Disassembly of Indoor Fan Motor
 1. Remove the electronic controller and the terminal board.
 2. Untighten two fixing screws of the fan motor, release
two tabs and remove the discharge grille. (Fig 6Fig 7)
 3. Remove the indoor fan motor. (Fig 8Fig 9 )
Fig 6
Fig 7
Fig 8
Fig 9
69
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
O
O
O
Disassembly of cross flow fan
 1. Remove the indoor fan motor and heat exchanger.
 2. Pull out the bearing on the left side. (Fig 10 )
 3. Take out the cross flow fan.(Fig 11 )
 4. Indoor electronic controller.(Fig 12 Fig 13 )
Fig 10
Fig 11
Fig 12
Fig 13
70
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
O
O
O
Disassembly of Outdoor Unit
 1. Remove the front panel of the outdoor unit. (Fig 14 )
 2. Release
three
fixing
screws
of
C-BOX
and
all
connectors and the C-BOX can be replaced. (Fig 15 ,
Fig 16 Fig 17 Fig 18 )
Fig 14
Fig 15
Fig 16
Fig 17
71
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
O
O
O
Remote control reset
If the display is chaotic or can not be adjusted, use a pin to
gently press RESET button to reset the remote control to
the original set by manufacturer.(Fig 19 )