DOWNLOAD Panasonic WH-SDC09F3E8 / WH-SDC12F9E8 / WH-SDC14F9E8 / WH-SDC16F9E8 / WH-UD09FE8 / WH-UD12FE8 / WH-UD14FE8 / WH-UD16FE8 Service Manual ↓ Size: 8.66 MB | Pages: 127 in PDF or view online for FREE

Model
WH-SDC09F3E8 WH-SDC12F9E8 WH-SDC14F9E8 WH-SDC16F9E8 WH-UD09FE8 WH-UD12FE8 WH-UD14FE8 WH-UD16FE8
Pages
127
Size
8.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Air Conditioner / AIR-TO-WATER HEATPUMP
File
wh-sdc09f3e8-wh-sdc12f9e8-wh-sdc14f9e8-wh-sdc16f9e.pdf
Date

Panasonic WH-SDC09F3E8 / WH-SDC12F9E8 / WH-SDC14F9E8 / WH-SDC16F9E8 / WH-UD09FE8 / WH-UD12FE8 / WH-UD14FE8 / WH-UD16FE8 Service Manual ▷ View online

17 
Item 
Unit 
Outdoor Unit 
Power Source (Phase, Voltage, Cycle) 
ø 
Three 
400 
Hz 
50 
Input Power 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
kW 
Cooling: 4.76 
Heating: 3.74 
Heating: 3.96 
Maximum Input Power For Heatpump System 
kW 
6.59 
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
3Ø / 9.9 / 6.59k 
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
3Ø / 13.0 / 9.00k 
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 
— / — / — 
Starting Current 
7.1 
Running Current 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
Cooling: 7.1 
Heating: 5.7 
Heating: 6.0 
Maximum Current For Heatpump System 
9.9 
Power Factor 
Power factor means total figure of compressor and 
outdoor fan motor. 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
Cooling: 97 
Heating: 95 
Heating: 96 
Power Cord 
Number of core 
 
— 
Length 
m (ft) 
— 
Thermostat 
 
Electronic Control 
Protection Device 
 
Electronic Control 
 
Item 
Unit 
Indoor Unit 
Performance Test Condition 
EN 14511 
Operation Range 
Outdoor Ambient 
°C 
Cooling: 16 ~ 43 
Heating: -20 ~ 35 
Water Outlet 
°C 
Cooling: 5 ~ 20 
Heating: 25 ~ 55 
Internal Pressure Differential 
kPa 
Cooling: 35.2 
Heating: 58.0 
Noise Level 
Condition 
(Ambient/Water) 
A35W7 
A7W35 
A2W35 
dB (A) 
Cooling: 33 
Cooling: 33 
— 
Power Level dB 
Cooling: 46 
Cooling: 46 
— 
Dimension 
Height 
mm (inch) 
892 (35-1/8) 
Width 
mm (inch) 
502 (19-3/4) 
Depth 
mm (inch) 
353 (13-29/32) 
Net Weight 
kg (lbs) 
47 (104) 
Refrigerant Pipe Diameter 
Liquid 
mm (inch) 
9.52 (3/8) 
Gas 
mm (inch) 
15.88 (5/8) 
Water Pipe Diameter 
Inlet 
mm (inch) 
28 (1-3/32) 
Outlet 
mm (inch) 
28 (1-3/32) 
Water Drain Hose Inner Diameter 
mm (inch) 
15 (19/32) 
Pump 
Motor Type 
 
DC Motor 
No. of Speed 
 
7 (Software Selection) 
Input Power 
105 
Hot Water Coil 
Type 
 
Brazed Plate 
No. of Plates 
 
44 
Size (W × H × L) 
mm 
80 × 120 × 376 
Water Flow Rate 
l/min (m
3
/h) 
Cooling: 35.0 (2.1) 
Heating: 45.9 (2.8) 
Pressure Relief Valve Water Circuit 
kPa 
Open: 300, Close: 265 and below 
Flow Switch 
 
Magnetic Lead Switch 
Protection Device 
Residual Current Circuit Breaker (25) 
 
 
 
18 
Item 
Unit 
Indoor Unit 
Expansion Vessel 
Volume 
10 
MWP 
bar 
Capacity of Integrated Electric Heater 
kW 
9.00 
Note: 
  Cooling capacities are based on outdoor air temperature of 35°C Dry Bulb with controlled indoor water inlet 
temperature of 12°C and water outlet temperature of 7°C. 
  Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb 
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C. 
  Specification are subjected to change without prior notice for further improvement. 
 
