Panasonic NC-PH22WTW / NC-PH30WTW Service Manual ▷ View online
- 5 -
3. PROBLEM CHECKING
3.1 Thermo Pot performance test mode
Please follow check operating detail below, before
start to check the problems.
start to check the problems.
LED symbol for this instruction show as below.
How to operate
1. Pour approx. 1000 ml water into the container.
2. Supply with 220V electric power.
2. Supply with 220V electric power.
220V
Instruction
1. Long boil/Reboil LED will be lighted and
208F/98C LED will be blink and start to boil
water.
208F/98C LED will be blink and start to boil
water.
2. After approx. 9~10 min. 208F/98C LED will be
lighted and change to keep warm state.
lighted and change to keep warm state.
3.1.1 Boiling and Keep warm test
Blink
Lighted
Water supply mark
Approx. 1000 ml.
NC - PH30
4
4
NC-PH22, NC-PH30
- 6 -
How to operate
1. Set Keep warm to 98.
2. Press “Long Boil/Reboil” pad once or twice
to keep warm.
2. Press “Long Boil/Reboil” pad once or twice
to keep warm.
Operating detail
1. Long Boil/Reboil LED will be lighted and
208F/98C LED will be blink and start to boil
water.
208F/98C LED will be blink and start to boil
water.
2. 208F/98C LED will be lighted in approx. 2 min.,
later.
later.
If press “Long Boil/Reboil” pad once.
Operating detail
1. Long Boil/Reboil LED and 208F/98C LED will
be blink and start to boil water.
be blink and start to boil water.
2. After approx. 7 min., 208F/98C LED will be
lighted.
lighted.
If press “Long Boil/Reboil” pad twice to
eliminate chlorine.
3.1.2 Reboil, Long boil and Keep warm
test
test
Press this pad
NC-PH22, NC-PH30
4
4
4
4
4
- 7 -
1. Remove 2 tapping screws and 1 truss head
screw from bottom plate.
2. Remove 1 screw and sleeve from body.
3. Remove white, orange lead wire and earth
wire from peg frame.
4. Remove body off.
5. Remove waterproof cover B.
screw from bottom plate.
2. Remove 1 screw and sleeve from body.
3. Remove white, orange lead wire and earth
wire from peg frame.
4. Remove body off.
5. Remove waterproof cover B.
3.2 Dismantle procedure for failure
diagnotics
diagnotics
Tapping screw
(M4 x 12)
Truss head screw
Bottom plate
Sleeve
Screw A
Waterproof
cover B
cover B
Body
Do not do maintennance and re-use if copper
pattern on PCB is broken.
pattern on PCB is broken.
Microcomputer in thermo pot, may break
down by static electricity from clothes,
human body, workbenches, etc., when
touch or wonder to touch should to
ground humnan body with several M
down by static electricity from clothes,
human body, workbenches, etc., when
touch or wonder to touch should to
ground humnan body with several M
Ω.
Note
CAUTION
NC-PH22, NC-PH30
3.3 Check points
Check point-1
4
Boiling heater
(Approx. 70
Ω)
Thermistor (complete)
Approx. 20˚C
Approx. 45kΩ
Lead wire assy E
(0
Ω)
Keep warm heater
(Approx. 430
Ω)
Thermal fuse comp.
(0
Ω)
- 8 -
3.4 Failure diagnostics chart
3.4.1 No power. (There is no power indication)
Replace the Container comp.
Is there connection across the keep warm heater?
(approx. 430
(approx. 430
Ω) (between the brown and the yellow
portions)
Keep warm heater
Replace the Control unit A (bottom).
Is there connection in the lead wire assy E? (0
Ω)
When the above parts are normal
Replace the Control unit B (operation).
When the above parts are normal
Replace the Lead wire assy E.
Lead wire assy E
Replace the Power cord.
Is there connection in the power cord? (0
Ω)
Power cord
Replace the Thermal fuse comp.
Is there connection between the blue lead wire on
the peg frame and the CN3 connector of the control
unit A? (0
the peg frame and the CN3 connector of the control
unit A? (0
Ω)
Thermal fuse comp.
Action
Diagnostics Method
Check
The items in the Check correspond to those shown in Check Point on P. 7.
3.4.2 Water is not boiling. (Water comes out)
Replace the Container comp.
Is there connection across the boiling heater?
(approx. 70
(approx. 70
Ω) (between the blue and the white
portions)
Boiling heater
Replace the Control unit A (bottom).
When the above parts are normal
Action
Diagnostics Method
Check
The items in the Check correspond to those shown in Check Point on P. 7.
NC-PH22, NC-PH30
3.4.4 Long Boil/Reboil LED and 208F/98C LED are lighted up alternately.
(Overheating protection mode / Bottom thermistor disconnection mode)
(Overheating protection mode / Bottom thermistor disconnection mode)
Supply water and press the Long Boil/Reboil pad.
Is there water inside?
Action
Diagnostics Method
Check point
The items in the Check correspond to those shown in Check Point on P. 7.
Replace the Control unit B (operation).
Replace the Thermistor assy.
Is there connection across the Thermistor assy?
(approx. 20˚C : approx. 45K
(approx. 20˚C : approx. 45K
Ω)
(between the orange and the orange portions)
Thermistor assy.
Replace Lead wire assy E.
Is there connection in the lead wire assy E? (0
Ω)
Lead wire assy E
Replace the Control unit A (bottom).
When the above parts are normal
When the above parts are normal
Action
Diagnostics Method
Check
3.4.3 Hot water cannot poured out or water flow is obstructed. (Water is boiled)
Open the lid once and close it again before pouring
out the hot water.
out the hot water.
After the water has been boiled, the boiling bubbles may enter the
pump and obstruct the hot water from pouring out smoothly for a
little while.
pump and obstruct the hot water from pouring out smoothly for a
little while.
Action
Diagnostics Method
Check point
Click on the first or last page to see other NC-PH22WTW / NC-PH30WTW service manuals if exist.