29
KX-FLC413RU
Note 1 - Standard facsimile units conforming to T.2 must have the following capability: Index of cooperation (IOC)=264.
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
21, 22, 23
 
(0, 0, 0)
 
(0, 0, 1)
 
(0, 1, 0)
 
(1, 0, 0)
 
(0, 1, 1)
 
(1, 1, 0)
 
(1, 0, 1)
 
(1, 1, 1)
Minimum scan line time capability of the receiver
 
20 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
40 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
10 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
5 ms at 3.85 l/mm: T
7.7
 = T
3.85
 
10 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
 
20 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
 
40 ms at 3.85 l/mm: T
7.7
 = 1/2 T
3.85
 
0 ms at 3.85 l/mm: T
7.7
 = T
3.85
Minimum scan line time
 
20 ms
 
40 ms
 
10 ms
 
5 ms
 
 
 
 
 
 0 ms
24
Extend field
Extend field
25
2400 bit/s handshaking
2400 bit/s handshaking
26
Uncompressed mode
Uncompressed mode
27
Error correction mode
Error correction mode
28
Set to “0”.
Frame size 0 = 256 octets     1 = 64 octets
29
Error limiting mode
Error limiting mode
30
Reserved for G4 capability on PSTN
Reserved for G4 capability on PSTN
31
T.6 coding capability
T.6 coding enabled
32
Extend field
Extend field
33
 
(0)
 
(1)
Validity of bits 17, 18
 
Bits 17, 18 are valid
 
Bits 17, 18 are invalid
Recording width
 
Recording width indicated by bits 17, 18
 
Recording width indicated by this field bit information
34
Recording width capability 1216 picture elements along
scan line length of 151 ± mm 1%
Middle 1216 elements of 1728 picture elements
35
Recording width capability 864 picture elements along scan
line length of 107 ± mm 1%
Middle 864 elements of 1728 picture elements
36
Recording width capability 1728 picture elements along
scan line length of 151 ± mm 1%
Invalid
37
Recording width capability 1728 picture elements along
scan line length of 107 ± mm 1%
Invalid
38
Reserved for future recording width capability.
39
Reserved for future recording width capability.
40
Extend field
Extend field
41
R8
×15.4 lines/mm
R8
×15.4 lines/mm
42
300
×300 pels/25.4 mm
300
×300 pels/25.4 mm
43
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
R16
×15.4 lines/mm and/or 400×400 pels/25.4 mm
44
Inch based resolution preferred
Resolution type selection
 
“0”: neuritic based resolution
 
“1”: inch based resolution
45
Metric based resolution preferred
Don’t care
46
Minimum scan line time capability for higher resolutions
 
“0”: T
15.4
 = T
7.7
       “1”: T
15.4
 = 1/2T
7.7
Don’t care
47
Selective Polling capability
Set to “0”.
48
Extend field
Extend field
Signal
Identification Signal Format
Function
Training 1
———————
A fixed pattern is transmitted to the receiving side at a speed (2400
to 14400 bps) designated by DCS, and the receiving side optimizes
the automatic equalizer, etc., according to this signal.
Bit No.
DIS/DTC
DCS
30
KX-FLC413RU
b. Redundancy Compression Process Coding Mode
This unit uses one-dimensional MH format.
TCF
 
(Training Check)
———————
Sends 0 continuously for 1.5 seconds at the same speed as the
training signal.
CFR 
 
(Confirmation to Receive)
X0100001
Notifies the sending side that TCF has been properly received. If
TCF is not properly received, FTT (Failure To Train) X0100010 is
relayed to the sender. The sender then reduces the transmission
speed by one stage and initiates training once again.
Training 2
———————
Used for reconfirming the receiving side like training 1.
Image Signal
Refer to the next page.
———————
RTC
 
(Return to Control)
———————
Sends 12 bits (0...01 
× 6 times) to the receiver at the same speed as
the image signal and notifies completion of transmission of the first
sheet.
EOP
 
