8. Wiring Connection Diagram
INDOOR UNIT
14
OUTDOOR UNIT
.
15
9. Installation Instruction
9.1 Select The Best Location
9.1.1 Indoor Unit
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling, fence
or other obstacles.
• Recommended installation height for indoor unit shall be at least
2.5m.
9.1.2 Outdoor Unit
• If an awning is built over the unit to prevent direct sunlight or rain,
be careful that heat radiation from the condenser is not obstructed.
• There should not be any animal or plant which could be affected by
hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling, fence or
other obstacles.
• Do not place any obstacles which may cause a short circuit of the
discharged air.
• If piping length is over the rated length, additional refrigerant should
be added as shown in the table below:
Example: For YW12MKD
If the unit is installed at a 10m distance, the quantity of additional refrigerant
should be 50 g.…… (10-7) m x 20g/m = 60 g
Piping size
Model
Gas
Liqui
d
Rate
d
Leng
th
(m)
Max
Elevati
on (m)
Min
Piping
Length
(m)
Max
Piping
Length
(m)
Addition
al
Refriger
ant
(g/m)
Piping
Length
for add.
Gas (m)
CS/CU-YW7MKD
3/8” 1/4"
5.0 5.0
3
7
-
-
CS/CU-YW9MKD
3/8” 1/4”
5.0 5.0
3
7
-
-
CS/CU-YW12MKD
3/8” 1/4”
5.0 5.0 3 10 20 7.0
CS/CU-YW7MKD-1
3/8” 1/4"
5.0 5.0
3
7
-
-
CS/CU-YW9MKD-1
3/8” 1/4”
5.0 5.0
3
7
-
-
CS/CU-YW12MKD-1
3/8” 1/4”
5.0 5.0 3 10 20 7.0
9.1.3 Indoor/Outdoor Unit
*This illustration is for explanation
purposes only.
The indoor unit will actually face a
different way.
purposes only.
The indoor unit will actually face a
different way.
16
Wall
Indoor
Outdoor
15 mm
Sleeve for
tube ass’y
tube ass’y
Approx. 5 - 7 mm
Bushing for tube ass’y
Putty or caulking compound
Ø 70 through hole
9.2 Indoor
Unit
9.2.1 How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent if from the vibration.
The centre of installation plate should be at more
than 450 mm at right and left of the wall.
The distance from installation plate edge to
ceiling should more than 120mm.
From installation plate left edge to unit’s left side
is 170 mm.
From installation plate right edge to unit’s right
side is 160 mm.
The centre of installation plate should be at more
than 450 mm at right and left of the wall.
The distance from installation plate edge to
ceiling should more than 120mm.
From installation plate left edge to unit’s left side
is 170 mm.
From installation plate right edge to unit’s right
side is 160 mm.
○
B
: For left side piping, piping connection for liquid should be about 105 mm from this line.
:
For left side piping, piping connection for gas should be about 154 mm from this line.
1 Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider
using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with
the thread and using a level gauge.
the thread and using a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
z Put measuring tape at position as shown in the diagram above. The hole centre is
obtained by measuring the distance namely 178.5 mm and 161 mm for left and right
hole respectively.
hole respectively.
z Drill the piping plate hole at either the right or left and the hole should be slightly slanted
to the outdoor side.
9.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the busing to the sleeve.
3
Cut the sleeve until it extrudes about 15mm from the wall
4
Finish by sealing the sleeve with putty or caulking compound at the final
stage.
stage.
Caution
When the wall is hollow, please be sure to use the sleeve for tube
ass’y to prevent dangers caused by mice biting the connecting
cable.
ass’y to prevent dangers caused by mice biting the connecting
cable.