Panasonic CS-VC75KE / CS-VC95KE / CS-VC125KE / CU-VC75KE / CU-VC95KE / CU-VC125KE Service Manual ▷ View online
Outdoor Unit
• To protect compressor from reverse
rotation when there is a instantaneous
power failure.
power failure.
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
However, it stops immediately with
remote control stop signal.
Overload Protector
• 2-Stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP
characteristic)
(Refer circuit diagram for OLP
characteristic)
Compressor Reverse Rotation
Protection Control
Protection Control
Outdoor Fan Operation Control
• Inner protector.
CU-VC75KE / CU-VC95KE
CU-VC125KE
5
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
3 Product Specifications
Unit
CS-VC75KE
CU-VC75KE
Cooling Capacity
kW
kcal/h
2.12
1820
Moisture Removal
l/h
Pint/h
1.4
3.0
3.0
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
5.5 (190)
—
Indoor Air (Me)
m
3
/min (cfm)
5.8 (200)
—
Indoor Air (Hi)
m
3
/min (cfm)
7.0 (250)
—
Indoor Air (SHi)
m
3
/min (cfm)
7.8 (280)
—
Noise Level
dB (A)
High 33, Low 26
High 44
Power level dB
High 46
High 59
Electrical Data
Input
W
620
Running Current
A
3.1
EER
W/W (kcal/hw)
3.42 (2.94)
Starting Current
A
13.0
Piping Connection Port
(Flare piping)
(Flare piping)
inch
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
(Flare piping)
inch
inch
inch
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
Drain
Hose
Hose
Inner diameter
mm
12
—
Length
m
0.7
—
Power Cord Length
Number of core-wire
Number of core-wire
m
2.0
3 (1.0 mm
2
)
—
—
—
Dimensions
Height
inch (mm)
10 - 31/32 (279)
18 - 29/32 (480)
Width
inch (mm)
31 - 15/32 (799)
30 - 23/32 (780)
Depth
inch (mm)
7 - 27/32 (199)
9 - 21/32 (245)
Net Weight
lb (kg)
20 (9.0)
64 (29)
Compressor
Type
—
Rotary (1 cylinder)
rolling piston type
Motor
Type
—
Induction (2-poles)
Rated
Output
W
—
550
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 30%
AES + Glass Fiber 16%
Motor
Type
Induction (4-poles)
Induction (6-poles)
Input
W
20.6
48.9
Rate
Output
W
10
20
Fan Speed
Low
rpm
820
—
Medium
rpm
855
—
High
rpm
1040
700
SuperHigh
rpm
1160
—
6
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
Heat Exchanger
Description
Evaporator
Condenser
Tube material
Copper
Copper
Fin material
Aluminium (Pre Coat)
Aluminium
Fin Type
Slit Fin
Louver Fin
Row / Stage
(Plate fin configuration, forced draft)
2 × 14
1 × 18
FPI
18
17
Size (W × H × L)
mm
614 × 294 × 25.4
856 × 457.2 × 22
Refrigerant Control Device
—
Capillary Tube
Refrigeration Oil
(c.c)
—
RB68A
(300)
Refrigerant (R410A)
g (oz)
—
655 (23.1)
Thermostat
Electronic Control
—
Protection Device
—
2 Stage Overload Protector
Capillary Tube
Length
mm
—
920
Flow Rate
l/min
—
9.5
Inner Diameter
mm
—
1.5
Air Filter
Material
Style
Style
(c.c)
P.P.
Honeycomb
—
Capacity Control
Capillary Tube
Compressor Capacitor
µF, VAC
—
15 µF, 440VAC
Fan Motor Capacitor
µF, VAC
1.5 µF, 400VAC
1.2 µF, 400VAC
•
Specifications are subject to change without notice for further improvement.
7
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
Unit
CS-VC95KE
CU-VC95KE
Cooling Capacity
kW
kcal/h
2.75
2,360
Moisture Removal
l/h
Pint/h
1.6
3.4
3.4
Power Source
Phase
V
Cycle
Single
230
50
Airflow Method
OUTLET
INTAKE
SIDE VIEW
TOP VIEW
Air Volume
Indoor Air (Lo)
m
3
/min (cfm)
6.3 (220)
—
Indoor Air (Me)
m
3
/min (cfm)
7.5 (260)
—
Indoor Air (Hi)
m
3
/min (cfm)
8.5 (300)
—
Indoor Air (SHi)
m
3
/min (cfm)
10.0 (350)
—
Noise Level
dB (A)
High 35, Low 26
High 46
Power level dB
High 48
High 61
Electrical Data
Input
W
820
Running Current
A
3.6
EER
W/W (kcal/hw)
3.35 (2.88)
Starting Current
A
20.0
Piping Connection Port
(Flare piping)
(Flare piping)
inch
inch
inch
G ; Half Union 3/8”
L ; Half Union 1/4”
G ; 3-way valve 3/8”
L ; 2-way valve 1/4”
Pipe Size
(Flare piping)
(Flare piping)
inch
inch
inch
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
G ; (gas side) 3/8”
L ; (liquid side) 1/4”
Drain
Hose
Hose
Inner diameter
mm
12
—
Length
m
0.7
—
Power Cord Length
Number of core-wire
Number of core-wire
m
2.0
3 (1.0 mm
2
)
—
—
—
Dimensions
Height
inch (mm)
10 - 31/32 (279)
18 - 29/32 (480)
Width
inch (mm)
31 - 15/32 (799)
30 - 23/32 (780)
Depth
inch (mm)
7 - 27/32 (199)
9 - 21/32 (245)
Net Weight
lb (kg)
20 (9.0)
68 (31)
Compressor
Type
—
Rotary (1 cylinder)
rolling piston type
Motor
Type
—
Induction (2-poles)
Rated
Output
W
—
700
Air Circulation
Type
Cross-flow Fan
Propeller Fan
Material
AS + Glass Fiber 30%
AES + Glass Fiber 16%
Motor
Type
Induction (4-poles)
Induction (6-poles)
Input
W
28.3
48.9
Rate
Output
W
15
20
Fan Speed
Low
rpm
830
—
Medium
rpm
995
—
High
rpm
1125
700
SuperHigh
rpm
1330
—
8
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE