Panasonic UF-580 / UF-590 / UF-780 / UF-790 / UF-5100 / UF-6000 / UF-6100 Service Manual ▷ View online
113
4.4.5.
Vertical Dark Lines
START
No
Yes
Check the Scanner mechanism.
Is the Toner Cartridge
operational?
operational?
No
Yes
Are there any foreign particles
or stains on the BTR?
or stains on the BTR?
Yes
No
2. Replace the Toner Cartridge.
1. Clean the BTR with a soft, dry
cloth.
2. Replace the BTR.
cloth.
2. Replace the BTR.
Is the Laser Unit (LSU)
normal?
normal?
No
Yes
Replace the Laser Unit (LSU).
END
No
Yes
Clean or replace the rollers.
Paper Travel
P
Are the Fuser and Pressure
Roller surfaces clean?
Roller surfaces clean?
Is the printout in Service
Mode 3 normal?
Mode 3 normal?
1. Clean the Corona Wire
as illustrated below.
as illustrated below.
114
4.4.6.
Horizontal Dark Lines
START
Is the printout in Service
Mode 3 normal?
Mode 3 normal?
Yes
No
Replace the Toner Cartridge.
1. Clean the BTR with a soft,
dry cloth.
dry cloth.
2. Replace the BTR.
No
Yes
Check the Scanner mechanism.
Is the Toner Cartridge
operational?
operational?
No
Yes
Is the Laser Unit (LSU) normal?
No
Yes
Replace the Laser Unit (LSU).
Is the Power Supply Unit
1. Check all connectors and
voltages on the Power
Supply Unit .
2. Check the Connector and
voltage on the Power
Supply Unit.
voltages on the Power
Supply Unit .
2. Check the Connector and
voltage on the Power
Supply Unit.
3. Replace the Power Supply
Unit.
Unit.
Yes
No
END
No
Yes
Clean or replace the rollers.
Paper Travel
P
Are there any foreign
particles or stains on the BTR?
particles or stains on the BTR?
Are the Fuser and Pressure
Roller surfaces clean?
Roller surfaces clean?
normal?
115
4.4.7.
Dark Background
Is the Laser Unit (LSU) normal?
No
Yes
Replace the Laser Unit (LSU).
START
No
Yes
Check the Scanner mechanism.
Is the Toner Cartridge
operational?
operational?
No
Yes
Is the recording paper damp?
Yes
No
Replace the recording paper.
Replace the Toner Cartridge.
Is the Power Supply Unit
(HVPS) normal?
(HVPS) normal?
1. Check all connectors and
voltages on the Power Supply
Unit (HVPS).
voltages on the Power Supply
Unit (HVPS).
2. Replace the Power Supply Unit
(HVPS).
(HVPS).
Yes
No
END
No
Yes
Clean or replace the rollers.
Paper Travel
P
Are the Fuser and Pressure
Roller surfaces clean?
Roller surfaces clean?
Is the printout in Service
Mode 3 normal?
Mode 3 normal?
116
4.4.8.
Light Print
No
Yes
START
No
Yes
Is the printout in Service
Mode 3 normal?
Mode 3 normal?
Check the Scanner mechanism.
Is the Toner Cartridge
operational?
operational?
No
Yes
Is the recording paper damp?
Yes
No
Replace the paper.
Replace the Toner Cartridge.
Are there any foreign particles or
stains blocking the Laser Unit
path?
stains blocking the Laser Unit
path?
Yes
No
1. Remove the particles from the
laser beam path or clean the stains.
2. Replace the LSU.
laser beam path or clean the stains.
2. Replace the LSU.
Is the Power Supply Unit (HVPS)
normal?
normal?
1. Check all connectors and
voltages on the Power Supply Unit
(HVPS).
2. Replace the Power Supply Unit
(HVPS) .
voltages on the Power Supply Unit
(HVPS).
2. Replace the Power Supply Unit
(HVPS) .
Yes
No
Clean or replace the rollers.
Paper Travel
Are the Fuser and Pressure Roller
surfaces clean?
surfaces clean?
Click on the first or last page to see other UF-580 / UF-590 / UF-780 / UF-790 / UF-5100 / UF-6000 / UF-6100 service manuals if exist.