Refer to JOURNAL 3 in PRINTOUT EXAMPLE(P.113).
(6) ENCODE
Compression Code: MH/MR/MMR
(7) MSLT
MSLT means Minimum Scan Line Time. Used only at
the factory.
(8) EQM
EQM means Eye Quality Monitor. Used only at the
factory.
(9) ERROR LINE (RX)
When an error occurs while receiving a fax, this shows
the number of error lines.
(10) MAKER CODE
This shows a 2 digit code of the other party´s fax
machine brand.
0E: "KX" model
00: Unknown
79: "UF" model
19: "Xerox" model
2.4.7.2. JOURNAL 3
Description
2.4.7.3. PRINTOUT EXAMPLE
113
KX-FLM553RU
114
KX-FLM553RU
2.5. TEST FUNCTIONS
The codes listed below can be used to perform simple checks of some of the unit’s functions. When complaints are received
from customers, they provide an effective tool for identifying the locations and causes of malfunctions.
Test Mode
Type of Mode
Code
Function
Operation after
code input
MOTOR TEST
Service Mode
“5” “5” “6”
0: Recording paper feed
1: Document feed (STANDARD)
2: Document feed (FINE)
3: Document feed (SUPER FINE)
START
MODEM TEST
Service Mode
“5” “5” “4”
Telephone line circuit is connected automatically, output the following signals on the
circuit line.
1) OFF 2) 14400bps 3) 12000bps 4) 9600bps 5)7200bps
6) 4800bps 7) 2400bps 8) 300bps 9) 2100Hz 10)1100Hz
START
ROM CHECK
Service Mode
“5” “5” “1”
Indicates the version and checks the sum of the ROM.
START
SCAN CHECK
Service Mode
“5” “5” “5”
Turns on the LEDs of the CIS and operates the read systems.
Refer to CIS (contact Image Sensor) SECTION (P.94).
START
LCD CHECK
Service Mode
“5” “5” “8”
Checks the LCD indication.
Illuminates all the dots to check if they are normal.
Refer to OPERATION PANEL SECTION (P.89).
START
DTMF
SINGLE
TEST
Service Mode
“5” “5” “2”
Outputs the DTMF as single tones. Used to check the frequencies of the individual
DTMF tones. Refer to DTMF SINGLE TONE TRANSMIT SELECTION (P.117).
1....ON
2....OFF
LED CHECK
Service Mode
“5” “5” “7”
All LEDs above the operation panel board flash on and off, or are illuminated.
START
KEY CHECK
Service Mode
“5” “6” “1”
Checks the button operation.
Indicates the button code on the LCD while the button is pressed. Refer to BUTTON
CODE TABLE 
(P.117).
START (any key)
MEMORY CLEAR
Service Mode
“5” “5” “0”
To reset the value to the default one, except the top margin (#853),left margin
(#854),time/day (#001),logo (#002),Fax No.(#003),History and Directory.
Please restart a power supply after clearing a memory.
START
High Voltage Power
Supply Board
CHECK
Service Mode
“6” “2” “8”
Refer to HIGH VOLTAGE VALUE CHECK POINT (P.116).
START
SENSOR CHECK &
VOX CHECK
Service Mode
“8” “1” “5”
First of all, press the copy button, and confirm the action of ON/OFF.
For each sensor’s operation , refer to SENSORS AND SWITCHES SECTION
(P.197).
START
D S C P R E D T * 3F * * * * *
: LCD DISPLAY
D: Document sensor
:When a document is insert.
S: Scanner read Pos.
:When a document is insert.
C: Cover of Printer
:When the top cover is open.
P: Paper exist
:When recording paper exists.
R: Pick up paper
:When recording paper exists.
E: Exit sensor on
:When exist sensor is on.
D: Developer exist
T: Toner exist
*: None
3F: Temperature of fuser unit (2
digits)
:Refer to HEAT LAMP CONTROL
CIRCUIT 
(P.209).
*: None
*: None
*: None
*: None
*: None
PRINT TEST
PATTERN
Service Mode
“8” “5” “2”
1. Press “852” then the SET key in the service mode.
2. As “PATNO = ” is displayed on the LCD, enter the test pattern No. and press the
SET key.
3. When “No. = “ is displayed on the LCD, enter the printing number and press the
SET key. (Press “00” for the infinite printing.)
4. “MODE” is displayed on the LCD. Press “0” to start printing or press “1” to go to the
next screen.
5. When “1” is pressed at MODE, “INTVL = “ is displayed on the LCD. Enter the
printing interval (00~99 sec).
6. The printing repeats the designated number of times at the programmed printing
intervals.
START
Note:
The numbers in the boxes (XXX) indicate the keys to be input for the various test modes.
115
KX-FLM553RU
2.5.1. HIGH VOLTAGE VALUE CHECK POINT
Measurement Procedure
 1. Open the TOP cover.
 2. Remove the developing unit, if it is equipped.
 3. Open the TOP cover, and turn ON the TOP cover SW.
(Push the TOP cover SW with a sharp-tipped insulator or insert folded paper, etc. to the slit.)
 4. The unit enters the service mode when the TOP cover is open, then push *628.
(Don´t push the START button.)
 5. Touch the output terminals under test with the high voltage probes.
 6. Push the START button.
(This causes to output high voltage from each terminal, so be careful not to touch them. The sound "Pi Pi Pi" warns that the
high voltage is outputting.)
 7. When the measurement is finished, push the STOP button.
(The high voltage output is stopped.)
 8. Repeat the items No. 5~7 until the measurement is finished.
 9. When the measurement is finished, turn OFF the TOP cover SW.
Output voltage of each terminal
No.
BIAS Name
Specified output voltage
The range of specified output voltage
CHG (Charge)
-1200V
-1200V± 35V
DEV (Developing)
-350V
-350V± 15V
SUP (Supply)
-550V
-550V± 50V
TRA (Transfer)
-1200V
-1200V± 100V
* As for the High Voltage test equipment, FLUKE 85 (MULTIMETER)+ HIOKI (HV PROBE 9014) or the equivalent should be