37
11.1.2.
Checking and Repairing of BDP/Digital P.C.B. Module
38
11.2. Adjustment of BDP/Digital P.C.B. Module
11.2.1.
Checking out symptoms and repair of BDP/Digital P.C.B. Module
When replacing or repairing the BD Drive unit alone or the Digital P.C.B. alone, please perform the work according to following
checking sequence.
39
11.2.2.
In the Case of Necessity the Adjustment
1. When the BD Drive is replaced.
2. When the Digital P.C.B. is replaced.
11.2.3.
List of Service Tools
11.2.3.1. Adjustment/Inspection Tools
11.2.3.2. Commercial Tools Required
11.2.4.
How to adjust the BDP/Digital P.C.B. Module
The adjustment may not resume. If interrupt the adjustment, start from the beginning phase.
Preparation:
Before starting the adjustment, install the adjustment software to PC and copy the SD DIAG software to SD card.
Note:
This adjustment software can be downloaded from “Support Information from NWBG/VDBG-AVC” web-site in “TSN system”,
together with instructions of “BD Drive Adjustment” including preparations and connections etc.
40
1. Connect the Serial cable (RFKZ0139) between serial port
connector (P51601) on the Digital P.C.B. and PC's serial
port.
• Confirm the PC’s serial port number (COM1, COM2,
etc.) connected to serial cable (RFKZ0139), the port
number may be set after this procedure.
2. Start the Adjustment software, then click the [Start(S)].
[Selection of Model Name]
3. Select the model number and click the [OK] button.
• If several other model names might appear, please
select the sure model number for the adjustment.
[Setting of Adjustment]
4. Click the [Utility] button.
5. Click the [COM Setup] button.
6. Select the COM number that connect the serial cable
(RFKZ0139) and click the [OK] button.
7. Click the [Exit] button.
8. Click the [Adjustment] button.