CAUTION 
WARNING 
 
19. The unit is only for use in a closed portable water system. Utilization in an open water circuit or non-portable water circuit, may lead to 
      excessive corrosion of the water piping and risk of incubating bacteria colonies, particularly Legionella, in water. 
 
20. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 
21. Do not dismantle refrigerant piping using pipe wrench. It might deform the piping and cause the unit to malfunction. 
22. Select a location where in case of water leakage, the leakage will not cause damage to other properties. 
23. Do not locally purchase electrical parts of the product for the purpose of installation, service, maintenance and etc. They might cause 
      electrical shock or fire. 
24. Do not branch the power from terminal block to heater tape. Overloaded terminal block will cause electrical shock or fire. 
25. Installation or servicing work. It may need two people to carry out the installation or servicing work. 
26. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other 
      electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire. 
27. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may 
      break and cause refrigerant gas leakage. 
 
 
1.   Do not install the air-to-water heatpump indoor unit and outdoor unit at place where leakage of flammable gas may occur. In case  
      gas leaks and accumulates at surrounding of the unit, it may cause fire. 
2.   Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the 
      furniture. 
3.   It may need two persons to carry out the installation work. The weight of indoor/outdoor unit might cause injury if carried by one person. 
4.   Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 
5.   Select an installation location which is easy for maintenance. 
6.   Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F - 70°F (30°C - 40°C) higher. Please use a 
      high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). 
      Pb free solder will tend to splash when heated too high (about 1100°F/600°C). 
7.   Power supply connection to indoor unit. 
      1. Power supply point should be in easily accessible place for power disconnection in case of emergency. 
      2. Must follow local national wiring standard, regulation and this installation instruction. 
      3. Strongly recommended to make permanent connection to a circuit breaker. 
               - Power Supply 1: Use approved 20A 4-poles circuit breaker with a minimum contact gap of 3.0 mm. 
               - Power Supply 2: Use approved 15/16A 2-poles circuit breaker with a minimum contact gap of 3.0 mm. 
                                              (Only applicable for WH-SDC09F3E8) 
or 
                                             Use approved 20A 4-poles circuit breaker with a minimum contact gap of 3.0 mm. 
                                              (Only applicable for WH-SDC12F9E8) 
      WH-SDC14F9E8 WH-UD14FE8  WH-SDC16F9E8 WH-UD16FE8 only 
8.   Power supply connection to indoor unit. 
      1. Power supply point should be in easily accessible place for power disconnection in case of emergency. 
      2. Must follow local national wiring standard, regulation and this installation instruction. 
      3. Strongly recommended to make permanent connection to a circuit breaker. 
               - Power Supply 1: Use approved 20A 4-poles circuit breaker with a minimum contact gap of 3.0 mm. 
               - Power Supply 2: Use approved 20A 4-poles circuit breaker with a minimum contact gap of 3.0 mm. 
9.   Do not release refrigerant during piping work for installation, servicing, re-installation and during repairing a refrigeration parts. Take 
      care of the liquid refrigerant, it may cause frostbite. 
10.   Do not install this appliance in a laundry room or other high humidity location. This condition will cause rust and damage to the unit. 
11. Make sure the insulation of power supply cord does not contact to hot part (i.e. refrigerant piping, water piping) to prevent from 
      insulation failure (melt). 
12. Do not sit, step or place anything on the unit, you may fall down accidentally. 
13. Do not touch the sharp aluminum fins or edges of metal parts. 
      If you are required to handle sharp parts during installation or servicing, please wear hand glove. 
      Sharp parts may cause injury. 
CAUTION 
 
14. After installation, check the water leakage condition in connection area during test run. If leakage occur, it will cause damage to other 
      properties. 
15. The unit described in this manual is designed for use in a closed water system only. Utilization in an open water circuit may lead to 
      excessive corrosion of the water piping. 
2. Specifications 
2.1 WH-SDC09F3E8 
WH-UD09FE8 
 
Item 
Unit 
Outdoor Unit 
Performance Test Condition 
EN 14511 
Cooling Capacity 
Condition 
(Ambient/Water) 
A35W7 
kW 
7.00 
BTU/h 
23900 
kcal/h 
6020 
Cooling EER 
W/W 
3.17 
kcal/hW 
2.72 
Heating Capacity 
Condition 
(Ambient/Water) 
A7W35 
A2W35 
kW 
9.00 
9.00 
BTU/h 
30700 
30700 
kcal/h 
7740 
7740 
Heating COP 
W/W 
4.84 
3.59 
kcal/hW 
4.16 
3.08 
Noise Level 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
dB (A) 
Cooling: 49 
Heating: 49 
— 
Power Level dB 
Cooling: 67 
Heating: 66 
— 
Air Flow 
m
3
/min (ft
3
/min) 
Cooling: 89.5 (3160) 
Heating: 76.8 (2710) 
Refrigeration Control Device 
 
