DOWNLOAD Panasonic DMC-FT1EB / DMC-FT1EE / DMC-FT1EF / DMC-FT1EG / DMC-FT1EP / DMC-FT1GC / DMC-FT1GJ / DMC-FT1GN / DMC-FT1SG / DMC-TS1P / DMC-TS1PC / DMC-TS1PU / DMC-TS1GH / DMC-TS1GK / DMC-TS1GT Service Manual ↓ Size: 5.37 MB | Pages: 65 in PDF or view online for FREE

Model
DMC-FT1EB DMC-FT1EE DMC-FT1EF DMC-FT1EG DMC-FT1EP DMC-FT1GC DMC-FT1GJ DMC-FT1GN DMC-FT1SG DMC-TS1P DMC-TS1PC DMC-TS1PU DMC-TS1GH DMC-TS1GK DMC-TS1GT
Pages
65
Size
5.37 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / DIGITAL CAMERA
File
dmc-ft1eb-dmc-ft1ee-dmc-ft1ef-dmc-ft1eg-dmc-ft1ep-.pdf
Date

Panasonic DMC-FT1EB / DMC-FT1EE / DMC-FT1EF / DMC-FT1EG / DMC-FT1EP / DMC-FT1GC / DMC-FT1GJ / DMC-FT1GN / DMC-FT1SG / DMC-TS1P / DMC-TS1PC / DMC-TS1PU / DMC-TS1GH / DMC-TS1GK / DMC-TS1GT Service Manual ▷ View online

21
5 Location of Controls and Components
22
23
6 Service Mode
6.1.
Error Code Memory Function
1. General description
This unit is equipped with history of error code memory function, and can be memorized 16 error codes in sequence from the                   
latest. When the error is occurred more than 16, the oldest error is overwritten in sequence.
The error code is not memorized when the power supply is shut down forcibly (i.e.,when the unit is powered on by the battery,
the battery is pulled out) The error code is memorized to FLASH ROM when the unit has just before powered off.
2. How to display
The error code can be displayed by ordering the following procedure:
• Preparation:
1. Attach the Battery or AC Adaptor with a DC coupler to the unit.
NOTE: 
*Since this unit has built-in memory, it can be performed without inserting SD memory card.
*Set the mode dial other than "CLIPBOARD (memo)" mode (such as normal picture / iA / Sports / Snow / SCN)
      to display the error code.
• Step 1. The temporary cancellation of "INITIAL SETTINGS":
While keep pressing "UP of Cursor button" and DISPLAY button simultaneously, turn the Power on.
• Step 2. Execute the error code display mode:
Press the "LEFT of Cursor button", MENU/SET button and DISPLAY button simultaneously.
The display is changed as shown below when the above buttons are pressed simultaneously.
Normal display 
→ Error code display → Operation history display → Normal display → .....
24
3. Error Code List
The error code consists of 8 bits data and it shows the following information.
Attribute
Main item
Sub item
Error code
Contents (Upper)
Error Indication
High 4bits Low 4 bits
Check point (Lower)
Detecting
device
Part/Circuit
LENS
Lens drive OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect
error in OIS unit.
OIS X
LENSu NG
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect
error in OIS unit.
OIS Y
OIS Unit
3000
GYRO (X) error. Gyro (IC7101) detect error on Main
P.C.B..
JYRO X
JYRO NG
IC7101 (Gyro element) or IC6001 (VENUS HD)
4000
GYRO (Y) error. Gyro (IC7101) detect error on Main
P.C.B..
JYRO Y
IC7101 (Gyro element) or IC6001 (VENUS HD)
5000
MREF error (Reference voltage error).
OIS REF
LENSSd/DSP 
NG
IC9101 (LENS drive) or IC6001 (VENUS HD)
6000
Drive voltage (X) error.
OISX REF
LENSu/LENS 
FPC
LENS Unit, LENS flex breaks, IC6001(VENUS HD)
AD value error, etc.
7000
Drive voltage (Y) error.
OISY REF
LENS Unit, LENS flex breaks, IC6001(VENUS HD)
AD value error, etc.
Zoom
0?10
Collapsible barrel Low detect error
(Collapsible barrel encoder always detects Low.)
ZOOM L
ZOOMm/
LENSu
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
0?20
Collapsible barrel High detect error
(Collapsible barrel encoder always detects High.)
ZOOM H
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
0?60
The zoom position jump is detected due to the
impact (i.e. drop.) to the camera occurs.
(No indication) (No indication)
Lens unit
Focus
0?01
HP High detect error
(Focus encoder always detects High, and not
becomes Low)
FOCUS L
LENS FPC/
DSP
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
0?02
HP Low detect error
(Focus encoder always detects Low, and not
becomes High)
FOCUS H
Mechanical lock, FP9005-(26) signal line or IC6001
(VENUS HD)
Lens
18*1
0000
Power ON time out error.
LENS DRV
LENSu
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
Adj.History OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
OIS ADJ
OIS ADJ
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pitch direction position sensor error
E000
OIS adj. other error
HARD
VENUS A/
D
Flash
28*0
0000
Flash charging error.
STRB CHG
STRB PCB/
FPC
IC6001-(AA17) signal line or Flash charging circuit
Page of 65
Display

Click on the first or last page to see other DMC-FT1EB / DMC-FT1EE / DMC-FT1EF / DMC-FT1EG / DMC-FT1EP / DMC-FT1GC / DMC-FT1GJ / DMC-FT1GN / DMC-FT1SG / DMC-TS1P / DMC-TS1PC / DMC-TS1PU / DMC-TS1GH / DMC-TS1GK / DMC-TS1GT service manuals if exist.