DOWNLOAD Panasonic KX-FL513RU Service Manual ↓ Size: 6.38 MB | Pages: 127 in PDF or view online for FREE

Model
KX-FL513RU
Pages
127
Size
6.38 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / HIGH SPEED LASER FAX AND COPIER
File
kx-fl513ru.pdf
Date

Panasonic KX-FL513RU Service Manual ▷ View online

1.1.2. ERROR CODE TABLE
5
KX-FL513RU
1.2. ABOUT LEAD FREE SOLDER (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that
contains lead.
We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin, (Sn),
Silver, (Ag), and Copper, (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type of solder although, with some precautions, standard Pb solder can also be used.
Caution
     • 
• 
• 
• 
PbF solder has a melting point that is 50° ~ 70° F, (30° ~ 40°C) higher than Pb solder. Please use a soldering iron with
temperature control and adjust it to 700° ± 20° F, (370° ± 10°C). In case of using high temperature soldering iron, please
be careful not to heat too long.
     • 
• 
• 
• 
PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100°F, (600°C).
     • 
• 
• 
• 
If you must use Pb solder on a PCB manufactured using PbF solder, remove as much of the original PbF solder as possible
and be sure that any remaining is melted prior to applying the Pb solder.
     • 
• 
• 
• 
When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See figure, below).
1.2.1. SUGGESTED PBF SOLDER
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper,
(Sn+Ag+Cu), you can also use Tin and Copper, (Sn+Cu), or Tin, Zinc, and Bismuth, (Sn+Zn+Bi). Please check the manufac-
turer’s specific instructions for the melting points of their products and any precautions for using their product with other
materials.
The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3mm, 0.6mm and 1.0mm.
6
KX-FL513RU
1.3. HOW TO RECOGNISE THAT Pb FREE SOLDER IS USED
P.C.Boards marked as “PbF” use Pb Free solder. (See the figure below.)
Pb Free is not used the Power Supply Board of this unit.
(Example :Digital board)
CN612
1
8
E
L659
L661 L660
IC605
R70
L619
L618
C667
R708
L630
R611
F605
R736
L620
L621
R723
R613
R610
C717
C731
C694
L655
L643
L604
L606
L605
R767
R769
R768
L656
L657
H
Q609
75
51
50
26
25
1
76
100
C738
C668
RA610
RA609
D602
J600
8
1
9
IC610
Q613
C726
D607
D608
R737
E
Q620
16
L624
L625
L626
658
L653
L654
L642
C666
BAT600
PFUP1330YA
PbF
RA602
C672
C728
+24V
+3.3V/BAT
25
DIGITAL BOARD COMPONENT VIEW
Marked
Note : The “PbF” marked may be found on different areas of the same P.C.Board,depending on manufacture date.
7
KX-FL513RU
1.4. SAFETY PRECAUTIONS
 1. Before servicing, unplug the AC power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.5. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screw heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
1.6. FOR SERVICE TECHNICIANS
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
 1. Cover the plastic part´s boxes with aluminum foil.
 2. Ground the soldering irons.
 3. Use a conductive mat on the worktable.
 4. Do not touch the IC or LSI pins with bare fingers.
1.7. BATTERY CAUTION
CAUTION
There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Dispose used batteries according to the manufacturerís instructions:
The lithium battery is a critical component (type No. CR-2032/V9A). Please observe for the proper polarity and exact location
when replacing and soldering the replacement battery.
8
KX-FL513RU
Page of 127
Display

Click on the first or last page to see other KX-FL513RU service manuals if exist.