "Major thermal load-
ing" or "Minor thermal loading".
b. Each hourly data is compared between 1st, 2nd,
and 3rd week in order to make weekly lifestyle pat-
tern data which consists of 168 hourly data. 
c. If there are two or three "Minor thermal loading" in
the same hour of the same day for 3 weeks, the
hour is assumed to be “Minor thermal loading
zone”.
d. If “Minor thermal loading zone” continues more
than 3 times in the lifestyle pattern data, the period
is assumed to be “Minor thermal loading period”
PC Temperature setting 
{2}
FC Temperature setting 
{2}
FRESH FREEZING
OFF
QUICK ICE MAKING
OFF
Notice indicator
No displayed
The total number of door 
opening and closing
Determination
1 or less
“ABSENT" in the room
2 or more
"PRESENT" in the room
Total number of door opening and closing (IC and FC door) is 2 or 
more times.
The increase in the volume of storage is detected. 
(refer to the PC stored volume determination control)
Following condition has continued for 5 minutes.
Temperature (FCC sensor) > Compressor operated, plus 3°C
Following condition has continued for 5 minutes.
Temperature (PCC sensor) > Damper thermostat opened, plus 3°C
Page of 97
Display