Panasonic CS-YW7MKD / CS-YW9MKD / CS-YW12MKD / CS-YW7MKD-1 / CS-YW9MKD-1 / CS-YW12MKD-1 / CU-YW7MKD / CU-YW9MKD / CU-YW12MKD / CU-YW7MKD-1 / CU-YW9MKD-1 / CU-YW12MKD-1 Service Manual ▷ View online
5
2. Specification
Indoor CS-YW7MKD CS-YW7MKD-1 CS-YW9MKD
CS-YW9MKD-1
CS-YW12MKD CS-YW12MKD-1
Model
Outdoor CU-YW7MKD CU-YW7MKD-1 CU-YW9MKD
CU-YW9MKD-1 CU-YW12MKD CU-YW12MKD-1
Phase, Hz
Single, 50
Single, 50
Single, 50
Power Supply
V 220
220
220
kW 2.10
2.60
3.60
BTU/h 7160
8860
12270
Capacity
kJ/h 1800
2230
3090
Running Current
A
3.40
4.30
5.80
Input Power
W
710
900
1250
W/W 2.95
2.88
2.88
EER
Btu/hW 10.08
9.84
9.81
Power Factor
%
94
95
97
Indoor Noise (H / L )
dB-A
37 / 25
38 / 26
39 / 26
Cooling
Outdoor Noise (H / L)
dB-A
47 / -
48 / -
49 / -
kW 2.10
2.70
3.90
BTU/h 7160
9200
13300
Capacity
kJ/h 1800
2320
3350
Running Current
A
2.80
3.70
5.10
Input Power
W
600
800
1100
W/W 3.50
3.37
3.54
EER
Btu/hW 11.93
11.50
12.09
Power Factor
%
97
98
98
Indoor Noise (H / L )
dB-A
38 / 24
38 / 25
39 / 28
Heating
Outdoor Noise (H / L)
dB-A
48 / -
49 / -
50 / -
Max Current (A) / Max Input Power (W)
4.90 / 940
6.00 / 1.150k
7.90 / 1.520k
Starting Current (A)
19.0
26.0
32.2
Type
Hermetic Motor
Hermetic Motor
Hermetic Motor
Motor Type
Induction (2 poles)
Induction (2 poles)
Induction (2 poles)
Compressor
Output Power
W
600
750
1100
Type
Cross-flow fan
Cross-flow fan
Cross-flow fan
Material
AS
AS
AS
Motor Type
AC (4 poles)
AC (4 poles)
AC (4 poles)
Input Power
W
56.1
56.1
56.1
Output Power
W
20
20
20
Lo rpm
600
650
600
Me rpm
900
920
950
Speed
(Cooling)
Hi rpm
1020
1060
1060
Lo rpm
540
570
680
Me rpm
680
740
840
Indoor Fan
Speed
(Heating)
Hi rpm
920
920
1080
Type Propeller
Propeller
Propeller
Material
PP
PP
PP
Motor Type
PSC (6 poles)
PSC (6 poles)
PSC (6 poles)
Input Power
W
63.36
63.4
74.85
Output Power
W
28
28
28
Hi (Cooling)
rpm
810
810
870
Outdoo
r Fa
n
Speed
Hi (Heating)
rpm
790
790
850
6
Moisture Removal
L/h (Pt/h)
1.3 (2.2)
1.3 (2.2)
2.1 (3.6)
Lo
m
3
/min
(ft
3
/m)
7.03 (248)
7.82 (275)
7.07 (249)
Me
m
3
/min
(ft
3
/m)
10.6 (374)
10.97 (386)
11.16 (393)
Indoor Airflow
(Cooling)
Hi
m
3
/min
(ft
3
/m)
11.9 (420)
12.6 (444)
12.4 (437)
Lo
m
3
/min
(ft
3
/m)
6.08 (214)
6.45 (228)
8.01 (282)
Me
m
3
/min
(ft
3
/m)
7.63 (269)
8.43 (297)
9.91 (349)
Indoor Airflow
(Heating)
Hi
m
3
/min
(ft
3
/m)
10.3 (363)
10.4 (367)
12.7 (448)
Hi (Cooling)
m
3
/min
(ft
3
/m)
26.8 (948)
26.8 (948)
29.0 (1026)
Outdoor
Airflow
Hi (Heating)
m
3
/min
(ft
3
/m)
26.8 (948)
26.8 (948)
29.0 (1026)
Control Device
Capillary Tube
Capillary Tube
Capillary Tube
Refrigeration
Cycle
Refrigerant Type
g (oz)
R410A, 590 (20.8)
R410A, 880 (31.0)
R410A, 930 (32.8)
Height(I/D / O/D) mm (inch)
283 (11-5/32)
530(20-7/8)
283 (11-5/32)
530(20-7/8)
283 (11-5/32)
530(20-7/8)
Width (I/D / O/D) mm (inch)
803 (31-5/8)
650(25-19/32)
803 (31-5/8)
650(25-19/32)
803 (31-5/8)
650(25-19/32)
Dimension
Depth (I/D / O/D) mm (inch)
214 (8-7/16)
230 (9-1/16)