 
19 
3. Features 
 
  Inverter Technology 
 
- Energy saving 
 
  High Efficiency 
 
  Environment Protection 
 
- Non-ozone depletion substances refrigerant (R410A) 
 
  Long Installation Piping 
 
- Long piping up to 30 meter with height difference 20 meter 
 
- Flexible 4-way piping for outdoor unit 
 
  Easy to use control panel 
 
- Auto mode 
 
- Holiday mode 
 
- Dry concrete function 
 
- Weekly timer setting 
 
 
  A-class energy efficiency pump 
 
- Water pump speed can be set by selection at control panel 
 
  Improved deice cycle 
 
  Protection Feature 
 
- Random auto restart after power failure for safety restart operation 
 
- Gas leakage protection 
 
- Prevent compressor reverse cycle 
 
- Inner protector to protect compressor 
 
  Serviceability Feature 
 
- Breakdown Self Diagnosis function 
 
- System Status Check Buttons for servicing purpose 
 
- System Pumpdown Button for servicing purpose 
 
- Front maintenance design for outdoor unit 
20 
4. Location of Controls and Components 
4.1 Indoor 
Unit 
4.1.1  Location of Control 
 
OPERATION
ACTUAL
HEATER
BOOSTER
QUIET
SETTING
STATUS
SERVICE
AUTO
HEAT
COOL
TANK
HEATER
FORCE
°C
°C
ON
OFF
MON TUE WED THU FRI SAT SUN
hr
hr
kwh
 
Control Panel
 
OFF/ON Button
This button starts or stops the mode operation function of the unit.
Operation LED
     This LED indicates the unit is in operation.
External Thermo Controller Connected Display
     This LCD show the external thermo controller connected display.
Force Heater Request OFF/ON Indicator
     This icon indicates force heater request OFF/ON mode operation.
Backup Heater Enabled/Disabled Indicator
     This icon indicates backup heater enabled/disabled mode operation.
Quiet Mode Indicator
     This icon indicates quiet mode operation.
Tank Mode Indicator
     This icon indicates tank mode operation.
Cool Mode OFF/ON Indicator
     This icon indicates cooling mode OFF/ON operation.
Heat Mode OFF/ON Indicator
     This icon indicates heating mode OFF/ON operation.
Auto Mode OFF/ON Indicator
     This icon indicates auto mode OFF/ON operation.
Solar Display
     This LCD show the solar display.
Caution (Tank Temperature above 60°C) Indicator
     This LCD show the Caution display.
Timer/Clock Setting Display
     This LCD show the weekly schedule timer setting and clock display.
Outdoor Ambient Temperature Display
     This LCD show the outdoor ambient temperature.
Water Outlet Temperature Display
     This LCD show the water outlet temperature.
Backup Heater Actual (OFF/ON) Indicator
     This icon indicates backup heater actual (OFF/ON) operation.
Booster Heater Actual (OFF/ON) Indicator
     This icon indicates booster heater actual (OFF/ON) operation.
System Setting Mode OFF/ON Indicator
     This icon indicates the system setting mode request OFF/ON display.
System Status Check Mode OFF/ON Indicator
     This icon indicates the status check mode request OFF/ON display.
System Service Mode OFF/ON Indicator
     This icon indicates the system service mode request OFF/ON display.
Water pressure gauge
• Do not press or hit the glass cover using hard
and sharp objects. Failure to do so may cause
damage to the unit.
• Ensure that the water pressure is between 0.05
and 0.3 MPa (0.1 MPa = 1 bar).
• In case the water pressure is out of the above
range, consult an authorised dealer.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
15
16
17
18
19
20
1
2
3
4
5
7
8
9
10
11 12
13
14
15
16
17
6
18
19
20
 
Page of 127
Display

Click on the first or last page to see other WH-SDC09F3E8 / WH-SDC12F9E8 / WH-SDC14F9E8 / WH-SDC16F9E8 / WH-UD09FE8 / WH-UD12FE8 / WH-UD14FE8 / WH-UD16FE8 service manuals if exist.