33 
12. Operation 
Control 
12.1 Basic Function 
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time 
passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating 
mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and 
performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by 
the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air 
temperature. 
12.1.1  Internal Setting Temperature 
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting 
processes. These shifting processes are depending on the air conditioner settings and the operation environment. 
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the 
electrical power is supplied to the unit. 
12.1.2 Cooling 
Operation 
12.1.2.1 Thermostat 
Control 
  Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5°C continue for 3 minutes. 
  Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > 
Compressor OFF point. 
12.1.3 Dry 
Operation 
12.1.3.1 Thermostat 
Control 
  Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.5°C continue for 3 minutes. 
  Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > 
Compressor OFF point. 
34 
12.1.4 Heating 
Operation 
12.1.4.1 Thermostat 
Control 
  Compressor is OFF when Intake Air Temperature - Internal Setting Temperature ≥ +2.0°C continue for 3 minutes. 
  Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < 
Compressor OFF point. 
12.1.5 Automatic 
Operation 
  This mode can be set using remote control and the operation is decided by remote control setting temperature, 
remote control operation mode, indoor intake air temperature and outdoor air temperature. 
  During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 
seconds to detect the indoor intake and outdoor air temperature. The operation mode is decided based on below 
chart. 
 
 
 
Every 30 minutes, the indoor and outdoor temperature is judged. 
The Auto Operation Mode shifting will take place whenever operation mode changed from Cooling/Dry to Heating or 
vice versa. 
35 
12.2  Indoor Fan Motor Operation 
12.2.1 CS-VE9NKE 
Indicates the changeable range using the remote control 
 
 Stop
SSLo
SLo 
Quiet
Lo- 
Lo 
Me- 
Me 
Hi 
SHi 
Fan speed: Manual 
--- 
--- 
(600)
--- 
640 
800 
960 
1110 
--- 
Normal (with programmed air) 
860 ~ 960 
Powerful  
1190 
Initial airflow 
Human search 
area control 
 740 
Powerful  
620  980 
COOL / C
O
OL R
ange 
Airflow stable 
Human search 
area control 
 
620  980 
Normal Cool 
dry O 
470 
 640 
Powerful  
640 
Initial airflow 
Human search 
area control 
 740 
Powerful  
510  980 
COOL DRY 
Ran
ge 
Fan 
speed: 
Auto 
Airflow stable 
Human search 
area control 
 
510  980 
Fan speed: Manual 
--- 
--- 
650 
--- 
720 
850 
980 
1110 
--- 
Normal  680  1020 
Powerful  
780  1060 
680  1110 
Initial airflow 
Human search 
area control 
 
680  1210 
Powerful  
850  980 
HEAT 
Fan 
speed: 
Auto 
Airflow stable 
Human search 
area control 
 
850  980 
Hot Dry 
 
640 
Fan speed: Manual 
--- 
600 
--- 
640 
800 
960 
1110 
--- 
Normal  
500 
Individual 
nanoe-G 
Fan speed: 
Auto 
Powerful  
1190 
Individual +8/10°C HEAT 
 
1110 
Odor Cut Shift 
Only for the COOL and DRY range 
 
Below Lo: No shifting                                                    Me and above: -90 
Lo and above, below Me and fan speed auto: -20 
* Lock detection: When the rotation speed of 2550rpm and above or below 50rpm is detected for 10 consecutive seconds during the feedback 
control, H19 is indicated (the TIMER indicator flashes) if normal rotation speed is not detected even after the retry is performed 7 times.  
* Refer to the attached list of “Indoor Unit Fan Operation Status” for the operations of the indoor unit fan while the thermostat is OFF. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
36 
(1) When the area control is in operation, the minimum rotation speed is limited as outlined below depending on the human position area. 
 
COOL & COOL DRY 
Same as the fan speed in the powerful mode. When the airflow is stable, the minimum rotation speed is limited to 
“1+2+3” as in the table below. 
HEAT 
Same as the fan speed in the powerful mode. In the range where the airflow is stable and the pipe temperature is high, 
the minimum rotation speed is limited to “1+3” as in the table below. 
FULL DRY 
The rotation speed is fixed at “1+2+3” as in the table below. 
 
Min. rotation speed for each field 
 
The minimum rotation speed is limited based on  
 
the following area information. 
 
 
 
 Corresponding 
Area 
Field 2 
LM, RM 
Field 3 
CM 
 
 
 
 
 
 
 
 
1
 
 
 COOL 
COOL 
DRY 
HEAT 
Field 
880 740 990 
Field 
840 700 970 
 
2
 During the ceiling airflow, a correction is performed 
for the minimum rotation speed as follows. 
 
In COOL or COOL 
DRY mode 
100 
 
3
 When making the air blow towards human 
body/object, a correction is performed for the minimum 
rotation speed as follows. 
 
In COOL or COOL 
DRY mode 
60 
 
Page of 127