Panasonic EP-1270-W0 Service Manual ▷ View online
- 29 -
- 30 -
- 31 -
10.
How to check the pressure
10.1. Air bag and the Pump block
1.
Cut the Insulated tie of the Hose plug and remove the
Hose plug
Hose plug
2.
Insert the Hose of the Pressure gauge to the T-shape
joint.
3.
Insert the hose to the end of the hose that you check
the air pressure.
- 32 -
4.
Push the On/off button and push the Leg massage button
and check the maximum value in two minutes.
5. Check the pressures at three levels by the intensity
adjustment of the Controller. If the pressure values are in
the range of the tolerance, the Air bag and the Pump unit
are normal.
* Each Air bags are checked as follows:
- Leg Air bag large (right side brown hose with line)
Strong 22.5±7
Medium 13.7±7
Weak 6±4
- Leg Air bag small/front (left side black hose with line)
Strong 24±7
Medium 14.5±7
Weak 8±5
- Leg Air bag small/middle (left side black hose without line)
Strong 25.5±7
Medium 15.5±7
Weak 8±5
- Leg Air bag small/back (right side brown hose without line)
Strong 21.5±7
Medium 12.5±7
Weak 7±4
Click on the first or last page to see other EP-1270-W0 service manuals if exist.