Panasonic WH-SDC09F3E8 / WH-SDC12F9E8 / WH-SDC14F9E8 / WH-SDC16F9E8 / WH-UD09FE8 / WH-UD12FE8 / WH-UD14FE8 / WH-UD16FE8 Service Manual ▷ View online
9
Item
Unit
Indoor Unit
Expansion Vessel
Volume
I
10
MWP
bar
3
Capacity of Integrated Electric Heater
kW
3.00
Note:
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet
temperature of 12°C and water outlet temperature of 7°C.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
10
2.2 WH-SDC12F9E8
WH-UD12FE8
Item
Unit
Outdoor Unit
Performance Test Condition
EN 14511
Cooling Capacity
Condition
(Ambient/Water)
A35W7
kW
10.00
BTU/h
34100
kcal/h
8600
Cooling EER
W/W
2.85
kcal/hW
2.45
Heating Capacity
Condition
(Ambient/Water)
A7W35
A2W35
kW
12.00
11.40
BTU/h
41000
38900
kcal/h
10320
9800
Heating COP
W/W
4.74
3.44
kcal/hW
4.08
2.96
Noise Level
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
dB (A)
Cooling: 50
Heating: 50
—
Power Level dB
Cooling: 68
Heating: 67
—
Air Flow
m
3
/min (ft
3
/min)
Cooling: 93.3 (3290)
Heating: 80.0 (2830)
Heating: 80.0 (2830)
Refrigeration Control Device
Expansion Valve
Refrigeration Oil
cm
3
FV50S (1200)
Refrigerant (R410A)
kg (oz)
2.55 (90.0)
Dimension
Height
mm (inch)
1340 (52-3/4)
Width
mm (inch)
900 (35-7/16)
Depth
mm (inch)
320 (12-19/32)
Net Weight
kg (lbs)
108 (238)
Pipe Diameter
Liquid
mm (inch)
9.52 (3/8)
Gas
mm (inch)
15.88 (5/8)
Standard Length
m (ft)
7 (23.0)
Pipe Length Range
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height Difference
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
50 (0.5)
Refrigeration Charge Less
m (ft)
10 (32.8)
Compressor
Type
Hermetic Motor / Rotary
Motor Type
Brushless (4-poles)
Rated Output
kW
4.30
Fan
Type
Propeller Fan
Material
PP
Motor Type
DC (8-poles)
Input Power
W
—
Output Power
W
60
Fan Speed
rpm
Cooling: 600 (Top), 640 (Bottom)
Heating: 510 (Top), 550 (Bottom)
Heating: 510 (Top), 550 (Bottom)
Heat Exchanger
Fin material
Aluminium (Pre Coat)
Fin Type
Corrugated Fin
Row × Stage × FPI
2 × 51 × 18
Size (W × H × L)
mm
903.7 × 1295.4 × 38.1
11
Item
Unit
Outdoor Unit
Power Source (Phase, Voltage, Cycle)
ø
Three
V
400
Hz
50
Input Power
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
kW
Cooling: 3.51
Heating: 2.53
Heating: 3.31
Maximum Input Power For Heatpump System
kW
5.85
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
3Ø / 8.8 / 5.85k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
3Ø / 13.0 / 9.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W)
— / — / —
Starting Current
A
5.3
Running Current
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
A
Cooling: 5.3
Heating: 3.8
Heating: 5.0
Maximum Current For Heatpump System
A
8.8
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Power factor means total figure of compressor and
outdoor fan motor.
%
Cooling: 96
Heating: 96
Heating: 96
Power Cord
Number of core
—
Length
m (ft)
—
Thermostat
Electronic Control
Protection Device
Electronic Control
Item
Unit
Indoor Unit
Performance Test Condition
EN 14511
Operation Range
Outdoor Ambient
°C
Cooling: 16 ~ 43
Heating: -20 ~ 35
Water Outlet
°C
Cooling: 5 ~ 20
Heating: 25 ~ 55
Internal Pressure Differential
kPa
Cooling: 23.1
Heating: 33.0
Heating: 33.0
Noise Level
Condition
(Ambient/Water)
A35W7
A7W35
A2W35
dB (A)
Cooling: 33
Cooling: 33
—
Power Level dB
Cooling: 46
Cooling: 46
—
Dimension
Height
mm (inch)
892 (35-1/8)
Width
mm (inch)
502 (19-3/4)
Depth
mm (inch)
353 (13-29/32)
Net Weight
kg (lbs)
46 (101)
Refrigerant Pipe Diameter
Liquid
mm (inch)
9.52 (3/8)
Gas
mm (inch)
15.88 (5/8)
Water Pipe Diameter
Inlet
mm (inch)
28 (1-3/32)
Outlet
mm (inch)
28 (1-3/32)
Water Drain Hose Inner Diameter
mm (inch)
15 (19/32)
Pump
Motor Type
DC Motor
No. of Speed
7 (Software Selection)
Input Power
W
60
Hot Water Coil
Type
Brazed Plate
No. of Plates
36
Size (W × H × L)
mm
65 × 120 × 376
Water Flow Rate
l/min (m
3
/h)
Cooling: 28.7 (1.7)
Heating: 34.4 (2.1)
Heating: 34.4 (2.1)
Pressure Relief Valve Water Circuit
kPa
Open: 300, Close: 265 and below
Flow Switch
Magnetic Lead Switch
Protection Device
A
Residual Current Circuit Breaker (25)
12
Item
Unit
Indoor Unit
Expansion Vessel
Volume
I
10
MWP
bar
3
Capacity of Integrated Electric Heater
kW
9.00
Note:
Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet
temperature of 12°C and water outlet temperature of 7°C.
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Click on the first or last page to see other WH-SDC09F3E8 / WH-SDC12F9E8 / WH-SDC14F9E8 / WH-SDC16F9E8 / WH-UD09FE8 / WH-UD12FE8 / WH-UD14FE8 / WH-UD16FE8 service manuals if exist.