7.7. Automatic Operation
If the Auto operation mode is selected, the operation mode will be judged by set temperature on remote control, intake air
temperature and outdoor air temperature.
During operating mode judgement, indoor fan runs at low fan speed and outdoor fan runs in the purpose of detecting the intake
air temperature and outdoor air temperature (for 20 seconds)
Set Temp on
Remote Control
16, 17, 18
+10
-3
-5
19, 20, 21, 22
+8
-3
-7
23, 24, 25, 26
+7
-3
-7
27, 28, 29, 30
+6
-3
-8
If the operation mode changed,
,
,
will change as follow:
Cooling /Soft Dry
→ Heating Operation: -2°C
Heating
→ Cooling /Soft Dry Operation: +2°C
45
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
7.8. Delayed ON-Timer Control
Delay ON-Timer can be set using remote controller, the unit with timer set will start operate earlier than the setting timer. This
is to provide a comfortable environment when reaching the set On time.
Seventy minutes before the set time for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor
start operate for 20 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the
operation mode.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
Timer Signal Receiving Sound During Operation
Operation
Sound
Timer LED
Timer Setting
ON Timer Set
OFF
Beep-
ON
Valid
OFF Timer Set
ON
Beep-
ON
Valid
ON-OFF Timer Set
OFF
Beep-
ON
Valid
OFF-ON Timer Set
ON
Beep-
ON
Valid
Timer Signal Receiving Sound During Operation
Operation
Sound
Timer LED
Timer Setting
ON Timer Set
OFF
Beep-
ON
Valid
OFF Timer Set
ON
Beep-
ON
Valid
ON-OFF Timer Set
OFF
Beep-
ON
Valid
OFF-ON Timer Set
ON
Beep-
ON
Valid
7.9. Auto Restart Control
If there is a power failure, operation will be automatically restarted after 3-4 minutes when the power is resumed. It will start with
previous operation mode and airflow direction.
46
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
8 Installation Instructions
Required tools for Installation Works
1.
Philips screw driver
5.
Spanner
9.
Gas leak detector
13. Multimeter
2.
Level gauge
6.
Pipe cutter
10. Measuring tape
14. Torque wrench
18 N.m (1.8 kgf.m)
42 N.m (4.2 kgf.m)
55 N.m (5.5 kgf.m)
3.
Electric drill, hole core drill
(ø70 mm)
7.
Reamer
11. Thermometer
15. Vacuum pump
4.
Hexagonal wrench (4 mm)
8.
Knife
12. Megameter
16. Gauge manifold
8.1. Safety Precautions
    • 
• 
• 
• Read the following “SAFETY PRECAUTIONS” carefully before installation.
    • 
• 
• 
• Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
for the model to be installed.
    • 
• 
• 
• The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
    • 
• 
• 
• Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1.
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
2.
Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3.
Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
electrical shock.
4.
Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
5.
For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6.
Use the specified cable (1.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7.
Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
cause heat-up at connection point of terminal, fire or electrical shock.
8.
When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
9.
When connecting the piping, do not allow air or any substances other than the specified refrigerant (R410A) to enter the
refrigeration cycle. Otherwise, this may lower the capacity, cause abnormally high pressure in the refrigeration cycle, and
possibly result in explosion and injury.
10.
    • 
• 
• 
• When connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause
abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only
R410A materials.
    • 
• 
• 
• Thickness of copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8
mm.
    • 
• 
• 
• It is desirable that the amount of residual oil is less than 40 mg/10 m.
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or electrical shock.
47
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
1.
The equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
1. Selection of the installation location.
Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
2.
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the following method.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
 1. 
Power supply connection to the receptacle using a power plug.
Use an approved 15A/16A power plug with earth pin for the connection to the socket.
 2. 
Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for the permanent
connection. It must be a double pole switch with a minimum 3 mm contact gap.
3.
Do not release refrigerant.
Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
4.
Installation work.
It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
48
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Page of 84