DOWNLOAD Panasonic DMC-LX1PP / DMC-LX1EB / DMC-LX1EG / DMC-LX1EGM / DMC-LX1GC / DMC-LX1GD / DMC-LX1GK / DMC-LX1GN / DMC-LX1GT / DMC-LX1SG Service Manual ↓ Size: 3.33 MB | Pages: 59 in PDF or view online for FREE

Model
DMC-LX1PP DMC-LX1EB DMC-LX1EG DMC-LX1EGM DMC-LX1GC DMC-LX1GD DMC-LX1GK DMC-LX1GN DMC-LX1GT DMC-LX1SG
Pages
59
Size
3.33 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-lx1pp-dmc-lx1eb-dmc-lx1eg-dmc-lx1egm-dmc-lx1gc.pdf
Date

Panasonic DMC-LX1PP / DMC-LX1EB / DMC-LX1EG / DMC-LX1EGM / DMC-LX1GC / DMC-LX1GD / DMC-LX1GK / DMC-LX1GN / DMC-LX1GT / DMC-LX1SG Service Manual ▷ View online

17
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
LENS
Lens drive
OIS
1800
1000 
PSD (X) error. Hall element (X axis) position detect error in OIS unit.
OIS Unit
2000 
PSD (Y) error. Hall element (Y axis) position detect error in OIS unit.
OIS Unit
3000 
GYRO (X) error. Gyro  (IC7102: X axis) detect error on Main C.B.A..
IC7102 (Gyro element) or IC6001 (VENUS 2)
4000 
GYRO (Y) error. Gyro  (IC7101: Y axis) detect error on Main C.B.A..
IC7101 (Gyro element) or IC6001 (VENUS 2)
5000 
MREF error (Reference voltage error).
IC7002 (LENS drive) or IC6001 (VENUS 2)
6000 
Drive voltage (X) error.
VENUS 2 AD value error, LENS Unit, LENS flex breaks etc.
7000 
Drive voltage (Y) error.
VENUS 2 AD value error, LENS Unit, LENS flex breaks etc.
C.B./Zoom
0100
HP Low detect error (C.B. encoder (full retract) always Low detect).
FP9001-(30) signal line or IC6001 (VENUS 2)
0200
HP High detect error (C.B. encoder (full retract) always High detect).
FP9001-(30) signal line or IC6001 (VENUS 2)
0300
ENC1 detect error (C.B. motor encoder detect error).
FP9001-(5) signal line or IC6001 (VENUS 2)
0400
ENC2 detect error (C.B. motor encoder detect error).
FP9001-(3) signal line or IC6001 (VENUS 2)
Zoom
0010
HP Low detect error (Zoom encoder always Low detect error).
FP9001-(3,5) signal line or IC6001 (VENUS 2)
0020
HP High detect error (Zoom encoder always High detect error).
FP9001-(3,5) signal line or IC6001 (VENUS 2)
0030
ENC1 detect error (Zoom encoder detect error).
FP9001-(5) signal line or IC6001 (VENUS 2)
0040
ENC2 detect error (Zoom encoder detect error).
FP9001-(3) signal line or IC6001 (VENUS 2)
Focus
0001
HP Low detect error (Focus encoder always Low detect error).
FP9001-(30) signal line or IC6001 (VENUS 2)
0002
HP High detect error (Focus encoder always High detect error).
FP9001-(30) signal line or IC6001 (VENUS 2)
0003
MR A aspect output error
0004
MR B aspect output error
Lens
1801
0000
Power ON time out error.
Lens drive system
1802
0000
Power OFF time out error.
Lens drive system
Adj.History
OIS
1900
2000
OIS adj. Yaw direction amplitude error (small)
3000
OIS adj. Pit direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pit direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pit direction off set error
A000
OIS adj. Yaw direction gain  error
B000
OIS adj. Pit direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pit direction position sensor error
E000
OIS adj. other error
HARD
VENUS A/D
Flash
2800
0000
Flash charging error.
IC6001-(13) signal line or Flash charging circuit
FLASH ROM
(EEPROM 
Area)
FLASH ROM
(EEPROM 
Area)
2B00
0001
EEPROM read error
IC6002 (FLASH ROM)
0002
EEPROM write error
IC6002 (FLASH ROM)
SYSTEM
RTC
2C00
0001
SYSTEM IC initialize failure error
Communication between IC6001 (VENUS 2) and IC9101 (SYSTEM)
18
• 5. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized by the unit only.
SOFT
CPU
Reset
3000
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
3100
0001
Card logic error
SD card data line or IC6001 (VENUS 2)
0002
Card physical error
SD card data line or IC6001 (VENUS 2)
0004
Write error
SD card data line or IC6001 (VENUS 2)
0005
Format error
SD card data line or IC6001 (VENUS 2)
CPU, 
ASIC hard
Stop
3800
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 2)
0002
Camera task invalid code error.
IC6001 (VENUS 2)
0100
File time out error in recording motion image
IC6001 (VENUS 2)
0200
File data send error in recording motion image
IC6001 (VENUS 2)
Monitor
1000
AF frame movement check time out.
IC6001 (VENUS 2)
Operation
Power on
3B00
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C00
0000
I do not complete zoom lens processing
Zoom lens
3500
0000
I jumped into dummy processing
(0-7bit : command, 8-15bit : Status)
3502
0000
Though record preprocessing is necessary, it is not called.
3503
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
19
6.2.
Confirmation of Firmware Version
The Firmware version can be confirmed by ordering the following steps:.
• Step 1. The temporary cancellation of factory setting:
Set the mode dial to “[ P ]”.  
While keep pressing [ Optical Image Stabilizer ] and “[ UP ] of Cross key” simultaneously. turn the power on with inserting the SD
memory card which has a few photo data.
• Step 2. Confirm the version:
Set the mode dial to “[ Playback ]” and then press [ DISPLAY ] to switch to LCD with indication. (Fig. A)
Press [ Optical Image Stabilizer ] and “[ DOWN ] of Cross key” simultaneously. (No need to keep pressing.)
(The version information is displayed on the LCD with light blue colour letters.) (Fig. B) 
CAUTION:
The version information does not display if the LCD has switched to LCD with indication already.
In this case, press [ DISPLAY ] to switch to LCD with indication.
<Point>
• The firmware version and EEPROM version can be confirmed with the information (1).
• The information (2), (3) are just reference.
20
7 Service Fixture & Tools
7.1.
Service Fixture and Tools
The following Service Fixture and tools are used for checking and servicing this unit.
7.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG-PAVC” web-site in “TSN
system”, together with Maintenance software.
Page of 59
Display

Click on the first or last page to see other DMC-LX1PP / DMC-LX1EB / DMC-LX1EG / DMC-LX1EGM / DMC-LX1GC / DMC-LX1GD / DMC-LX1GK / DMC-LX1GN / DMC-LX1GT / DMC-LX1SG service manuals if exist.