29
7.1.2.
Periodical maintenance (Packing replacement) flow
• The integrity of the waterproof packings may decrease about 1 year, with use and age.
(We recommend end-users to replace the waterproof packing at least once each year described in the operating instructions.)
• Please use waterproof packing kit (Part No.: VUMG1863). (7 types, 8 packings in total are included)
• Do not touch the waterproof packings directly by the hand.
• Do not perform cleaning of waterproof packings by the solvent of alcohol etc. or by blowing air.
• Take care not to put any foreign objects (garbage and dust).
• As for the air-leak test, refer to "7.2. Air-leak Test".
• Do not touch the waterproof packings directly by the hand.
• Do not perform cleaning of waterproof packings by the solvent of alcohol etc. or by blowing air.
• Take care not to put any foreign objects (garbage and dust).
• As for the air-leak test, refer to "7.2. Air-leak Test".
30
Replacing the waterproof packing
• The location of waterproof packing are shown at right. (7 types, 8 packings in total)
• Waterproof packings are supplied as Waterproof packing kit (Part No.: VUMG1863).
• Waterproof packings are supplied as Waterproof packing kit (Part No.: VUMG1863).
<Note for replacement>
• Do not touch the waterproof packings directly by the hand.
• Do not perform cleaning of waterproof packings by the solvent of alcohol etc. or by blowing air.
• Take care not to put any foreign objects (garbage and dust).
• Use the silicon chips (Prt No.: RFKZ0478) when replacing the Case O-ring.
• When replacing the mode dial O-ring, wipe the grease attached to the product first, then apply the grease (Part No.: RFKZ0463).
• Do not perform cleaning of waterproof packings by the solvent of alcohol etc. or by blowing air.
• Take care not to put any foreign objects (garbage and dust).
• Use the silicon chips (Prt No.: RFKZ0478) when replacing the Case O-ring.
• When replacing the mode dial O-ring, wipe the grease attached to the product first, then apply the grease (Part No.: RFKZ0463).
31
7.2.
Air-leak Test
32
7.3.
Air-leak Test (Inspection)
Click on the first or last page to see other DMC-FT1EB / DMC-FT1EE / DMC-FT1EF / DMC-FT1EG / DMC-FT1EP / DMC-FT1GC / DMC-FT1GJ / DMC-FT1GN / DMC-FT1SG / DMC-TS1P / DMC-TS1PC / DMC-TS1PU / DMC-TS1GH / DMC-TS1GK / DMC-TS1GT service manuals if exist.