8. Wiring Connection Diagram 
INDOOR UNIT 
 
 
 
 
 
 
 
14 
 
OUTDOOR UNIT 
 
 

 
 
         
 
15 
9. Installation Instruction 
9.1  Select The Best Location  
9.1.1 Indoor Unit 
•  There should not be any heat source or steam near the unit.  
•  There should not be any obstacles blocking the air circulation. 
•  A place where air circulation in the room is good. 
•  A place where drainage can be easily done. 
•  A place where noise prevention is taken into consideration. 
•  Do not install the unit near the door way.  
•  Ensure the spaces indicated by arrows from the wall, ceiling, fence 
or other obstacles. 
•  Recommended installation height for indoor unit shall be at least 
2.5m. 
9.1.2 Outdoor Unit 
•  If an awning is built over the unit to prevent direct sunlight or rain, 
be careful that heat radiation from the condenser is not obstructed. 
•  There should not be any animal or plant which could be affected by 
hot air discharged. 
•  Keep the spaces indicated by arrows from wall, ceiling, fence or 
other obstacles. 
•  Do not place any obstacles which may cause a short circuit of the 
discharged air. 
•  If piping length is over the rated length, additional refrigerant should 
be added as shown in the table below: 
 
 
 
Example: For YW12MKD 
If the unit is installed at a 10m distance, the quantity of additional refrigerant  
should be 50 g.…… (10-7) m x 20g/m = 60 g 
 
 
 
Piping size
Model 
Gas 
Liqui
Rate
Leng
th 
(m) 
Max 
Elevati
on (m) 
Min 
Piping 
Length 
(m)
Max 
Piping 
Length 
(m) 
Addition
al 
Refriger
ant 
(g/m)
Piping 
Length 
for add. 
Gas (m)
CS/CU-YW7MKD 
3/8” 1/4"
5.0  5.0 
CS/CU-YW9MKD 
3/8” 1/4”
5.0  5.0 
CS/CU-YW12MKD 
3/8” 1/4”
5.0  5.0 3  10  20  7.0 
CS/CU-YW7MKD-1 
3/8” 1/4"
5.0  5.0 
CS/CU-YW9MKD-1 
3/8” 1/4”
5.0  5.0 
CS/CU-YW12MKD-1 
3/8” 1/4”
5.0  5.0 3  10  20  7.0 
9.1.3 Indoor/Outdoor Unit
*This illustration is for explanation 
purposes only. 
 The indoor unit will actually face a 
different way. 
16 
Wall
Indoor
Outdoor
15 mm
Sleeve for
tube ass’y
Approx. 5 - 7 mm
Bushing for tube ass’y
Putty or caulking compound
Ø 70 through hole
9.2 Indoor 
Unit 
9.2.1  How to Fix Installation Plate 
The mounting wall is strong and solid enough to prevent if from the vibration. 
 
The centre of installation plate should be at more 
than 450 mm at right and left of the wall. 
 
The distance from installation plate edge to 
ceiling should more than 120mm. 
 
From installation plate left edge to unit’s left side 
is 170 mm. 
 
From installation plate right edge to unit’s right 
side is 160 mm. 
 
B  
: For left side piping, piping connection for liquid should be about 105 mm from this line. 
 : 
For left side piping, piping connection for gas should be about 154 mm from this line. 
 
 
1  Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider 
using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with 
the thread and using a level gauge. 
2   Drill the piping plate hole with ø70 mm hole-core drill. 
z  Put measuring tape at position as shown in the diagram above. The hole centre is 
obtained by measuring the distance namely 178.5 mm and 161 mm for left and right 
hole respectively. 
z  Drill the piping plate hole at either the right or left and the hole should be slightly slanted 
to the outdoor side. 
 
9.2.2  To Drill a Hole in the Wall and Install a Sleeve of Piping 
Insert the piping sleeve to the hole. 
Fix the busing to the sleeve. 
Cut the sleeve until it extrudes about 15mm from the wall  
 
 
 
Finish by sealing the sleeve with putty or caulking compound at the final 
stage.  
 
 
Caution 
When the wall is hollow, please be sure to use the sleeve for tube 
ass’y to prevent dangers caused by mice biting the connecting 
cable. 