Panasonic DMC-FT1EB / DMC-FT1EE / DMC-FT1EF / DMC-FT1EG / DMC-FT1EP / DMC-FT1GC / DMC-FT1GJ / DMC-FT1GN / DMC-FT1SG / DMC-TS1P / DMC-TS1PC / DMC-TS1PU / DMC-TS1GH / DMC-TS1GK / DMC-TS1GT Service Manual ▷ View online
33
34
8 Service Fixture & Tools
8.1.
Service Fixture and Tools
The following Service Fixture and tools are used for checking and servicing this unit.
35
8.2.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.
8.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
8.3.1.
Extension Cable Connections
No.
Parts No.
Connection
Form
1
RFKZ0416
FP9003 (Main P.C.B.) - Lens with CCD unit (CCD section)
41PIN 0.3 FFC
2
RFKZ0416
FP9002 (Main P.C.B.) - Lens with CCD unit (Lens section)
41PIN 0.3 FFC
3
VFK1364
FP9001 (Main P.C.B.) - FT6301 (Top P.C.B.)
14PIN 0.5 FFC
4
VFK1174
FP9004 (Main P.C.B.) - Rear Operation P.C.B.
16PIN 0.5 FFC
36
Note when repairing PCB
In this unit, battery door lock detection switch is mounted on Main PCB so as to secure the waterproof performance.
Be careful of following points.
(1)Before removing Main PCB, be sure to cancel Initial setting.
Be careful of following points.
(1)Before removing Main PCB, be sure to cancel Initial setting.
If the unit is turned on while Battery Door is not locked correctly, the following warning display as right figure appears on LCD,
and
and
this unit cannot be operated.
When Main PCB was removed, this battery door lock detection switch becomes to status of "Battery Door: OPEN".
Thus battery door lock detection switch does not operate correctly.
And even if the unit is turned on, this unit cannot be operated.
When initial setting was cancelled, battery door lock detection switch is ignored and the unit always be in status of
"Battery Door: CLOSE" and the unit can be operated even if Main PCB is removed.
Thus battery door lock detection switch does not operate correctly.
And even if the unit is turned on, this unit cannot be operated.
When initial setting was cancelled, battery door lock detection switch is ignored and the unit always be in status of
"Battery Door: CLOSE" and the unit can be operated even if Main PCB is removed.
CAUTION-1. (When servicing FLASH PCB)
1. Be sure to discharge the capacitor on FLASH PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH PCB.