Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual ▷ View online
125
Piping Length Characteristic Cooling
Condition
Room temperature: 27°C (DBT), 19°C (WBT)
Outdoor temperature: 35°C (DBT)
Fc : 48Hz
Room temperature: 27°C (DBT), 19°C (WBT)
Outdoor temperature: 35°C (DBT)
Fc : 48Hz
126
Heating Characteristic
Condition
Room temperature: 20°C (DBT)
Piping length: 5m
Fh : 49Hz
Room temperature: 20°C (DBT)
Piping length: 5m
Fh : 49Hz
127
Piping Length Characteristic Heating
Condition
Room temperature: 20°C (DBT)
Outdoor temperature: 7.0°C (DBT), 6.0°C (WBT)
Fh : 49Hz
Room temperature: 20°C (DBT)
Outdoor temperature: 7.0°C (DBT), 6.0°C (WBT)
Fh : 49Hz
128
17.2 Sensible Capacity Chart
CS-VE9NKE CU-VE9NKE
230V
Outdoor Temp. (ºC)
30 35 40
Indoor wet
bulb temp.
bulb temp.
TC SHC IP TC SHC IP TC SHC
IP
17.0ºC 2.47 1.51 0.44 2.31 1.44 0.48 2.15 1.39 0.51
19.0ºC
2.5
0.49
19.5ºC 2.73 1.58 0.45 2.56 1.51 0.49 2.38 1.46 0.52
22.0ºC 2.98 1.63 0.46 2.78 1.57 0.49 2.59 1.51 0.53
CS-VE12NKE CU-VE12NKE
230V
Outdoor Temp. (ºC)
30 35 40
Indoor wet
bulb temp.
bulb temp.
TC SHC IP TC SHC IP TC SHC
IP
17.0ºC 3.47 2.01 0.80 3.25 1.92 0.86 3.02 1.85 0.93
19.0ºC
3.5 2.0 0.88
19.5ºC 3.81 2.10 0.81 3.57 2.02 0.88 3.32 1.94 0.95
22.0ºC 4.16 2.18 0.83 3.88 2.09 0.90 3.61 2.02 0.96
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power
Indoor 27°C /19°C
Outdoor 35°C /24°C