Expansion Valve 
Refrigeration Oil 
cm
3
 
FV50S (1200) 
Refrigerant (R410A) 
kg (oz) 
2.55 (90.0) 
Dimension 
Height 
mm (inch) 
1340 (52-3/4) 
Width 
mm (inch) 
900 (35-7/16) 
Depth 
mm (inch) 
320 (12-19/32) 
Net Weight 
kg (lbs) 
108 (238) 
Pipe Diameter 
Liquid 
mm (inch) 
9.52 (3/8) 
Gas 
mm (inch) 
15.88 (5/8) 
Standard Length 
m (ft) 
7 (23.0) 
Pipe Length Range 
m (ft) 
3 (9.8) ~ 30 (98.4) 
I/D & O/D Height Difference 
m (ft) 
20 (65.6) 
Additional Gas Amount 
g/m (oz/ft) 
50 (0.5) 
Refrigeration Charge Less 
m (ft) 
10 (32.8) 
Compressor 
Type 
 
Hermetic Motor / Rotary 
Motor Type 
 
Brushless (4-poles) 
Rated Output 
kW 
4.30 
Fan 
Type 
 
Propeller Fan 
Material 
 
PP 
Motor Type 
 
DC (8-poles) 
Input Power 
— 
Output Power 
60 
Fan Speed 
rpm 
Cooling: 550 (Top), 590 (Bottom) 
Heating: 490 (Top), 530 (Bottom) 
Heat Exchanger 
Fin material 
 
Aluminium (Pre Coat) 
Fin Type 
 
Corrugated Fin 
Row × Stage × FPI 
 
2 × 51 × 18 
Size (W × H × L) 
mm 
903.7 × 1295.4 × 38.1 
 
Item 
Unit 
Outdoor Unit 
Power Source (Phase, Voltage, Cycle) 
ø 
Three 
400 
Hz 
50 
Input Power 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
kW 
Cooling: 2.21 
Heating: 1.86 
Heating: 2.51 
Maximum Input Power For Heatpump System 
kW 
4.94 
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
3Ø / 11.8 / 7.94k 
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
1Ø / 13.0 / 3.00k 
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
— / — / — 
Starting Current 
3.4 
Running Current 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
Cooling: 3.4 
Heating: 2.8 
Heating: 3.8 
Maximum Current For Heatpump System 
7.5 
Power Factor 
Power factor means total figure of compressor and 
outdoor fan motor. 
Cooling: 95 
Heating: 96 
Power Cord 
Number of core 
 
— 
Length 
m (ft) 
— 
Thermostat 
 
Electronic Control 
Protection Device 
 
Electronic Control 
 
Item 
Unit 
Indoor Unit 
Performance Test Condition 
EN 14511 
Operation Range 
Outdoor Ambient 
°C 
Cooling: 16 ~ 43 
Heating: -20 ~ 35 
Water Outlet 
°C 
Cooling: 5 ~ 20 
Heating: 25 ~ 55 
Internal Pressure Differential 
kPa 
Cooling: 11.6 
Heating: 18.7 
Noise Level 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
dB (A) 
Cooling: 33 
Cooling: 33 
— 
Power Level dB 
Cooling: 46 
Cooling: 46 
— 
Dimension 
Height 
mm (inch) 
892 (35-1/8) 
Width 
mm (inch) 
502 (19-3/4) 
Depth 
mm (inch) 
353 (13-29/32) 
Net Weight 
kg (lbs) 
45 (99) 
Refrigerant Pipe Diameter 
Liquid 
mm (inch) 
9.52 (3/8) 
Gas 
mm (inch) 
15.88 (5/8) 
Water Pipe Diameter 
Inlet 
mm (inch) 
28 (1-3/32) 
Outlet 
mm (inch) 
28 (1-3/32) 
Water Drain Hose Inner Diameter 
mm (inch) 
15 (19/32) 
Pump 
Motor Type 
 
DC Motor 
No. of Speed 
 
7 (Software Selection) 
Input Power 
42 
Hot Water Coil 
Type 
 
Brazed Plate 
No. of Plates 
 
36 
Size (W × H × L) 
mm 
65 × 120 × 376 
Water Flow Rate 
l/min (m
3
/h) 
Cooling: 20.1 (1.2) 
Heating: 25.8 (1.5) 
Pressure Relief Valve Water Circuit 
kPa 
Open: 300, Close: 265 and below 
Flow Switch 
 
Magnetic Lead Switch 
Protection Device 
Residual Current Circuit Breaker (25) 
 
 
 
Page of 127
Display