8.8. Random Auto Restart Control
  • 
If there is a power failure, operation will be automatically restarted after 3 to 5 1/2 minutes when the power is resumed.
It will start with previous operation mode and airflow direction.
  • 
Restart time is decided randomly using 4 parameter:-
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
  • 
Auto Restart Control is not available when Timer or Sleep Mode is set.
  • 
This control can be omitted by open the circuit of JX1. (Refer Circuit Diagram)
8.9. Indoor Fan Speed Control
  • 
Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the table.
  • 
Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button.
Random Fan Speed
The fan is turning at pattern A or B or C randomly, for an interval of 10” each during Random Fan Speed.
25
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
Airflow Direction Auto-Control
  • 
When set a Airflow Direction Auto-Control with remote
control, the louver swings up and down as shown in the
diagram.
  • 
The louver does not swing when the Indoor Fan stops
during operation.
  • 
When stopped with remote control, the discharge vent is
closed with the louver.
Airflow Direction manual Control
  • 
When the manual Airflow Direction Selection Button is
pressed, the automatic airflow is released and the airflow
direction louver move up and down in the range shown in
the diagram.
The louver can be adjusted by pressing the button to the
desired louver position.
  • 
When the remote control is used to stop the operation, the
discharge vent is closed with airflow direction louver.
8.10. Airflow Direction Control
1. There is no swinging while indoor fan is stopped during Cooling and Soft Dry operation.
2. In Air Circulation operation, when the intake air temperature reaches set temperature, the airflow direction is changed from upper limit to
lower limit. When the intake air temperature falls to 2°C lower than set temperature, the airflow direction is changed from lower limit to
upper limit.
8.11. Delay ON Timer Control
  • 
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
  • 
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
  • 
For Automatic mode, the indoor fan will operate at Lo speed for 20 seconds, 15 minutes before the set time to detect the intake
air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.12. Remote Control Signal Receiving Sound
  • 
Long beep sound will be heard when:-
  − 
Stopping the Air Conditioner using ON/OFF switch.
  − 
Stopping the Sleep Mode.
  − 
Stopping the Powerful Mode.
  − 
Stopping the Economy Mode.
  • 
Short beep sound will be heard for others.
  • 
To switch off the beep sound:-
Press the “Automatic Operation Button” continuously for 10 seconds or more (“beep” “beep” will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the “Automatic Operation Button” has been pressed the Automatic cooling operation will be activated.
If you do not require this operation, you may change it by using the remote control.
26
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
9 Operating Instructions
Do not install, remove and reinstall the unit yourself.
Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist
for the installation work.
SAFETY PRECAUTIONS
Before operating, please read the following “Safety Precautions” carefully.
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is
classified as follows :
The instructions to be followed are classified by the following symbols :
!
  Warning
!
  Caution
This symbol (with a white background) denotes
an action that is PROHIBITED.
!
  Warning
This sign warns of death or serious injury.
This room air conditioner must be earthed.
Improper grounding could cause
electric shock.
Do not install the unit in a place where there
may be explosive gas leaks.
Gas leaks near the unit could cause
fires.
OFF
These symbols (with a black background)
denote actions that are COMPULSORY.
!
  Caution
This sign warns of damage to property.
Installation Precautions
Ensure that the drainage piping is connected
properly.
Otherwise, water will leak out.
27
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
Do not share outlet.
POWER
ECONOMY
POWERFUL
SLEEP
TIMER
!
  Warning
This sign warns of death or
serious injury.
Do not insert plug to
operate the unit.
Do not pull out plug to
stop the unit.
Plug in properly.
Do not operate with
wet hands.
Operation Precautions
Use specified power
cord.
Do not damage or
modify the power cord.
If abnormal condition (burnt smell, etc) occurs, switch off
and unplug the power supply.
OFF
Do not repair by
yourself.
Do not exposed directly to cool air
for a long period.
Do not insert finger or other objects into the indoor or
outdoor units.
28
CS-VC75KE CU-VC75KE / CS-VC95KE CU-VC95KE / CS-VC125KE CU-VC125KE
Page of 101
Display

Click on the first or last page to see other CS-VC75KE / CS-VC95KE / CS-VC125KE / CU-VC75KE / CU-VC95KE / CU-VC125KE service manuals if exist.