(End of Procedure)
X1110100
End of one communication
MCF
 
(Message Confirmation)
X0110001
End of 1 page reception
DCN
 
(Disconnect)
X1011111
Phase E starts.
MPS
 
(Multi-Page Signal)
X1110010
Completion of transmission of 1 page. If there are still more docu-
ments to be sent, they are output instead of EOP. After MCF recep-
tion, the sender transmits an image signal of the second sheet.
PRI-EOP
 
(Procedural Interrupt-EOP)
X1111100
If there is an operator call from the sender, it is output after RTC.
PIP
 
(Procedural Interrupt Positive)
X0110101
This is output when an operator call is received.
Signal
Identification Signal Format
Function
31
KX-FLC413RU
7.5.
NCU Section
7.5.1.
General
This section is the interface between the telephone line and external telephone. It is composed of an EXT. TEL line relay (RLY200),
bell detection circuit, TAM interface circuit, line amplifier and side tone circuits and a multiplexer.
7.5.2.
EXT. TEL. Line Relay (RLY200)
1. Circuit Operation
Normally, this relay switches to the external telephone side (break) and switches to the open side (make) while OFF-HOOK.
{ IC4 (83) High Level
→CN921 (5) High Level} →CN500 (5) High Level→Q210 ON→RLY200 (ON)→(make)
{ IC4 (12) High Level
→CN921 (10) High Level} →CN500 (10) High Level→PC203 ON→Q206 (ON)→(make)
7.5.3.
Bell Detection Circuit
1. Circuit Operation
The signal waveform for each point is indicated below. The signal (low level section) input to pin 6 of gate array  IC107 on the
digital board is read by ASIC and judged as a bell.
TEL LINE
→PC205 (1, 2 - 4)→IC4 (10)
7.5.4.
Calling Line Identification Circuit
1. Function
This unit is compatible with the Caller ID service offered by your local telephone company. To use this feature, you must sub-
scribe to a Caller ID service. The data for the caller ID from the telephone exchange is sent during the interval between the
first and second rings of the bell signal. The data from the telephone exchange is a modem signal which is modulated in an
FSK (Frequency Shift Keying) format. Data “0” is a 1200 Hz sine wave, and data 1 a 2200 Hz sine wave.
There are two type of the message format which can be received: i.e.the single data message format and multiple data mes-
sage format.
The multiple data format allows to transmit the name and data code information in addition to the time and telephone number
data. 
When there is multiple data in the unit, the name or telephone number are displayed.
2. Circuit Operation
FSK signal of the caller ID signal input from TEL LINE is processed with BBIC (IC4).
Refer to Check Sheet (P.120) for the route of caller ID signal.
32
KX-FLC413RU
7.5.5.
Line Amplifier and Side Tone Circuit
1. Circuit Operation
The reception signal output from the line transformer T201 is input to pin (2) of IC204 via C244, R237 and then the signal is
amplified at pin (1) of IC204 and sent to the reception system.
The transmission signal goes through L225 and enters IC204-pin (6), where the signal is amplified. Then, it is output from pin
(7) of IC204 and transmitted to T201 via C248, R245, R244. Without a side tone circuit, the transmission signal will return to
the reception amplifier via R237, C244. When the side tone circuit is active, the signal output from IC204 pin (7) passes
through R241, R233, C234, R229 and L220 and goes into the amplifier IC204 pin (3). This circuit is used to cancel the trans-
mission return signal.
The TX signal is output to the circuit analog the route from the IC204 7 pin
→C248→R245→R244→T201→TEL LINE.
However, if balance is lost in the bridge, a voltage occurs between the IC209 6 pin and 5 pin and a side tone results, because
the balance cannot be maintained completely at all frequencies in the audio range some side tone always occur.
7.5.6.
Remote Fax Activation Circuit
1. Function
Another telephone connected to same line activates the unit to the FAX mode by using a DTMF signal.
2. Signal Path
Refer to Check Sheet (P.120).