41
2.2.13.
MJR PC Board (1003), Power Supply Unit (1002) 
Caution:
Make sure the Power Cord (1108) is unplugged.
Note:
If removing only the Power Supply Unit, skip 
steps (3), (4) and (5).
(1) Remove the Rear Cover (105) (Refer to 2.2.12.).
(2) Disconnect the Connectors (CN28 and 29) on 
the MJR PC Board.
(3) Remove 2 Screws (19).
(4) Release the Latch Hook of Locking Card 
Spacer (405).
(5) Remove the MJR PC Board (1003).
(6) Remove 5 Screws (19).
(7) Remove the L Power Plate (401).
(8) Disconnect the Connectors (CN101102103
201 and 202) on the Power Supply Unit (1002).
(9) Remove 4 Screws (19).
(10) Remove 1 Screw (19) and 1 Washer (G8).
(11) Remove the Power Supply Unit (1002).
(2)
(3)
(4)
(5)
(6)x5
(7)
(9)x4
(10)
(11)
(8)
(8)
42
2.2.14.
Fuser Unit, Thermistor Assembly (728)
(1) Remove the Rear Cover (Refer to 2.2.12.).
(2) Remove 1 Screw (19).
(3) Remove the Fuser Top Cover (733).
(4) Disconnect the Connectors CN85 and CN87 on 
the SNS4 PC Board (1007).
(5) Disconnect the Connector CN102 on the Power 
Supply Unit (423).
(6) Remove 1 Screw (4N).
(7) Remove the FG1 Harness (629).
(8) Remove 4 Screws (19).
(9) Remove the Fuser Unit.
(10) Remove 1 Screw (1Q).
(11) Remove the Thermistor Assembly (728).
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
43
2.2.15.
Fuser Lamp (732), Exit Roller (719), Fuser Roller (709), 
Pressure Roller (706)
(1) Remove the Rear Cover (Refer to 2.2.12.) an
the Fuser Unit (Refer to 2.2.14.).
(2) Remove 1 Screw (4N).
(3) Remove the PSU-Fuser Harness (1028) and 
Fuser Lamp Terminal B (731).
(4) Remove the Fuser Lamp (732).
Caution:
When reinstalling the Fuser Lamp, make sure that 
the Fuser Lamp is inserted into the Fuser Unit as 
illustrated. Do not touch the glass portion of the 
Fuser Lamp with bare hands. Grease from 
fingerprints will shorten its life cycle, use isopropyl 
alcohol to clean fingerprints.
Caution:
When reinstalling the Fuser Lamp, make sure that 
both ends of the Fuser Lamp fits into the projected 
area of the Fuser Lamp Terminal A (724) and the 
Fuser Lamp Terminal B (731).
(5) Remove the E22 Gear (722).
Caution:
You may need to use force to pull out the Gear.
(6) Remove the Right and Left P3.5L11.2 
Bushings (720 and 721).
(7) Remove the Exit Roller (719).
(8) Remove 2 Screws (4N).
(9) Remove the Fuser Cover  (723).
(2)
(3)
(4)
White
Black
(6)
(7)
(5)
(8)
(9)
44
(10) Remove 2 Pressure Springs (708).
(11) Remove the E14 Gear (714).
Caution:
You may need to use force to pull out the Gear.
(12) Remove the 2 E18 Gears (713).
(13) Remove 2 C-Rings (712).
(14) Remove the E24 Drive Gear (711).
(15) Remove 2 P17L6.8 Bushings (710).
(16) Remove the Fuser Roller (709).
Caution:
Do not scratch the surface of the Fuser Roller 
when removing or reinstalling it.
(17) Remove 1 Screw (4N).
(18) Remove the Lower Paper Exit Guide (703).
(10)
(13)
(15)
(11)
(12)
(14)
(16)
(17)
(18)
Page of 127