3 Maintenance, Adjustments and Check Points
3.1
Required Tools 
3.2
Periodic Maintenance Points
No.
Tool
No.
Tool
1
Soft Cloth
7
Pliers
2
Isopropyl Alcohol
8
Cotton Swab
3
Phillips Screwdriver (#2)
9
Brush
4
Stubby Phillips Screwdriver (#2)
10
KS-660 - Conductive Grease
5
Blade-tip Screwdriver (3/32 in)
11
Molykote EM-50L Grease (Dow Corning)
6
Tweezer
47
3.3
Periodic Maintenance Check List
The chart outlined below is a general guideline for maintenance. The example list is for an average usage of 50 transmitted and 
received documents per day. Needless to say, the environmental conditions and actual use will vary these factors.
The chart below is for reference only.
Note
The number of pages is based on the ITU-T Image No. 1 test chart at Standard resolution and Multi-Copy mode.
Transmitting mechanism parts
Cleaning
Replacement / Adjustment
Cycle
Method
Cycle
Method
ADF Roller (323)
3 months
Page 27
3-5 years(30,000 documents) Page 30
Separation Rubber (229)
3 months
Page 21
1-3 years(10,000 documents) Page 21
Pre-Feed Roller (325)
3 months
Page 27
3-5 years(30,000 documents) Page 30
Mirrors (337 and 338)
12 months
Page 28
-
Page 28
Verification Stamp (336)
-
-
5,000 documents
Page 31
Feed Roller (328)
3 months
Page 27
3-5 years(30,000 documents) Page 30
ADF Transmit Motor (346)
-
-
5 years
Page 30
Eject Roller (330)
3 months
Page 27
3-5 years(30,000 documents) Page 30
Latch (302)
12 months
-
-
-
Toner Cartridge
-
-
10,000 pages (See Note)
-
Feed Roller (618)
12 months or  10,000 
documents
Alcohol
-
Page 41
Clutch Gear Assembly (660)
12 months or  10,000 
documents
Alcohol
-
Page 41
Paper Feed Solenoid (744)
12 months or  10,000 
documents
Alcohol
-
Page 41
Bias Transfer Roller (630)
12 months or  10,000 
documents
-
30,000 documents
Page 33
Fuser Unit (431)
When replacing  Print 
Cartridge
Cleaning chart
50,000 documents
Page 35
Paper Feed Roller (746)
12 months or  10,000 
documents
Alcohol
30,000 documents
Page 41
Fuser Lamp (408)
-
-
50,000 documents or 2-5 
years
Page 35
Fuser Roller (414)
12 months or  10,000 
documents
Alcohol
-
Page 37
Pressure Roller (409)
12 months or  10,000 
documents
Alcohol
-
Page 37
Fan (622)
-
-
3-5 years
Page 41
Printer Motor (650)
-
-
5 years
Page 39
48
3.4
Updating the Firmware
Unlike other machines with removable EPROM (Erasable Programmable ROM), this machine is equipped with an F-ROM (Flash 
ROM).  F-ROM offers the flexibility of quick and easy firmware updates, creation of a master firmware card, backup and restore of 
firmware and machine parameters.  
The following is the basic procedure to update the firmware of the machine. The details are described in the Firmware Update Kit 
User’s Guide. (Order No.: UE-406053 and UE-406055)
3.4.1
Creating a Master Firmware Card
A.  Utilizing the Firmware Update Kit.
1.   Install the Firmware Update Kit.
2.   Install a Flash Memory Card (2 MB or higher) into the machine.
3.   Follow the instructions included in the Firmware Update Kit User’s Guide.
B.  Copy the Firmware from an Existing Machine
1.   Turn the Power Switch to the OFF (O) position.
2.   Install a Flash Memory Card (2 MB or higher) into the machine.
3.   Turn the Power Switch to the ON (I) position.
4.   Perform the Service Mode 9-2 (Firmware Backup).
5.   The firmware is copied into the Flash Memory Card.
6.   After the backup is completed, press "STOP" to return to standby.
7.   Turn the Power Switch to the OFF (O) position.
8.   Remove the Master Firmware Card that you just created from the machine.
9.   Turn the Power Switch to the ON (I) position.
10. Use this Master Firmware Card to update the firmware on other machines.
3.4.2
Updating the Firmware using the Master Firmware Card
1.   Before starting, print the Fax and Function Parameter Lists.
2.   Turn the Power Switch to the OFF (O) position.
3.   Install the appropriate Master Firmware Card into the machine.
4.   Turn the Power Switch to the ON (I) position.
5.   Perform the Service Mode 9-1 (Firmware Update).
6.   The firmware is copied into the machine.
7.   After the update is completed, the machine reboots itself and returns to standby.
8.   Perform the Service Mode 6 (Parameter Initialization).
9.   Turn the Power Switch to the OFF (O) position.
10. Remove the Master Firmware Card from the machine.
11. Turn the Power Switch to the ON (I) position.
12. Reprogram the Fax and/or Function Parameters according to the lists printed in Step 1 above if the settings 
                     are other than factory default.
3.4.3
Erasing the Master Firmware Card
1.   Turn the Power Switch to the OFF (O) position.
2.   Install the Master Firmware Card into the machine.
3.   Turn the Power Switch to the ON (I) position.
4.   Perform the Service Mode 9-5 (PC 
 Flash Card).
5.   The firmware is erased from the card and the following message is shown on the display:
6.   Press "STOP" twice to return to standby.
7.   Turn the Power Switch to the OFF (O) position.
8.   Remove the blank Flash Memory Card from the machine.
9.   Turn the Power Switch to the ON (I) position.
PRESS SET TO START
READY TO PROGRAM
49
3.4.4
Firmware Version
3.5
ADF Pressure
• When documents multi-feed, move the pressure Adjusting Lever to the 3 (H) position.
• When documents do not feed properly, move the Pressure Adjusting Lever to the 1 (L) position.
Position
Pressure of separator
Situation
1 (L)
Low
When the documents misfeed
2 (M)
Medium
Normal Position (Factory set position)
3 (H)
High
When the documents multi-feed
UF-895
A
L
V02100
AB
Country Code
   
Firmware Version (V0.2100)
Language Code
  
Firmware Type
   A : Standard
   B : Optional
Model Number
Page of 127