DOWNLOAD Panasonic KX-FLC413RU Service Manual ↓ Size: 8.86 MB | Pages: 127 in PDF or view online for FREE

Model
KX-FLC413RU
Pages
127
Size
8.86 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / COMPACT LASER FAX
File
kx-flc413ru.pdf
Date

Panasonic KX-FLC413RU Service Manual ▷ View online

37
KX-FLC413RU
7.8.2.
Scan Motor Drive Circuit
1. Functions
This motor functions for main operations including FAX transmission.
This feed document paper synchronized for reading.
2. Motor operation
During motor driving, pin 25 of ASIC IC106 becomes a high level, and Q109, Q101 turns ON.
As a result, +24V is supplied to the motor coil.
Stepping pulses are output from ASIC IC106 pins, 21, 22, 23, 24, causing driver IC103 pins, 
16 ~ 13 to drive the motor coil.
The motor coil is energized sequentially in 2 phase increments, which causes a 1-step rotation.
A 1-step rotation feeds 0.065mm of document paper.
7.8.2.1.
Timing Chart
38
KX-FLC413RU
7.8.2.2.
Scan Motor (ADF Motor) Drive Circuit
DRIVE MODE
FUNCTION
MODE
PHASE PATTERN
SPEED
SCAN
FAX
STANDARD
2 phase
579pps 
SCAN
FAX/COPY
FINE/PHOTO
2 phase
579pps 
SCAN
FAX/COPY
SUPER FINE
1-2 phase
579pps 
SCAN
FAX/COPY
PHOTO WITH TEXT
2 phase
579pps
SCAN
DOC.PREFEED/EJECT
-
2 phase
579pps
STAND-BY
-
ALL PHASE OFF
-
39
KX-FLC413RU
7.9.
FAN Motor Section
This FAN is used to radiate heat in the unit.
The signal level at pin 92/94 of IC107 becomes high, the FAN is activated. In this case, the pulse signal as shown below input to
pin 91 of IC107 and the rotation of the FAN is detected.
7.9.1.
FAN Control
This unit is equipped with fan to prevent the developing device from rising in temperature while printing.
The air is inhaled from the right side of the unit.
The fan rotates at high speed (Approx. 3000 rpm) while printing (controlling the developing device). After printing is finished, it
rotates at low speed (Approx. 2200 rpm) when the temperature of the unit goes up over a fixed one or depending on the number
of printed papers (frequency).
While the fan is rotating at high speed, the voltage of Approx. 21 V is supplied to the fan, however, while rotating at low speed,
the supply voltage is decreased to Approx. 12V.
Each signal wave is as follows:
1. High-speed rotation (typ. 3000 rpm)
40
KX-FLC413RU
2. Low-speed rotation (typ. 2200 rpm)
7.10. Solenoid Drive Section
The solenoid drive circuit controls the pick-up clutch.
The solenoid is designed to be driven by +24V, driven by IC107-17 pin.
Diode D600 protects Q607 from backward voltage when the solenoid is driven.
Mode
IC107-17 pin
SOLENOID ON
high level
SOLENOID OFF
low level
Page of 127
Display

Click on the first or last page to see other KX-FLC413RU service manuals if exist.