214 (8-7/16)
230 (9-1/16)
214 (8-7/16)
230 (9-1/16)
Weight
Net (I/D / O/D)
kg (lb)
8.0 (18)
22.5 (50)
8.0 (18)
25.5(57)
8.0 (18)
27.5 (61)
Pipe Diameter (Liquid / Gas) mm (inch)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
6.35 (1/4) / 9.52 (3/8)
Standard length
m (ft)
5.0 (16.4)
5.0 (16.4)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 7 (23.0)
3 (9.8) ~ 7 (23.0)
3 (9.8) ~ 10 (32.8)
I/D & O/D Height different
m (ft)
5.0 (16.4)
5.0 (16.4)
5.0 (16.4)
Additional Gas Amount
g/m (oz/ft)
-
-
20 (0.2)
Piping
Length for Additional Gas
m (ft)
-
-
7.0 (23.0)
Inner Diameter
mm
16
16
16
Drain Hose
Length mm
500
500
500
Fin Material
Pre coated
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 16 x 19
2 x16 x 19
2 x16 x 19
Indoor Heat
Exchanger
Size (W x H x L)
mm
610 x 336 x 25.4
610 x 336 x 25.4
610 x 336 x 25.4
Fin Material
Pre coated
Pre coated
Pre coated
Fin Type
Slit Fin
Slit Fin
Slit Fin
Row x Stage x FPI
1 x 24 x 19
1 x 24 x 19
2 x 24 x 18
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
563.9 x 504 x 18.19
563.9 x 504 x 18.19
569.1 x 504 x 36.38
540.5
540.5
Material
P.P.HONEY COMB
P.P.HONEY COMB
P.P.HONEY COMB
Air Filter
Type
One-touch
One-touch
One-touch
Power Supply
Indoor
Indoor
Indoor
Power Supply Cord
A
10
10
10
Thermostat
-
-
-
Protection Device
-
-
-
COOLING HEATING COOLING HEATING COOLING HEATING
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
DRY
BULB
WET
BULB
Maximum
32 23 30 - 32 23 30 - 32 23 30 -
Indoor Operation Range
Minimum
16 11 16 - 16 11 16 - 16 11 16 -
Maximum
43 26 24 18 43 26 24 18 43 26 24 18
Outdoor Operation Range
Minimum
16 11 -5 -6 16 11 -5 -6 16 11 -5 -6
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
2.
Heating capacities are based on indoor temperature of 20°C DRY BULB (68°F DRY BULB), and outdoor air temperature of 7°C DRY BULB
(95°F DRY BULB), 6°C WET BULB (75.2°F WET BULB)
(95°F DRY BULB), 6°C WET BULB (75.2°F WET BULB)
7
3. Features
• Environmental Friendly
o
Using R410A refrigerant.
o
Zero ozone depleting potential
o
Low global warming potential
• Installation Piping Length
o
CS/CU-YW7/9/12MKD(-1) , piping up to 7 meters.
o
CS/CU-YW12MKD(-1) , piping up to 10 meters.
• Easy to use remote control
• 12-hour Timer setting
• Main control function
• 12-hour Timer setting
• Main control function
o
Random auto restart after power failure for safety restart operation
o
Prevent compressor reverse cycle
o
Time delay safety control
o
Anti-Freezing
control
(Cooling)
o
7 minutes time save control (Cooling)
o
Dew formation prevention control (Cooling)
o
Overload
protection
control(Heating)
o
Deice
control
(Heating)
8
4. Location of Controls and Components
4.1 Indoor
Unit
4.2 Outdoor
Unit
4.3 Remote
Control
Click on the first or last page to see other CS-YW7MKD / CS-YW9MKD / CS-YW12MKD / CS-YW7MKD-1 / CS-YW9MKD-1 / CS-YW12MKD-1 / CU-YW7MKD / CU-YW9MKD / CU-YW12MKD / CU-YW7MKD-1 / CU-YW9MKD-1 / CU-YW12MKD-1 service manuals if exist.