Panasonic CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE Service Manual ▷ View online
1
Functions
2
2
Product Specifications
5
3
Dimensions
9
4
Refrigeration Cycle Diagram
11
5
Block Diagram
12
6
Wiring Diagram
13
7
Operation Details
15
8
Installation Instructions
47
9
Installation and Servicing Air Conditioner Using R410A
57
CS-PE9CKE
CU-PE9CKE
CS-PE12CKE
CU-PE12CKE
CU-PE9CKE
CS-PE12CKE
CU-PE12CKE
10 Disassembly of the parts
68
11 Trouble-shooting guide
73
12 Technical Data
75
13 Exploded View
76
14 Replacement Parts List
77
15 Exploded View
78
16 Replacement Parts List
79
17 Electronic Circuit Diagram
80
18 Electronic Circuit Diagram (Remote Control)
84
Room Air Conditioners
CONTENTS
Page
Page
Order No. GMAC0401003C2
1 Functions
Operation START/STOP
Operation Mode Selection
Automatic
Operation
Heating Mode Operation
Cooling Mode Operation
Soft Dry Mode Operation
Mode
Indoor Fan Speed Selection
Medium Speed
Low Speed
Supper Low Speed
Automatic Speed
Airflow Direction Control
Auto Airflow Direction
Airflow Direction Manual Control
Room Temperature Setting
Temperature Setting(16
to 30
)
Auto Operation
Check Point
Self diagnosis function
Reset Point
Clear memory data
Remote Control
OFF/ON
MODE
FAN
SPEED
SPEED
High Speed
Supper High Speed
AIR
SWING
SWING
TEMP
CHECK
RESET
Error Reset Point
To reset the indoor unit.
ERROR
RESET
RESET
2
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Indoor Unit
Automatic Operation Switch
Press for <5s to run Automatic Operation.
(Used when the remote control cannot be
used.)
Press continuously for 5s and < 8s to run
Forced Cooling Operation.
Press continuously for 8s and <11s to run
Forced Heating Operation.
Press continuously for 11s and <16s to change
different remote controlling setting(A
B)
Mode.
Press continuously for 16s and < 21s to switch
OFF/ON Remote Control receiving Sound or
H14 Abnormality Detection Mode.
Operation Indication Lamps
Operation (green)
Timer(orange)
Iights up in operation
Blinks during Test
Run operation and
determining Auto
Operation mode
Timer in operation
Operation Mode
Heating/Cooling/Soft Dry Operation/
Auto Operation
Time Delay Safety Control
The unit will restart operation 3-4
minutes after each pause.
Auto Restart Control
Operation is restarted automatically at
previous mode after a power failure.
Anti-freezing Control for the Evaporator
Cooling or Soft Dry Operation
Supper Low , Low , Medium, High, Supper
High and Auto Fan Speed can be selected.
Deodorization
control is available for
cooling and soft dry operation.
Indoor Fan Speed Control
Automatic Airflow Direction Control
The louver automatically swings up and down
Airflow Direction Manual Control
Airflow Direction Control
Anti-fog Discharge Control
Cooling or Soft Dry Operation
AUTO
OFF/ON
OFF/ON
3
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE
Outdoor Unit
Time Delay Safety Control
30 Seconds Forced Operation Control
Anti-freezing operation for outdoor unit(during
Heating Mode Operation only)
Temperature of the condenser is tested by TRS.
Deicing Control
Outdoor Fan Motor Control
Panasonic
IPM(Power Transistor)
Overheating Protection Control
Total Running Current Control
DC Peak Current Control
4
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE