12.3.6.1. CALL SERVICE 1
"CALL SERVICE 1" means that the polygon motor inside the LSU does not rotate.
The rotation of the polygon motor is detected by IC604-48pin (XREADY).
The rotation of the polygon motor is detected by IC604-48pin (XREADY).
122
KX-FLB813RU
12.3.6.2. CALL SERVICE 2
"CALL SERVICE 2" means that the synchronous signal out of the LSU cannot be detected.
The synchronous signal out of the LSU is detected by IC 604-59pin. (XHSYNC)
The synchronous signal out of the LSU is detected by IC 604-59pin. (XHSYNC)
Note:
As for the "Pulse" waveform of the above flow chart, see the timing chart.
123
KX-FLB813RU
12.3.6.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 604-21pin.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 604-21pin.
* When Call Service 3 is occurred, the cause can be distinguished by service mode 655.
Refer to P.120 for details.
Refer to P.120 for details.
124
KX-FLB813RU
12.3.6.4. CALL SERVICE 4
"CALL SERVICE 4" means that the FAN does not run or the running of the FAN cannot be detected normally.
The running of the FAN is detected by IC600-16 and 18pin. "CALL SERVICE 4" is displayed when it detects NG three times contin-
uously.
After repairing, copy three times.If “CALL SERVICE 4 “ is displayed,check again.
The running of the FAN is detected by IC600-16 and 18pin. "CALL SERVICE 4" is displayed when it detects NG three times contin-
uously.
After repairing, copy three times.If “CALL SERVICE 4 “ is displayed,check again.